Get complete information related to latest Distribution Main Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Distribution Main Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Distribution Main Tenders.
Tender For laying of 200mm di distributionmain pipe line from kimbhiria esr to ggp labour stand in ward no.19, bmc, under watco section ggp colony, bbsr
Tender For laying of 150mm dia di distributionmain pipe line from sameigadia old pump house to mancheswar village in ward no.5, bmc, under watco section ggp colony, bbsr
Tender For deposit laying 63mm pvc pipe as csme along service road of nh for providing water connection for holiday inn at kochi coprpration division no 33 old pipe line work pipeline work
Tender For mla - sdf - cwss to nallepilly,perumatty,pattanchery and elapully grama panchayaths - ozhivupara - supplying and laying distributionmain at ozhivupara in nallepilly grama panchayath - general civil work
Tender For special repairs to the electrical installation to the existing head office old building with light fittings, fan fittings, main power distributionmain panel units, sub panel unit and ltct service connection with allied electrical works in ground flo
Tender For regular operation and maintenance of water supply scheme with material at industrial area, residential colony and commercial complex jhunjhunu phase-i and ii - item rate, regular operation of tube wells installed with pumping machineries with round the clock monitoring, including complete repair and maintenance of pump set with cost of material and labour required for repairing/rewinding, lowering and un-lowering etc.the scope of work also includes repair and maintenance of panel board, main switches, kit-kates, electric connections, service cableand submersible cables inclusive of cost of material and labour required for uninterrupted functioning of tube wells.it is also inclusive of complete repair and maintenance of pipes connected with pump and motor, its replacement, if required, regular upkeeping of log book etc. and other works as mentioned in tender document / scope of work complete in all respect and as directed by engineer in-charge., regular operation and maintenance of pump houses located at wss complex/complexes.the work includes operation of distribution line main valves for daily supply of water of the industrial area at supply times specified by corporation. regular operation of pump house installed with existing centrifugal / monoblock pump / motors, with round the clock monitoring, including complete repair and maintenance of pump sets, connecting suction/delivery pipes jointing material, panel, main switches, kit-kates, electric connections, service cable including cost of material and labour required for repairing / rewinding, removal and replacement etc. for uninterrupted functioning of electric panels and pump sets with regular up-keepment of log books, repair of leakages in pump glans and ms/ci/ac pipeline system inside of wss campus complete, regular chemical dosing in cwr maintaining general cleanliness at pump house and wss campus complete in all respect as directed by engineer in-charge., repair & maintenance of existing distribution / rising main pipe line system consisting of ac pressure pipeline /pvc/upvc/hdpe/ci/ di lines for maintaining smooth water supply in area covered under the scope of work.the scope of work includes timely repairing of leakage in all existing distribution / rising main pipeline of all sizes by digging out suitable size of pit in soft & loose soil / hard soil including cutting of bituminous / cement concrete / wbm / wmm surface at any site of work at no extra cost.it is also inclusive of cutting of pipe ends, fixing of pipe pieces with jointing material to make repair leak proof and refilling the pit / trench by excavated soil by ramming it at all sides of pipes & upto ground level. contractor will do dewatering at his own level by making necessary arrangements, if required. contractor will usetheir own t&p and jointing materials, however the pipe line and sluice valves (if required) etc. shall be provided by the corporation but the contractor shall have to deposit the damaged material in riico store. but no additional payment shall be made on account of any material or transportation charges.
Tender For supply of 6mm copper 3 phase high load power distribution , main control panel with auto cut control system , industrial grade caustic soda powder , welding electrode holder 1000amp heavy duty jaw holding plier electrode clamp , rebar metal cutting wheel professional expert , lift front welding googles polycarbonate ansi z87 1 certified , lift front welding googles black polycarbonate ansi z87 1 certified , measuring tape 15 feet acrylonitrile butadience styrene with abs case , heavy duty premium welding cable shield arc copper three phase
Tender For tender for supply of fixing self regulating heat tape cable insulation and accessories in ppr pipe - providing and fixing self regulating heat tape resistance heating cable suitable to protect freezing of water in pipelines having rated output of 35 w per meter at 220 v ac supply the heating cable shall have capabibility to automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable should be suitable for continuous operation in outdoor in adverse climatic conditions flexible for installation around pipelines joints and valves and compatible with temperature controller systems , providing m20 3 pin connector suitable for making secure electrical joints between self regulating heat cable terminals designed for reliable power and signal continuity the connector should be operable for operation at rated 220 v ac supply and compatible with heating cables of specified capacity must l ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be made up from high-quality weather resistant materials suitable for continuous outdoor operation under adverse environmental conditions it should be ease in installation with a compact and durable design for use in pipeline joints terminations and interconnections the connector should be compatible with temperature control systems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress , providing temperature differential controller with auto and manual operation housed in a robust ip65 rated enclosure suitable for controlling heat tracing systems to prevent freezing of water in pipelines and utilities the controller should be capable to automatically switch the heat tape on off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller should have in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions , providing pt100 temperature sensors with 10 metre cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors should be made up of platinum resistance type pt100 ensuring high precision stability and reliability over a wide temperature range the wire with sensor should have high quality insulation suitable for reliable signal transmission and compatible with temperature controllers and monitoring systems the cable shall be durable flexible and suitable for installation in outdoor under extreame weather conditions in high altitude area , providing 3 core 1.5 sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications rated for voltage grade up to 1100 volts the cable shall confirm to requirements of is 694 2010 the conductors shall be made of high-conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high-quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it should be suitable for continuous operation in indoor and outdoor adverse environments offering reliable performance electrical safety and long service life
Tender For providing laying 300mm dia distributionmain pipe line from milk scheme oht to nirbhay nagar jabalpur, neta ji subhash chandra bose ward zone 7.
Tender For corrigendum : laying, erection, commissioning and painting of service water pipeline for service water system - laying, erection, commissioning & painting of service water pipeline (900 meter of 250 nb) for service water system of 2×600 mw units at rgtpp, khedar, hisar.