Get complete information related to latest Distribution Boards Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Distribution Boards Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Distribution Boards Tenders.
Tender For corrigendum : tender for providing installation testing and comissioning of various capacity split acs to avoid overheating of electrical distributionboards & sensitive electrical components at 33/11kv s/stn jabli feeding to aiims hospital and nearby areas & 33/11kv s/stn beri in electrical section jabli & beri respectively under electrical sub- division hpsebl no.iii & no.-i, hpsebl, bilaspur. (ts no. 26/2019-20 wbs no. d-19-1339)
Tender For corrigendum : repair/maintenance of main distributionboards, service connections, submain wiring, building security lights, building earthing and connected works under ge (east) mathura
Tender For providing of custom bid for services - maintenance and repair of ht 11 3 3kv power distributionboards and maintenance of ht transformers upto 5 mva of battery coke & coal handling plant and by product plant of cob 10 complex
Tender For supply, erection, testing and commissioning of ct meter of standard make with cubical meter box as per hvpnl specifications including 3 phase electrical meter 100/5 of standard make approved by hvpnl including ct/pt of suitable rating complete in all respect as per directions of engineer-in-charge ,mccb ,distributionboards, mcb`s, rccb`s, change over etc. 8.1. supply, installation, testing and commissioning four pole on load manual change over switch in ss enclosure of following ratings 63 amp 415 volts
Tender For rewiring and replacement of old switches/socket etc with modular and distributionboards, table lamps in otm accn of grc kamptee under ge kamptee.
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For corrigendum : procurement of spares and consumables required for the lv switchgear equipment panel boards such as unit auxiliary boards, station auxiliary boards, reserve boards, lighting distributionboards, power distributionboards, chillers, lv motors terminals and its starter panel boards at power house of ljhep, atmakur
Tender For corrigendum : comprehensive maint of internal sub main wiring, mcb distributionboards and meter control panels at zone - i area under ge (a) jaisalmer
Tender For pdg. street lights alongwith other allied items in parking area of old mini sectt., distt. kurukshetra.- el035. ms clamps, mccb ,distributionboards, mcb`s, rccb`s, change over , mccb ,distributionboards, mcb`s, rccb`s, change over, lt cables, street ligh, ]street light, watt led street light