Get complete information related to latest Disc Insulator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Disc Insulator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Disc Insulator Tenders.
Tender For replacement of 132kv busbar-1 of twin zebra acsr conductor and porcelain discinsulators of 9no. sections with twin moose acsr conductor, src insulators along with jack bus and connecting jumpers of 132kv feeders, 220/132kv, 132/33kv ptrs and bus coupler at 220/132/33kv gajuwaka ss under rmi works for f.y. 2023-24.
Tender For supply of 11kv line spares pertaining to colony electrical maintenance mtps dvc - p g clamp suitable for dog conductor , lighting arrestor 10 ka, 12 kv , 11 kv, 400 a, 16ka, 3-pole air break gang operated isolator with drop out fuse suitable for vertical mounting - complete set , 11kv pin insulator - 5kn with pin and hardwares , drop out fuse 11kv 25amp. , drop out fuse 11kv 40amp. , 11kv discinsulator -45 kn with hardwares , complete galvanised stay set along with accessories - turn buckle, stay clamps, etc. , galvanised iron stay wire, 7by8 swg
Tender For providing of custom bid for services - replacement of 12 sets of old string discinsulators pertaining to swing bus of main bus #1&2 zone of 400kv switchyard, dvc, ktps
Tender For for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, discinsulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuse set 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by contractor), la
Tender For deposit work in the area of edsd-laxminagar under edd-laxminagar, mathura - carriage of 8.5 mtr long pcc pole from 132 kv store center mathura to site of work through the kacha and pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-70 kms.), carriage of 9/11 mtr long st pole from 132 kv store center mathura to site of work through the kacha and pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-70 kms.), carriage of 16 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 25 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 63/100 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 250 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 11 kv xlpe cable size 3x70/3x120 sq.mm. cable form store center mathura/agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends., carriage of 11 kv xlpe cable size 3x185/3x300 sq.mm. cable form store center mathura/agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends., carriage of line material i.e. conductor, g.i. wire tpmo stay rod, discinsulator, cross arm, angle channel and other required material from store center at 132 kv substation mathura to the site of work including loading and unloading of material at both ends., erection of single pole structure 8.5 mtrs on pcc pole by digging of pits fitting of all relevant accessories as per respo norms., erection of single pole structure 9/11 mtrs on st pole by digging of pits fitting of all relevant accessories as per respo norms., erection of double pole structure 8.5 mtrs on pcc pole by digging of pits fitting of all relevant accessories as per respo norms., erection of double pole structure 9/11 mtrs on st pole by digging of pits fitting of all relevant accessories as per respo norms., installation of stay set with grouting and nuzzling etc. as per respo drawing along with all routine material to be used for such works., earthing of poles by fixing earthing rods and binding with earth wire as per standard norms including cost of labour t&p and required material for such work., laying, sagging stringing and binding of acsr weasel conductor on the erected pcc pole/stp including jumpering as per respo manual., laying, sagging stringing and binding of acsr dog conductor on the erected pcc pole/stp including jumpering as per respo manual., laying, sagging stringing and binding of arial bunch conductor on the erected pcc pole/stp including jumpering as per respo manual., laying, sagging stringing and binding of lt pvc cable on the erected pcc pole/stp including jumpering as per respo manual., laying of 11 kv xlpe cable size 3x70/3x120 sq.mm. in the trench/g.i pipe/hdpe pipe and re-dressing of trench after laying of xlpe cable for proper completion of work as per direction of supervising engineer., laying of 11 kv xlpe cable size 3x185/3x300 sq.mm. in the trench/g.i pipe/hdpe pipe and re-dressing of trench after laying of xlpe cable for proper completion of work as per direction of supervising engineer., filing of cable box as suitable size as per direction of supervising engineer., filing of straight through as suitable size as per direction of supervising engineer., chopping of tree branches to clear the route properly., mounting of 16 kva transformer on the double pole/plinth struct
Tender For deposit work in the area of edsd laxminagar under edd-laxminagar, mathura - carriage of 8.5 mtr long pcc pole from 132 kv store center mathura to site of work through the kacha and pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-70 kms.), carriage of 9/11 mtr long st pole from 132 kv store center mathura to site of work through the kacha and pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, t&p, carrier etc. required for proper completion of work.(distance 00-70 kms.), carriage of 16 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 25 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 63/100 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 250 kva transformer from store centre, mathura to pit site with loading & unloading at both ends, carriage of 11 kv xlpe cable size 3x70/3x120 sq.mm. cable form store center mathura/agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends., carriage of 11 kv xlpe cable size 3x185/3x300 sq.mm. cable form store center mathura/agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends., carriage of line material i.e. conductor, g.i. wire tpmo stay rod, discinsulator, cross arm, angle channel and other required material from store center at 132 kv substation mathura to the site of work including loading and unloading of material at both ends., erection of single pole structure 8.5 mtrs on pcc pole by digging of pits fitting of all relevant accessories as per respo norms., erection of single pole structure 9/11 mtrs on st pole by digging of pits fitting of all relevant accessories as per respo norms., erection of double pole structure 8.5 mtrs on pcc pole by digging of pits fitting of all relevant accessories as per respo norms., erection of double pole structure 9/11 mtrs on st pole by digging of pits fitting of all relevant accessories as per respo norms., installation of stay set with grouting and nuzzling etc. as per respo drawing along with all routine material to be used for such works., earthing of poles by fixing earthing rods and binding with earth wire as per standard norms including cost of labour t&p and required material for such work., laying, sagging stringing and binding of acsr weasel conductor on the erected pcc pole/stp including jumpering as per respo manual., laying, sagging stringing and binding of acsr dog conductor on the erected pcc pole/stp including jumpering as per respo manual., laying, sagging stringing and binding of arial bunch conductor on the erected pcc pole/stp including jumpering as per respo manual., laying, sagging stringing and binding of lt pvc cable on the erected pcc pole/stp including jumpering as per respo manual., laying of 11 kv xlpe cable size 3x70/3x120 sq.mm. in the trench/g.i pipe/hdpe pipe and re-dressing of trench after laying of xlpe cable for proper completion of work as per direction of supervising engineer., laying of 11 kv xlpe cable size 3x185/3x300 sq.mm. in the trench/g.i pipe/hdpe pipe and re-dressing of trench after laying of xlpe cable for proper completion of work as per direction of supervising engineer., filing of cable box as suitable size as per direction of supervising engineer., filing of straight through as suitable size as per direction of supervising engineer., chopping of tree branches to clear the route properly., mounting of 16 kva transformer on the double pole/plinth struct
Tender For corrigendum : custom bid for services - pre-monsoon maintenance of lt and ht ohtl of gouri deep ocm, gsa.- 1 8.5.3 supplying and erecting porcelain shackle type lt medium insulator, 50x89mm dia. with g.l. (shackle) strips, nuts and bolts, complete 300 each, 2 8.5.17 supplying and erecting polymer pin type insulator with gi pin suitable for 11kv line, complete as per specification no. oh-ins/pn 300 each, 3 8.5.20 supplying and erecting polymer disc type insulator 45kn with necessary hardware suitable for 11kv line, complete as per specification no. oh-ins/di 200 each, 4 8.5.15 supplying and erecting distribution class, 11 kv thyrite type lightening arrester with nut bolts, on provided ms channel as per specification no. oh-ins/la 6 each.
Tender For corrigendum : supply of material and erection of equipments and structure for construction of 01 no. 132/33kv bay at 132kv sub-station harraiya under electricity transmission division-i, basti - supply, pale fencing, earthing 40 mm ms rod for main earthing, earthing 40 mm ms electrodes ( 3 meter longs), m.s. flat for earthing 75x10, m.s. flat for earthing 50x6, air conditioning system, two ton window ac with all accessories and stabilizer(not less than 5kva capacity) with installation, single tension fitting suitable for, acsr moose, acsr panther, single suspension fittings suitable for, acsr moose, acsr panther, pg clamp suitable for, moose/ moose, moose/panther, panther/panther, bus post clamp suitable for, panther, twin panther, moose, lightening fixture led luminaries type sl-di as per tech specifications, work, erection of main & auxiliary structure consisting of column. beam peak, mast etc and auxiliary structure of installation of cts, la etc. the job consists of shifting of all materials from store to site of erection and erection of structures as per drawing with the help of gi nut & bolts, flat & spring washer with matching the hole, cutting & matching of member if required, including cost of all men and t&p excluding gi structure nut & bolts to complete the work. gi structures, nut & bolts and washer will be provided by department free of cost., erection of 145 kv equipments, 145 kv bus/line and tandom isolator, 145 kv current transformer, 145 kv post insulator, 120 kv lightening arrestor, 145 kv ct junction box, 132 kv transformer (c&r) panel, 145 kv sf-6 circuit breaker, erection of 33 kv equipments, 33 kv vacuum circuit breaker, 33 kv isolator, 33 kv current transformer, 33 kv lightening arrestor, 33 kv ct junction box, stringing of three phase jack bus 132 kv with panther conductor. the work includes cutting & bending of conductor, fixing of single/double bolted type tension fitting/suspension. hoisting of discinsulators and shifting of material from store*site to erection site and all other associated work to complete the job satisfactorily as per instruction of engineer incharge., 132 kv jack bus for transformer, 132 kv making of u jumpers, equipments interconnection jumpering with main bus bar. job includes bending of conductor in proper shape tightening with the help of clamps and all other associated work to complete the job., transformer bay for 132 & 33 kv side, laying and termination of following size control cable in trench/cable trays from different control room c&r panels to switchyard equipments (132/33 kv cb, ct their junction boxes . transformer marshalling etc) in 132/33 kv switchyard as per cable schedule including carriage of cable drum from store and all other associated work., 2cx2.5mm2, 4cx2.5mm2, 6cx2.5mm2, 10cx2.5mm2, termination of control cable ( per termination), cutting strengthening bending and laying 700 mm/500 mm below inside ground and above ground of following size m.s. flat for earthing of main and auxiliary structure and equipments including welding with main earth mat and with objects to be earthed, excavation trenches and back filling painting and all other associated work as required to complete the work satisfactorily. m.s. flat will be providing by the contractor free of cost., 75x10 mm, 50x6 mm, making delta earthing of 120 & 33 kv la by fabrication of 03 nos 3 mtr m.s. round bar ( 36/40 mm dia) electrode it piercing inside the ground and connecting all 03 nos electrodes with 36/40 mm m.s. round laying around as per drawing painting the jointing with 75x10 mm m.s. round bar laying around as per drawing. painting the joints with black japan paint of good quality after proper cleaning of joints by wire brush ms round bar will be provided by dept, free of cost., dismantling of 250k.va 33/0.4k.v station t/f work includes opening of jampers/cable connection/cutting of earthing etc., laying of 300/400mmsq. 3.5core power cable from