Get complete information related to latest Distance Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Distance Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Distance Meter Tenders.
Tender For corrigendum : supply of spares along with service support of dcs and magnetic flowmeter of abb make on door delivery basis at hbl plant sugauli, east champaran, bihar - 845456 - supply of spares along with service support of dcs magnetic flowmeter at sugauli as per details below and attached tender document:, a0810v2 analog output 8 channelpart code: - 3bse038415r1 make abb, d0840 digital output 24v 16 channelpart code: -3bse020838r1 make abb, a1845 analog input s/r hart 8 channelpart code: -: 3bse023675r1 make abb, tu846 mtu for ci840 part code: - 3bse022460r1 make abb, tu847 mtu for ci840 part code: - 3bse022462r make abb, backplane type - 4product code: - 3kxf002058u0100 for magnetic flow meter model no fm300, make abb, display cartridge of 230volt ac (hart) product code: d674a906u01 for magnetic flow meter model no. fm300, make abb, repairing, servicing & troubleshooting of abb dcs systems and magnetic flow meters at hbl sugauli plant as per below scope:the scope of work for the deployed dcs engineer shall include, but not be limited to, the following services:1. diagnose and resolve hardware and software issues in abb dcs & magnetic flowmeter systems.2. carryout preventive and corrective maintenance of the dcs components & magnetic flow meters to ensure system reliability and uptime.3. replace or repair faulty i/o modules, power supplies, cpus, and communication interfaces.4. modify or develop control logic, function blocks, and graphical interfaces in line with process or operational changes.5. fine-tune pid loops and optimize control strategies based on real time process requirements.6. analyse system performance and suggest improvements.7. implement energy-saving or process optimization initiatives.8. training of technicians and engineers on-site.
Tender For corrigendum : supply of different single point and multi point cutting tools. , petrol engine 4 stroke , petrol engine 2 stroke , diesel engine 4 stroke , diesel engine 2 stroke , different types of boilers , thermometer and pressure gauges of different types , boiler mounting and accessories , plug- gauge , limit -gauge , steel ring gauges , different types of cams followers and cam follower arrangements , various belt drives, chain and sprocket, various gear drives. , friction apparatus for motion along horizontal and inclined plane , beam reaction apparatus , total station , gps instruments , electronic distancemeter , smart board
Tender For providing of calibration services - calibrator rtd for 4 nos; as per sow; as per sow; as per sow,calibration services - thermal imager make : fluke model -fluke for 2 nos; as per sow; as per sow; as per sow,calibration services - scope meter make fluke model no 19xc 2x5c accuracy : 0 point 8 for 2 nos; as per sow; as per sow; as per sow,calibration services - power bird meter make/model: bird/5000xt for 4 nos; as per sow; as per sow; as per sow,calibration services - lcr-q meter make : aplab 230volt ac 50hz for 2 nos; as per sow; as per sow; as per sow,calibration services - multifunction calibrator make : yokogawa/fluke for 4 nos; as per sow; as per sow; as per sow,calibration services - documenting process calibrators make : fluke 754 for 4 nos; as per sow; as per sow; as per sow,calibration services - optical tachometer display: 5 digits range: 2 point 5 to 999 rpm non contact type for 6 nos; as per sow; as per sow; as per sow,calibration services - portable pressure calibrator make/model: nagman range : -1 t
Tender For corrigendum : supply of c18b250038 8118140174 mass flow meter (coriolis type) process connection: 1" x 300# material: ss316 , 8118370368 mass flowmeter, coriolis , 8118380233 mass flowmeter , 8118375403 spare flow transmitter
Tender For supply of supply of consumables /implants /devices/accessories, on consignment basis for ctvs - ventilator, invasive pressure monitoring, iv drip sets, anticoagulation monitoring and airway consumables, bain circuit adultbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., bain circuit pediatricbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., corrugated tube connectorshould allow connection between all breathing circuits and the et tube connector.thecorrugatedtubeshouldbeexpandable.shouldallowmovementofbreathingcircuitatpatientend.should be made of medical grade pvc.should be compatible with ett and tracheostomy tube., micro aggregate blood filter for red cell transfusionfilter media should be 40 micron rated polyester screen media with uniform pore sizeshould have total filter surface area of 170 sq.cmshould have average capacity of filtering 10 units of blood., packed red cell & whole blood leucocyte reduction filters.bedside filtration of one & two unit of packed red blood cells or whole bloodshould have universal spike with microbiological recovery ventshould be with attached straight administration set/automatic self leveling drip chamberperformance should consistently average less than 2x105 residual leukocytes per unitred cell recovery should average greater than 90%.filter housing hold up volume should be 25ml for one unit filter and 35ml for two unit filterit should be single use, forced warming blanketshould be disposable and two layered; should consist of non woven propylene fabric for body warming. should be usable with forced air warming units. material should be latex free and should meet flammability standard 16 cpr 1610 for safety. the manufacturer must have all the below listed types of blankets and should quote the prices separately for separate blankets full body adult underbody adult with arm and head openings pediatric full body pediatric underbody blanket. should be compatible withcommon machines. should be ce certified, cuff inflator and pressure gauge itisusedtoinflate& preciselymonitorthecuffpressureofet tube, tracheostomy tube and lma cuff. reducetheriskofpressurenecrosisandmucosal ischemia theriskofaspirationcanbeavoidedeliminatestheuseofsyringestoinflate&deflatethecuffs. should have release valve to adjust the pressure. gaugecalibratedincmh2owiththedetachablelongconnecting tube. shouldhaveinflationbulbfortheinflationofthecuffshouldhavethehookatthebackoffitsintostandardrail.should have widely spaced scale markings with colour coded pressure ranges.ergonomiconehadoperation, intubation pillow reusable intubation pillow for head elevated laryngoscopy position (help) for airway management of obese &l arge framed patients. shouldbemadeupofdensefoam. shouldbesuppliedwithheadcradle shouldbevinylcovered shouldbecemarked, negative insipratory force meter should be disposable, compact, light weight & amp;single patient use negative inspiratory force meter to check the negative inspiratory force of the ventilated patients with the facility of memory indicator point ertore cord reset highest force achieved by the patient individually packed ready for use. shouldbe ,ce marked, capnography co2 sampling mask shouldhavetheprovisionforbreathtobreathmonitoringforboth nose & mouth should have the facility to deliver oxygen; allow sampling of exhaled carbon dio