Web Analytics Made Easy - StatCounter

Displacement Transducer Tenders

Get complete information related to latest Displacement Transducer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Displacement Transducer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Displacement Transducer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45666399 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For supply of rectilinear displacement transducer with cylindrical case & accessories, resistance 2 k-ohm, max. vo

Central Government/Public Sector

CTN :45589289 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For load cell tension and compression range 50 kn , load cell tension and compression range 100 kn , displacement transducer (0 - 200 mm) , load cell tension and compression range 5000 n , load cell tension and compression 10000 n , load cell tension and compression range 20000 n

CTN :45225555 Due date: 12 Jun, 202612 Jun, 2026 17.30 Lacs
Tender For corrigendum : supply of balluff linear displacement transducer part no. type btl5-s172-m0860-k-sr32 or equivalent subjected , balluff linear displacement transducer part no. btl7 s572 m1600 p s32 or equivalent subjected to fit , balluff make linear displacement transducer part no. . btl7 - s572 - m3750 - p- s32 or equivalent mak , balluff make linear displacement transducer part no. . btl7 s572-m1700-p-s32. or equivalent make sub- , balluff make linear displacement transduc- er, with part no. btl7-s572-m4000-p-s32 or equivalent make

Central Government And Public Sector

CTN :45370627 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For supply of linear displacement transducer

CTN :45346428 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign

CTN :45346446 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to

CTN :45221075 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For supply,demonstration & training of capacitive based non-contact displacement transducer with controller and accessories

CTN :45085574 Due date: 15 May, 202615 May, 2026 NA
Tender For providing of design installation and maintenance of educational lab/centre - vocational lab; supply and installation of hardware - connecting screwdriver, neon tester, screw driver set, insulated combination pliers, insulated side cutting pliers, long nose pliers, soldering iron, electrician knife, tweezers, digital multi meter, soldering iron changeable bits, de-soldering pump, steel rule, steel measuring tape, tools maker vice, crimping tool (pliers), scriber straight, allen key set, double ended spanner, magnifying lenses, hacksaw frame adjustable, cold chisel, scissors, handsaw, drill machine (electrical), first aid kit, fire extinguisher, bench vice, dual dc regulated power supply, lcr meter (digital), cro dual trace (component testing facilities), battery charger, analog multi meter, function generator (triangular, square and sine wave), electronic work bench, comprising of dc power supply, dmm, amm, cro, function generator, dimmer-stat, component, tray, soldering station., dimmer state, analog component trainer, op amp trainer, digital ic trainer, digital ic tester

CTN :45072362 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For supply of electronic equipments d d - led tv trainer kit , lcd tv trainer kit , 5 g volte mobile trainer , gunn based microwave testbench , photodiode and ldr trainer , digital lcr with q meter , digital multimeter , cro , function generator , power supply

CTN :44856628 Due date: 27 Apr, 202627 Apr, 2026 NA
Tender For corrigendum : supply of balluf make linear displacement transducer with part no. btl7-s572-m3000-p-s32 , linear displacement transducer, balluf make type btl5-s172-m1100-k- sr32. , linear displacement transducer order code - btl7- s572-m1250-p-s32 balluff make germany , linear displacement transducer order code btl7- s572-m1000-p-s32, balluff make germany
 Loading, Please wait...

Connect us via What's Up