Get complete information related to latest Disc Insulator Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Disc Insulator Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Disc Insulator Scrap Tenders.
Tender For supply of 33kv (e)grade (3 core 300sqmm) ht cable stranded compacted circular aluminiumconductor screen semi conducting compound xlpe insulated, insulation screening with extruded semiconducting compound in combination with copper tape, cores laid up inner sheath of pvc, galvanized steel flat string armored and overall pvc sheathed cable conforming to is:7098 pt-ii pool with latest amendment. (material to be procured by pvvnl approved vendors). [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply of harness of lhb eog non -ac lscn coaches with fdb on cabin side area only, as per drawing: edts452, packing instruction: cable harness: complete one coach set cable harness to be protected with biodegradable transparent polythene sheet and packed ina wooden box. soft eco-friendly packing material hay,straw, etc be provided inside the wooden box to protect any damage to cable insulation while packing/unpacking.bottom frame to be made of wooden planks 20mm thick & should have support of atleast 3 wooden battons of size 100x100mm of suitable length to facilitate lifting by fork lifter. rigid pvc conduit supplied loose along with harness should be packed as perinstructions .the material used for product packaging shall be eco-friendly.a list should be pasted on each packing showing order no ,pl no, description of the item, drg.no/spec.no, qty , firm's name &address and date of despatch etc. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of harness of lhb eog non -ac lscn coaches with fdb on cabin side area only, as per drawing: edts452, packing instruction: cable harness: complete one coach set cable harness to be protected with biodegradable transparent polythene sheet and packed ina wooden box. soft eco-friendly packing material hay,straw, etc be provided inside the wooden box to protect any damage to cable insulation while packing/unpacking.bottom frame to be made of wooden planks 20mm thick & should have support of atleast 3 wooden battons of size 100x100mm of suitable length to facilitate lifting by fork lifter. rigid pvc conduit supplied loose along with harness should be packed as perinstructions .the material used for product packaging shall be eco-friendly.a list should be pasted on each packing showing order no ,pl no, description of the item, drg.no/spec.no, qty , firm's name &address and date of despatch etc. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of harness for hog compliant lhb eog non ac lslrd(31 seater) coaches., as perdrawing: edts410,rev-a, packing instruction: cable harness: complete one coach set cable harness to be protected with biodegradable transparent polythene sheet and packed ina wooden box. soft eco-friendly packing material hay,straw, etc be provided inside the wooden box to protect any damage to cable insulation while packing/unpacking.bottom frame to be made of wooden planks 20mm thick & should have support of atleast 3 wooden battons of size 100x100mm of suitable length to facilitate lifting by fork lifter. rigid pvc conduit supplied loose along with harness should be packed as perinstructions .the material used for product packaging shall be eco-friendly.a list should be pasted on each packing showing order no ,pl no, description of the item, drg.no/spec.no, qty , firm's name &address and date of despatch etc. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply of harness for hog compliant lhb eog non ac lslrd(31 seater) coaches., as perdrawing: edts410,rev-a, packing instruction: cable harness: complete one coach set cable harness to be protected with biodegradable transparent polythene sheet and packed ina wooden box. soft eco-friendly packing material hay,straw, etc be provided inside the wooden box to protect any damage to cable insulation while packing/unpacking.bottom frame to be made of wooden planks 20mm thick & should have support of atleast 3 wooden battons of size 100x100mm of suitable length to facilitate lifting by fork lifter. rigid pvc conduit supplied loose along with harness should be packed as perinstructions .the material used for product packaging shall be eco-friendly.a list should be pasted on each packing showing order no ,pl no, description of the item, drg.no/spec.no, qty , firm's name &address and date of despatch etc. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : supply of isi marked 11 kv (e) grade 3core 240 sq.mm. ) ht cable stranded compacted circular aluminium conductor screen semi conducting compound xlpe insulated, insulation screening with extruded semiconducting compound in combination with copper tape, cores laid up inner sheath of pvc, galvanized steel flat string armored and overall pvc sheathed cable confirming to is: 7098(part 2):1988 with amendment number 1 and 2 and 3 reaffirmed 2005 & improved fire retardant features as category c2 fr-lsh type. (3) cable is not use for mines & low voltage application. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For roll of pvc tape f.r electrical in insulation tap {thickness 0.125mm, width 1.80 cm, length 06 mtr.} is:7809 isi marked, make- anchor, steel grip, capcond or equivalent. (equal qty in red, yellow, blue & black) expiry should not less than 10 month from the date of supply. [ warranty period:30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]
Tender For supply of insulation monitoring relay, 415v ac, 3 phase,neutralisolated, voltage range 0-500 v ac, insulation measuring range-10 k ohm to 150 k ohm, control voltage: 24 - 240 v ac/dc,asper page no: 39, s.no.63, item code: a2 and place of installation s1a7, of bill of material of rdso spec. no. rdso/pe/spec ac/0184-2015(rev.1), used for insulation control 415 v of lhb type ac coaches, confirming to rdso spec. no.rdso/pe/spec/ac-0184-2015 (rev.1), suitable for lhb type ac coaches switch board cabinet (s1a07). accepted make: abb:cm-iws.2s.or contrel make ir 470ly-21a, ri r138 orschneider make- vigil ohm/imd-im10 or siemens make- 3ug4581-1aw31 or dold make model no il5880 or woka make or bender make. supplier should provide oem authorization or dealership certificate or proof of purchase from oem or oem authorized vendor along with supply. supplier to ensure that the offered product is supplied with valid oem`s warranty certificate. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif