Tender For corrigendum : supply of 11744 - disposable - blood lancet (for finger prick) round [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of sch viii (supply of needle & syringes) - sch viii (supply of needle & syringes), disposable needle sterile length 1/2" guage 25, suture needle, half circle triangular nos. 2 to 20 (cutting), insulated needle for use with peripheral nerve stimulator 22g x 2" x 50 mm., insulated needle for use with peripheral nerve stimulator 22g x 35 mm., insulated needle for use with peripheral nerve stimulator 24g x 1"x 25 mm., echogent needles for usg guided peripheral nerve blocks 20g / 21g x 100 mm., echogent needles for usg guided peripheral nerve blocks 22g x 50 mm., epidural needles 16 & 18 guage 7.5cm to 11cm (disposable), epidural needles (long length) 18g (more than 100 mm. length), sterile disposablelancet size 28-32 (plastic lancet needle type), sterile disposable hypodermic plastic syringe 20cc, cn. with leur lock, hypodermic syringes,disposable sterile, sterile pack,with/without leur lock, hub 1ml syringe with marking at 0.1 ml, asepto syringe 100 ml of heavy plastic barrel and rubber bulb with marking., bag arm rubber with cover for b.p. apparatus, adult size velcro.rubber bag size 13 x 23 cms., keratome, size 2.8 mm, type-regular(ophthalmic), angle-45 degrees, bevel type- bevel up (pointed)blade-stainless steel/carbon steel,handle- polycarbonate, use- disposable single use, mvr, gauge 23g type-regular(ophthalmic), blade-stainless steel handle- polycarbonate, use- single disposable use, triple lumen catheter 7.5fr with 14g distal lumen, length-15cm. kit contain 1 teflon-coated j nitinol guidewire particularly kink-resistant with guide-advancer. 1 dilator, 10cm long, 3 injection caps, 3 clamps,1 supplementary fixation wing,1 scalpel, 1 syringe 5 ml, 1 adaptor for pressure transducer, 1 puncture needle 18g, 70mm long with a pre-connected valve to aviod air embolism and blood loss, 18g short iv cannula, double lumen subclavian/ jugular catheter kit (adult) ptfe (teflon) cannula curved od 2.7/d 11.5fr-12fr/chx5.3in. (3.8 mm x 13.5 cm) 6 side holes silicon tube s clamping extension, clamp luer lock "y" connector with protective caps size 12.5, 15 with guide wire introducer needle, dialator , 3fr double lumen cvc catheter with 60mm double-lumen polyurethane central venous catheter inserted by seldinger technique, radio opaque material for catheter, the user should be able to choose from 2 type of introducer, i.e.needle 23g or i.v. cannula 22g, latex free, the central venous catheter set should contain: 1 double-lumen polyurethane 3fr catheter, 1 short i.v. cannula 22g, 1 introducer needle 23g, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection caps, 1 scalpel, 1.5 ml syringe, peripherally placed radiopaque central single lumen catheter. guage 14/16 (100%) (needles size/catheter size) length - 55cm - 70cm, peripherally placed radiopaque central single lumen catheter. guage 18/20 (100%) (needles size/catheter size) length 30cm - 45cm, fully radiopaque pur catheter 16g for femoral artery centimeter marking from 5-15cm, winged hub for skin fixation, supple distal tip. kit should contain 1 pur catheter with xro lines,1 puncture needle, 1 j guidewire with wishbone-type guidewire advancer, 1 dilator, radial/femoral arterial pe catheter with antikinking collar & fixation wings,straight guide wire, introducer needle.catherter size g- 18, length 10cm, radial/femoral arterial pe catheter 20g, 8cm puncture needle is fitted with a visualization chamber allowing to confirm that the vessel punctured is an artery (pulsatile movement of the blood). the needle is also fitted with a silicone bloodless system valve to avoid loss of blood during vessel puncture and a funnel hub to facilitate the insertion of the guidewire, peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leur connector at proximal en
Tender For corrigendum : supply of ortho d d - periprosthetic fracture , sterile endobutton , biocomposite interference screws , biocomposite biphasic beta tricalcium sulphate , variable loop endobutton , acl pcl reconstruction set , ultrahigh strength , multistrand long chain ultra high molecular , endobutton titanium , all inside meniscal repair device in sterile pack , endobutton titanium metal , biocomposite peek , disposable suture passer , sterile disposable cannula for shoulder arthroscopy , sterile disosable clear cannula , titanium anchor suture , fibre wire , sterile titanium double prong ligament , osteochondral graft harvest and transfer set , sterile underwater electrosurgical device , sterile tur set , sterile camera cover , titanium suture disc , ethibond , mersilene , sterile underwater electrosurgical device , punching self punching knotless anchor suture , biocompound peek anchor , screw post for arthroscopy , knotless peek anchor , low viscocity pmma bone cement , antibiotic gentamycin impregnated pmma bone cement , austin moore prosthesis , cemented total hip system cemented tapered stem having various sizes , non cemented total hip system metal , non cemented total hip system , modular bipolar hemiarthroplasty system , basic high flex total knee replacement system , high flex total knee replacement system , shoulder hemireplacement prosthesis modular , total shoulder arthroplasty set , radial head prosthesis , uncemented bipolar hip system all sizes , titanium forearm plate , titanium narrow locking plate , non cemented long stem bipolar hemi arthroplasty with modular bipolar , cemented long stem bipolar hemi arthroplasty , dual mobility hip system with titanium porous multiholed , revision total high flex knee replacement system , narrow stem non cemented total hip replacement system , narrow stem cemented total hip replacement system , revision non cemented large acetabular component , revision hip acetabular component , revision non cemented long femoral stem , revision non cemented long modular femur stem titanium , antibiotic spacer articulating the knee , trochanteric reattachment devices , disposable o drape , disposable u drape , normal saline bottles , bone substitutes , skin stapler with extractor disposable , surgical scrub brush , antimicrobial incision drape sheet , disposablesurgicalgown wrap around types , sterile disposable o drape , level 3 , hot pack , long cautery pencil , disposable skin stapler , c arm drapes , orthopaedics gloves latex , orthopaedics gloves latex free , lodophor impregnated adhesive film pelvic brim plate, pelvic brim plate, anterior column plate , anterior column plate , pelvic curved recon plate, suprapectineal plate, infrapectineal plate, pelvic j recon plate, pelvic j recon plate, proximal femoral anatomical locking plate suitable, proximal femoral anatomical locking plate suitable, dhs set consisting of one richard screw , paediatric dhs set consisting of one richard screw, locking proximal femoral hook plate suitable, locking proximal femoral hook plate suitable for fixation , proximal femoral nail, proximal femoral nail, proximal femoral nail, proximal femoral nail, proximal femoral nail, proximal femoral nail, trochanteric femoral nail with single screw/ blade, reconstruction nail for femur with provision, reconstruction nail for femur with provision of trochanteric , interlocking nails for femur , interlocking nails for femur , distal femoral lcp, distal femoral lcp, distal femur medial anatomical locking plate, distal femur medial anatomical locking plate, distal femoral nail with two proximal and //bid details 2 / 116