Web Analytics Made Easy - StatCounter

Direct Ophthalmoscope Tenders

Get complete information related to latest Direct Ophthalmoscope Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Direct Ophthalmoscope Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Direct Ophthalmoscope Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45418510 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For corrigendum : online tender for the quantity contract of various ophthalmic equipment to be supplied and installed at various hospitals of government of madhya pradesh - equipment, ophthalmic operating microscope, fundus camera for dr screening, direct ophthalmoscope

corporations/Associations/Others

CTN :43777369 Due date: 31 Jul, 202631 Jul, 2026 3.20 Crore
Tender For corrigendum : supply of opthalmology items : : -direct ophthalmoscope , schiotz tonometer , indirect ophthalmoscope , slit lamp , a-scan biometer , streak retinoscope , keratometer

CTN :45582493 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of electronic baby weighing scale , pediatric stethoscope , head circumference tape , indirect ophthalmoscope , pediatric diagnostic kit , tuning fork set , ent diagnostic instrument set , torch penlight , direct ophthalmoscope , lea symbol test set , dassi kit , vineland social maturity scale , developmental screening test , ddst ii , stanford binet test , therapy balls , therapy mattress , bolsters , prone wedge , balance board , kaye walker , bolster swing , wooden bench , therapy toys , parallel bar , exercise cycle , pin spot mirror ball , mirror ball motor , led mirror ball , fireball light , sensory swings set , real size animal toys

CTN :45559574 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For supply of ray viewing bo , otoscope , tongue depressor , direct ophthalmoscope , illuminated vision testing drum , trial lens sets with trial frames , snellenand near vision charts , epilation forceps , ear speculam , ear syringe , jobson horne probe , tuning fork 512 hz , adult laryngoscope , adult ambu bags , airways all sizes , peadiatric laryngoscope , peadiatric ambu bag , et tubes all sizes , drug trolley , dressing trolley , instrument trolley , cheetles forcep , allies forceps , sponge holder , artery forceps , cuscos speculum , anterior vaginal wall retractor , kidney tray , episiotomy scissors , straight scissors , sims speculum , centrifuge machine , naubers chember , bp apparatus digital , torch , stethoscope , peak flow meter , measuring tape , thermometer , foetoscope , digital weighing machine , digital infant weighing scale , stadiometer , dressing trays , dressing drums , eamination lamp , cheatles forceps , nasal speculum , dressing forceps , digital scope , led head lamp , eustachian catheter , dental eplorer , dental mouth mirror , tweezer intradental brush , cord clamp , cord cutting scissors , episiotomy scissor , oygen cylinder accessories flow meter key mask , mouth gag , nebulizer , foot step double , iv stand , wall clock , refrigerator , autoclave strips , adult weight machine , aed auomated eternal defibrllator , bowl for antiseptic solution , delivery tray with artery forcep , emergency medicine tray , fetal doppler , instrument tray , mucos etractor , vaccine carrier regular , ice pack regular , slit lamp , head light , noise maker , autoclave single , fogging machine , colorimeter , app and headphone for app based audiometery , foot suction machine , office table , doctor chair revolving , patient stool , eamination table , attendant chair , screen separators with stand , alcohol swab , bp apparatus mercury , gluco meter strips , rack slotted angle , pulse oymeter , puncture proof bo sharp desposable container , needle holder , point - of - care hemoglobinometer (q2) , hemoglobin test strips (q2) , blood glucose meter - glucometer (v2) (q2) , blood lancets (q2)

Central Government/Public Sector

CTN :45410904 Due date: 06 Jun, 202606 Jun, 2026 NA
Tender For supply of consumable items amplaz diagnostic catheter , amplaz diagnostic catheter , amplaz guiding catheter , amplaz guiding catheter , ebu (extra backup cathetor) guiding catheter , ebu (extra backup cathetor) guiding catheter , ebu (extra backup cathetor) guiding catheter , ebu (extra backup cathetor) guiding catheter , ebu (extra backup cathetor) guiding catheter , erii (extra backup cathetor) guiding catheter , ebu (exu e gackup cathetor) guiding catheter , ebu (extra backup cathetor) guiding catheter , ebu (extra backup cathetor) guiding catheter , ebu (extra backup cathetor) guiding catheter , ebu (extra backup cathetor) guiding catheter , ebu (extra backup cathetor) guiding catheter , judkins diagnostic catheter , double lumen micro catheter , diagnosus catheter all curve , guide catheter all curve , guide catheter for ptca , guide catheter for ptca , guide catheter for ptca , micro catheter , multipurpose catheter , thrombosuction catheter , ballon flotation catheter , routine diagnostic gulde wire , routine diagnostic guide wire , extension guide wire , exchange guide wire , exchange guide wire , guide extension catheter , guide extension catheter , terumo guide wire , ptca guide wire , ptca guide wire , ptca guide wire , ptca guide wire , ptca guide wire , pica guide wire , ptca guide wire , pica guide wire , ptca guid wire , ptca guide wire , cto guide wire of different tip load , radial sheath , radial sheath , radial sheath , femoral sheath , amplaz sheath , amplaz sheath , amplaz sheath , radial puncture needle , femoral puncture needle , femoral dialator , coronary ballon , coronary ballon , coronary ballon , ballon of size variour lengths , s.c dallon of size varinur lengths , d.c ballon various size , cardiac drug cluting (des) stent (silrolimus) , cardiac drug-eluting (des) stent (everoliumus) , cardiac drug-eluting (des) stent (zotarolimus) , covered stent , cardiac snare for catheter retrieval , cardiac stent (brs) bio ressorbable scaffold , steerable introducer sheath for one kit , ntroducer system for asd/vsd/pda delivery kit for one kit , asd closure device set , jsd closure device set , da closure device set

CTN :45324155 Due date: 09 Jun, 202609 Jun, 2026 33
Tender For procurement of medical equipment under kkrdb funds. 2025-26 - bulls eye lamps., motor with drill and hand piece., mastoidectomy set., water filters., cbcmachines., all in onecomputers., domestic fridgee., para 5 monitor., c-arm machines., chalazion sets., direct ophthalmoscope do., cataract sets, ar machine with keratometer., ent microscope., operating ophtholmic microscope.

Central Government/Public Sector

CTN :45335075 Due date: 05 Jun, 202605 Jun, 2026 NA
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapidexchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of thestent to a major government institute. unit:no [ warranty period: 30 months after the date of delivery ] ]

CTN :45146882 Due date: 25 May, 202625 May, 2026 1.00 Crore
Tender For empanelment for the supply of cathlab items on running contract basis under kasp and other schemes of this hospital - coronary stents, des,everolimus,fda/dcgi/ce approved platinum chromium platform,polyvinylidene fluride-hexafluropropyline pvdf-hfp polymer-stent lengths8,12,16,24,28,32. stent diameter 2.25*,2.50,2.75,3.00,3.50,4.00.struct thickness 81/86 microns.nominal pressure - 11 atm,rated burst pressure 16-18 atm, des,everolimus,fda/ approved platinum chromium platform,polyvinylidene fluoride-hexafluropropylene(pvdf-hfp)polymer, des,everolimus,fda/dcgi/ce/ approved platinum chromium platform,bioabsorbable polymer plga, everolimus eluting platinum chromium stent system, des, everolimus, l 605 cobalt chromium with hybrid cell design , strut thickness- 65microns, polymer- plga diameter- 2.25, 2.5, 2.75, 3.0, 3.5,4. length- 10,13,15,18,20,24, 28, 32,36,40, 42, 44, des, everolimus, cobalt chromium strut thickness - 63 microns . diameter- 2.25,2.5,2.75,3,3.5,4. length- 8,10,13,15,18,20,24,28,32,36,40,42,44. elutes 80% of drugs along with re plga polymer in the first 20 days, dcgi approved everolimus drug eluting 65 micron strut thickness with 3 micron plla&plga. a unique proprietory coating technology basedbiodegradable polymer stent with open cell designed and flexia finished technology based cobalt chromium l605 stent.a designed for optimal strength, flexibility ,trackablity ,side branch supported,bifurcation supported and high radial strength and optimal radiopacity and excellent vessel supported stent with revers alternative link design(ral) stent, with length from 8 mm to 52 mm and diameter from 2.25 mm to 4.50 mm, ce approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., ce approved sirolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., only dcgi approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 deg

CTN :45004704 Due date: 27 May, 202627 May, 2026 28.76 Lacs
Tender For bid to ras bid to ras bid to ras bid to ras corrigendum : supply of drug and pharmaceutical items - sitagliptin 50mg tab + metformin 1000mg tab , tab sodium valproate 500mg cr (sodium valproate 333mg + valproic acid 145mg) , tacrolimus 0.5mg tab , tacrolimus 1mg tab , tacrolimus 2mg tab , tamsulin 0.4mg + dutasteride 5mg tab , taurine 500mg + acetylcystine 150mg tab , telmisartan 20mg tab , telmisartan 40mg + amlodipine 5mg tab , telmisartan 40mg +chlorthalidone 12.5mg tab , telmisartan 40mg + hydrochlorthiazide 12.5mg tab , thyroxine 50mcg tab , tofacitinib 11mg tab , torsemide 10mg tab , torsemide 20mg tab , ursodexycholic acid 300mg tab (udiliv ) , vericiguat 2.5mg tab , vildagliptin 50mg tab , vit a, d, e, c, b1, b12, folic acid, biotin (menopace) tab , cetrizine 5mg + paracetamol 325mg + phenylephrine hcl 5mg (cold plus) tab , fungal diastace 100mg + papain 60mg + activated charcol 75 mg (unienzyme) tab , inj darbepoetin 60mg , inj erythropoietin recombinant human 2000 iu , inj erythropoietin recombinant human 6000 iu , inj human insulin glargine 300iu/ml, 3ml cartridge , inj rabipur vaccine 1ml (cell culture rabies vaccine vial of 1 ml ) , human insulin analogue aspart premix 50 per insulin / 50 per insulin protamine aspart suspension 100 iu/ml (monocomponent insulin, recombinant dna origin) 3 ml pfp / pfs (novomix 50) inj , influenza vaccine (vaxigrip) , insulin lispro biphasic 50% (50% insulin lispro and 50% insuline lispro protamine suspension 100iu/ml,3ml cart) humalog mix 50 3ml cart , syp sucralfate 1gm/5ml bott of 200ml , syp antacid gel 170ml (digene gel) , bromhexine (2mg) + guaifenesin (50mg) + menthol (1mg) + terbutaline (1.25mg) syrup , bromhexine 100ml syp , cremaffin (liquid paraffin 1.25mg+ magnesium hydroxide 3.75mg+ sodium picosulphate 3.3mg) 170ml syp , guaiphenesin ip 100mg + dextramethorphan 10mg + phenylepherine 5mg chlorpheniramine 4mg each 5ml sugar free syp bott of 100ml , ketoconazole (2% w/v) lotion 75ml , mometasone 0.1% tube of 10 gm oint , mupirocin 2% tube of 5 gm oint , oestrogen cream (concentration 0.06% to 0.1% w/w) (tube of 15 to 50 gm) , oin clobetasol + salicylic acid (dipsalic ) , tacrolimus 0.1 % ointment, tube of 10 gm , tacrolimus oint( 0.03% ) 20 gm tube , (linseed oil + diclofenac+methyl salicylate + menthol gel) , amorolfine 5% nail lacquer, bott of 2.5ml , calamine lotion 100ml , chlorhexidine mouth wash 2% bott of 100 ml , clobetasol 0.05%w/w + salicylic acid 3.5% w/w cream, tube of 20gm , diclofenac spray bottle of 40 gm , fourderm cream chlorhexidine gluconate (0.20%), clobetasol topical (0.05%), miconazole topical (2%), neomycin topical (0.5%) 30 gm , delivery system for salmeterol + fluticasone rotacaps with pin puncture , formoterol (6mcg) + budesonide (400mcg) rotacap , inh formoterol 6 mcg+tiotropium 9mcg mdi (duova) , inh indacaterol 110 mcg + glycopyrrolate 50 mcg , inh salmeterol 25mcg + fluticasone 125mcg 120 mdi (seroflow) , beclomethasone dipropionate 50 mcg+levosalbutamol 50 mcg mdi (aerocort inhaler) , mdi levosalbutamol 50 mcg 200 md , nasal spray calcitonin 200iu , salbutamol 200 mdi (each metered dose supplies 100mcg of salbutamol) mdi , tiotropium (18mcg) rotacap , tiotropium bromide 9 mcg, 120 metered doses/unit, inhalerotacap

Central Government/Public Sector

CTN :45254443 Due date: 03 Jun, 202603 Jun, 2026 NA
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus, everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval shouldbe enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent toa major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
 Loading, Please wait...

Connect us via What's Up