Tender For supply of dissolvedacetylenegas confirming to is:308/1988 with amendment no. 1 reaffirmed 2 005 and as per general technical requirement. [ warranty period: 30 months after the date of delive ry ]
Tender For bid to ras providing of custom bid for services - maintenance of instruments installed at blast furnance, compressed air station, gas mixing and boosting station,weigh bridges,central instrumentation laboratory, ldcp and auxiliaries along with gas analyzer for a period of ..
Tender For annual rate contract for the supply of gases - annual rate contract for the supply gases, refilling of zero air gas, uhp- 99.999%,7 cubic meter per cylinder, refilling of hydrogen gas, uhp-99.999%,7 cubic meter per cylinder, refilling of argon gas, uhp- 99.999%,7 cubic meter per cylinder, refilling of nitrogen gas, uhp- 99.999%,7 cubic meter per cylinder, refilling of helium gas, 99.999%,7 cubic meter per cylinder, refilling of oxygen gas, 99.9%,7 cubic meter per cylinder, refilling of oxygen gas, uhp-99.999%,7 cubic meter per cylinder, refilling of carbon-di-oxide (co2) gas, uhp-99.999%, 30kg per cylinder, refilling of dissolvedacetylenegas, uhp- 99.999%, capacity 6.0 meter, refilling of dissolvedacetylenegas, 99.9%, capacity 6.0 meter, refilling of nitrous oxide gas 99.99%, capacity 17.0 cubic meter per cylinder, bronze service plan ; hsn code:90278990
Tender For repair and overhauling service - repair of set, maintenance omts; repair of set, maintenance omts; yes; buyer premises-work for calibration of overpressurizer maintenance test set (omts)- calibration of overpressurizer maintenance test set (omts) is to be carried out from csir-national physical laboratory (npl), new delhi or any other agencies, who has iso certification., the calibration of the omts must be carried out with nitrogen (n2) gas only below 250 bar [(0-40) bar manometer] and with a specific soft oil above 250 bar ((0-600) bar & (0-1000) bar manometers]., a specific process for degreasing after calibration of the manometers is necessary as well as multiple cleaning and rinsing with specific products required due to complex form of the "bourdon" tube of manometers, a curved shape with an oval section, the process for degreasing is very sensitive process., lrp price included the storage, transportation (to and fro), calibration of omts. omts is to be collected from 24 mmpu and after calibration same needs to be handed over to 24 mmpu along with calibration certificate and procedure. periodicity of calibration should be minimum 36 months or more., omts should be in serviceable condition (except tolerance value), when it is handed over to 24 mmpu after calibration., list of items should be handed over in fully serviceable condition post calibration as appended below:- overpressurizer maintenance test set (omts) container, belt tension test tool, pressure gauge key, 25 mm flat wrench, two hoses, reference marks (a) and (b), for connection to the single-phase overpressurizer, document folder (log card) female connector, male connector ruler, instructional manual, omts container cover, 0-40 bar manometer, 0-600 bar manometer, 0-1000 bar manometer,