Tender For corrigendum : repair of apf and roads in purchase center khane ki dhab apf with db paving and roads with premix carpet market committee malout and district sri muktsar sahib work code mks 26049
Tender For preparation of detailed project reports for package no. 1 improvements and resurfacing to road from b. gollarahatti road to db. halli road from km 0.00 to 2.30, d. upparahalli to mdr chornur road from km 0.00 to 1.26, approach road to d. upparahalli from km 0.00 to 0.70, jigenahalli village to tippanamaradi-hirehal road from km 0.00 to 2.83, devigiri to mdr road from km 0.00 to 6.01, swamihalli to camp annual repair road from km 0.00 to 1.30, jigenahalli village road to bommagatta village from km 0.00 to 2.70 and hiral to bandri-chornur road from km 0.90 to 3.50 in sandur taluk, ballari district.
Tender For supply of electrical materials for the repair and maintenance of street light as per the boq - details, t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder (porcelain), led driver 50w bis certified, led mcpcb plate 60w, led mcpcb plate 50w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolytic corrosion,excellent water resistance,suitable for primary ins
Tender For 1. proposed gym building for laman shikshan prasarak sanstha laman tanda (d.b.) sanchalit, special repair. siddheshwar highschool, siddhanath, in special repair no. 8, at siddhanath, tal. jat, dist. sangli.estimated cost: 1197584.00
Tender For corrigendum : repair/ rplmt/ maint of unsv lt poles, street light fittings, timers, junction boxes, internal wiring, db, fitting and fixtures at ins baaz, 172 inf bn ta,cgdhq-10 and 3udet campbell bay under ge campbell bay
Tender For corrigendum : annual maintenance of repair work resoling of interlocking , drain type -1and 2, db paving, culvets and others miscellaneous work in np nihal singh wala.
Tender For corrigendum : db college thalayolaparambu - vaikom group-cleaning premises before monsoon and some urgent repair works in connection with the college re opening for the academic year 2026-2027