Web Analytics Made Easy - StatCounter

Dismasting Tenders

Get complete information related to latest Dismasting Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dismasting Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dismasting Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45715657 Due date: 15 Jul, 202615 Jul, 2026 17.38 Lacs
Tender For tender for supply of erection and fabrication work b c c - juice/water scale ke weight channel bed mein se gale/kamzor channel ko kaatkar hatana. poorvanusar naya banakar lagana evam trial dena. , juice weighing scale ke filling tank ke rods ki kamzor/gali guides ko naya banakar lagana. , juice. maceration water evam final molasses ke weighing scale tank ke gale/kamzor bottom cone ko kaatkar purane anusar naya bottom cone lagana va poorn trial dena. , juice weighing system ke measured juice receiving tank ki gali/kamzor bottom evam side plates ko kaatkar hatana evam nirdeshanusar purani/nai plate lagakar leak.proof trial dena. , raw juice pump par lage catcher ko kaatkar hatana tatha naya catcher fabricate kar yathasthan lagakar samast connection poorv ki bhanti karna evam leak.proof trial dena. , pan. quad body evam vapour line juice heaters ki hydraulic testing ke liye inlet evam outlet ke vapour pipes mein cutting karke plate ke blind weld karna tatha hydraulic uparant blind kaatkar hatana evam vapour pipe ko punah andar va bahar se leak.proof weld karna. , semi kestner. vapour cell. quad body juice heater. vapour line juice heater ke condensate bottles tatha syrup receiving bottles ke cells ko kaatkar ceiling baffle plate ke kamzor hisse. bottom plate ke kamzor hisse athva cell ke kamzor hisse ko badalkar condensate bottles/syrup receiving bottles ki vanchhit marammat kar jal bharav parikshan dena. , juice heater mein lage ayatakaar juice entry box ko dismantle karna. gale/kamzor charon nipples badalna. double beat valves ki fitting hetu dono flanges lagana. box ki marammat kar box fit karna evam double beat valve fit karke leak.proof parikshan dena. , sabhi juice heaters ki gali hui sampoorn partition plate ko kaatkar bahar nikalna va nai 8/10 mm plate lagakar gili hui ring ko leak.proof welding karna tatha lagi hui tubes ko bachakar santoshjanak trial dena. , juice heaters mein dono taraf partition plate ki kamzor m.s. strip ko dismantle karna. kate face par grinding kar nai 25 mm x 5 mm ki m.s. strip banakar lagana evam rubber fit karna. , juice sulphiter ke recovery tower ke gale/kamzor bottom cone ko kaatkar 10/12 mm moti m.s. plate se sample anusar naya cone fabricate kar yathasthan fit kar leak.proof welding karna. , juice sulphiter ke base ke charon side ke gale/kamzor horizontal beams ki vanchhit strengthening hetu unke andar 12 mm moti plate lagakar majbooti pradan karna. , juice/syrup sulphiter ke kamzor bottom cones evam top cones ko dismantle kar sample anusar naya banakar fit karna. tatha andar va bahar se leak.proof welding kar santoshjanak jal bharav evam trial dena. , syrup sulphiter ke tower ki gali/kamzor baffle plates/jaliyon ko bahar nikalna. vanchhit marammat kar yathasthan fit kar leak.proof trial dena. , syrup pump se syrup sulphiter tak dono pumps ki delivery ki dono lines ko neeche utarkar garam karke. bhali bhanti safai karna. gali hui pipe line badalkar valve. bend. nipple ityadi lagakar punah lines ko fit karna evam leak.proof trial dena. , syrup/juice sulphiter ke upar lage recovery tower ko utarkar gali shell ko nirdeshanusar nai/purani plate se shell taiyar kar fit karna evam tower ko punah yathasthan lagakar leak.proof trial dena. , juice/syrup sulphiter/clarifier ke kamzor shell ke kamzor bhag ko kaatkar hatana. nirdeshanusar nai/purani 10/12 mm plate se banakar yathasthan lagakar andar va bahar se leak.proof welding kar trial dena. , sulphur bhatti (juice/syrup) ke gale/kamzor secondary gas cooler ko kaatkar hatana. 10/12 mm moti plate se purane ke anusar naya cooler fabricate kar yathasthan fit kar samast connection poorv ki bhanti kar leak.proof gas trial dena. , sulphur bhatti station par juice/syrup hetu sthapit sulphur bhattiyon ke gas coolers ke gale/kamzor cooling pipes ko kaatkar hatana. purane anusar naye pipes taiyar kar poorv ki bhanti fit kar leak.proof trial dena. , sulphur bhattiyon ke gale gas headers ko kaatkar hatana. purane anusar naye headers taiyar kar lagana. , sulphu

CTN :45715693 Due date: 15 Jul, 202615 Jul, 2026 19.48 Lacs
Tender For tender for supply of erection and fabrication work - pan/quad bodies ki kamzor shell ko kaatkar hatana. 10/12 mm moti plate se taiyar kar yathasthan lagana. andar aur bahar se double coat welding kar leak/proof water/vacuum trial dena. , quad evam pan par lage vapour/steam line mein lage 600/1000 mm dia ke right/angle type vapour valves ko dismantle kar valve ki leak/proof marammat karna evam testing uparant punah yathasthan fit karna. , pan/quad ke vapour pipe ke gale/kamzor vapour pipe bends ko naye fabricate karke badalna 600 mm se 1100 mm dia. , quad evam pan ke vapour pipes. vapour/exhaust steam lines ko majbooti pradan karne ke liye angle iron athva plate se t/rings banakar support dena. , vapour cell. semi/kestner. pan va quad bodies ki purani gali steam jackets ko hatakar nikalna. 10/12 mm plate se naya banakar lagana tatha leak/proof trial dena. , pan. quad. vapour shell adi ka fin type cyclone fit karna. naya 8/10 mm plate se banakar fit karna tatha welding kar santoshjanak trial dena. , quad/pans par sthapit vibhinn steam ke gale/kamzor/leaky valves ko kaatkar/kholkar hatana tatha valve ki vanchhit marammat uparant nirdeshanusar fit karna. , air cooled/dry seed/vacuum/twin vertical crystallizer ki drive ke kshatigrast/ghise hue worm wheels ki gland housings ke bush badalne ke liye worm wheel evam worm shaft housings ko dismantle kar alag karna. gland housings mein naye gun metal bush lag jane par housings ki fitting uparant uplabdh karaye gaye worm wheel evam worm housings ko poorv ki bhanti fit kar alignment karna. , vacuum crystallizer ke shell ke gale/kamzor bhagon ko kaatkar hatana. nai/purani plate se shell modkar yathasthan fit karna. andar aur bahar se leak/proof welding karna tatha bahar se vanchhit strengthening karna. , air/water cooled/vacuum/twin vertical crystallizer ke kshatigrast danton wale worm evam worm wheel ko dismantle kar hatana evam unke sthan par naye worm evam worm wheel fit karna. reduction gear evam motor fit karke alignment karna evam trial dena. , pans/crystallizers par lage vibhinn gutters mein se kamzor gutters ko kaatkar hatana. purani plate se banakar lagana. , air/water cooled crystallizers ki purani/kamzor/tooti hui shaft ko dismantle karna. nai shaft taiyar kar yathasthan lagana evam samast arms lagakar santoshjanak trial dena. , air/water cooled crystallizers ki shaft ke gale/kamzor bhag ko kaatkar hatana. m.s. plate se shaft taiyar kar naye pipe ki shaft yathasthan fit karna evam samast arms poorv ki bhanti lagakar santoshjanak trial dena. , crystallizers ki drive shaft ke dono taraf dheele hue/ghise gun metal bush bearings ko nikalna. naye bush fit kar trial dena. , air/water cooled crystallizer ki shaft par lagi kamzor arms ko kaatkar hatana aur m.s. plate/pipe se nai arms fabricate karke shaft par lagakar sucharu trial dena. , air/water cooled crystallizer ke leaky/kamzor gate valve ko repair karke leak/proof fitting karna. , spray hetu sthapit mf 35x35 spray pumps ke elliptical suction pipes mein se gale/kamzor section pipes ko dismantle kar hatana. 8/10 mm moti m.s. plate se sample anusar may strainer fabricate kar yathasthan fit kar leak/proof trial dena. , quad/pans ke condenser mein lage multi/jet spray boxes ki vanchhit marammat karna. , spray pond ke main header. branch header evam branch lines ke gale/kamzor bhagon ko kaatkar nirdeshanusar nai evam purani plate se taiyar kar yathasthan fit kar leak/proof trial dena. , common injection header ke kamzor bhag ko kaatkar hatana. naya fabricate kar yathasthan erection kar leak/proof trial dena. , injection. spray pump ki drive motor ke gale/kamzor resistance box taiyar karna. sabhi internals fit karna. connection kar santoshjanak trial dena. , vertical spray pump ke gale/kamzor base frame ko dismantle karna. poorv ke anusar naya bed fabricate kar level karke yathasthan lagana evam pump fit kar alignment kar dena. , pans ke gale/kamzor feed distribution headers ko kaatkar hatana tatha unke sthan par nirdeshanusar m.s. plate

Central Government And Public Sector

CTN :45723977 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For auction sale of depot miscellaneousellaneous scrap - lot of scrap wooden consisting of miscellaneous sorts and off sizes wooden furniture, material almirah, window, table, chair,packing wood, damaged plywood, wooden boxes with iron attachment and wooden pallets,wooden items with or without dismantle broken condition and with or without iron, cushion and slightly nf/f and other attachment.as available as in the lot. cutting or breaking allow only for loading pupose. (p.l. no-98410088). remarks:- if any non ferrous items found during delivery it should be removed from lot and purchaser should be handed over to the stock holder.

Central Government/Public Sector

CTN :45738510 Due date: 10 Jul, 202610 Jul, 2026 3.74 Lacs
Tender For supply of hi wall split ac 2.0 tr 5 star , hi wall split ac 1.5 tr 5 star , hi wall split ac 1.0 tr 5 star , stabiliser 5 kva for 2.0 tr ac , stabiliser 4 kva for 1.5 or 1 tr ac , insulated copper refrigerant piping set for 2.0 tr split ac , insulated copper refrigerant piping set for 1.5 and 1.0 tr split ac , wire or cable , pvc pipe , ms angle , installation testing and commissioning of ac , dismantle shifting reinstallation

State Government

CTN :45718975 Due date: 15 Jul, 202615 Jul, 2026 4.13 Lacs
Tender For नकारा घोषित उप स्वास्थ्य केंद्र भवनों का डिस्मेंटल - dismantle of sub health center buildings declared useless

CTN :45707244 Due date: 09 Jul, 202609 Jul, 2026 27.86 Lacs
Tender For providing, supply of 200mm temper proof air valve with isolating sluice valve, 300mm sluice valve and by back old dismantle/scrape/unusable material for jalundra-madhavgadh pipe line project.

Central Government/Public Sector

CTN :45469096 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For bid to ras supply of 5-star 1.5tr window type inv. room ac 35210001050153 , accessories 1.5tr window type room ac 35210009004724 , dismantle, erect/install, test&commission 352100011000003 , erect/install, test&commission 352100010500002

Central Government/Public Sector

CTN :45702821 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For auction sale of others - scrap condemn transformer with ferrous and non ferrous attachment qty-03 nos hett 5400 kva damaged and dismantle released from electric locomotive ferrous 19230 kg and copper 4629.00 kg aluminum 924 kg insulation 357 kgs total weight 25140 kgs sse lot no st/trs/cs/scrap/transformers 06/06. note 1: delivery can be given by actual weight 2. lot to be sold on as is where is basis is any other material except description is found while delivery which is strictly restricted and it cannot be delivered.3. the quantity shown against lot is approximate and there may be variation in weight as such variation of+/- 10% may be occurred due to average weight assessed. 4. cutting may allowed for easy loading and arrange by the firm/purchaser .5. it is strictly advised to the bidder to see the lot and loading point personally before bidding the lot in e -auction. no claim will be entertained after sale of the lot

CTN :45671096 Due date: 30 Jun, 202630 Jun, 2026 4.83 Lacs
Tender For repairing, raising up of manholes, road gullies and box channel alongwith p.f of missing road gully/ manholes cover and frames and also casting of dismantle portion of manhole and box channel of roof slab, disposal of malba etc from jn. no.38 (tribun

CTN :45679372 Due date: 02 Jul, 202602 Jul, 2026 20.16 Lacs
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tape changer in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)
 Loading, Please wait...

Connect us via What's Up