Get complete information related to latest Divan Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Divan Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Divan Tenders.
Tender For supply of supply installation testing and commissioning of silent diesel engine driven generating set water cooled 415 volt 3 phase wire engine and alternator capacity 500 kva all work as per atc , supply laying testing xlpe insulated screened pvc bedded galvanized steel strip wire armoured elect power cable heavy duty 1100v stranded aluminium conductor size 300sqmm 3 point 5 core , excavation in trenches not exc 1 point 5m wide or not exc 1 point 5m depth for laying cable or getting out in any type of soil note depth for excavation is 0 point 6 mtr and width is 0 point 45 mtr , removing of excavated surplus soil not exc 50 m and deposited where directed at a level not exc 1 point 5 m above the starting point , returning filling in including spreading leveling watering and well ramming in layer not exc 25 cm thick , material and labour for clean dry tibba sand in trenches or ducts for cushioning to cable complete all as specified punned thickness shall be measured and paid , supply and laying stone patti 40 to 50 mm thick 25 to 30 cm wide abutting each other for cable protection complete all as specified , s and f in repairs galvanized steel tube light grade with fittings for protection of cable of 100 mm sizes complete all as directed by engineer in charge , m and l earthing complete as per electrical plate no 3 of mes ssr part i with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly vertically in ground all work as per atc , supply install testing commissioning indoor type cubicle panel board suitable for 415v 3 phase 4 wire 50hz ac supply system and design verified as per is or iec 61439 1 or 2 all work as per atc , m and l incl t and p for shifting of dg set capacity 100 to 500 kva within a distance of 3 km range or age em store yard all as directed by engr in charge , pvc water tank 750 ltrs 4 layer isi marked , allen and key set ki10v isi marked , tool kit bag nylon water proof isi marked
Tender For corrigendum : supply of service 11 kv ht panel , sf new mineral oil for panel etc , filteration of mineral oil , servicing of existing mv panel , check and rectification of em interlock , calibration relay etc , sf silicagel , sf 32a hrc fuselink , sf 63a hrc fuselink , sf 125a hrc fuselink , sf 250a hrc fuselink , sf led indication lampa 220v ac , sf 0 to 400a ac ammeter digital , sf 0 to 500a ac voltmeter digital , sf 0 to 30 a dc ammeter digital , sf slelector switch vlotage or current , sf operationg handles for sfu cubicle for extg panel , carryout servicing of 500kva ea set as per specification b chck , repair and service of radiator for 500kva ea set , attending air circuit breaker 800a gec make as reqd , servicing of air circuit breaker 800a gec make as reqd , sf 12v 180ah low mtce battery for ea set , sitc 5 kvar app capacitor , sitc 10 kvar app capacitor , sitc 15 kvar app capacitor , sf 6 stage auto power factor corrector reelay in extg panel , sf 400a mccb with handle on off lamp in sheet steel enclosure
Tender For corrigendum : supply of supply of hot dip galvanized octagonal street light pole of 7 mtrs length , supply of outdoor type 100w led type flood light luminaire , supply of outdoor type 90w led streetlight luminaire , design, fabrication, supply, installation, testing and commissioning of cubicle type, outdoor type feeder pillar panel , sitc of lt feeder pillar panel , supply power cable of 3. 5 x 50 sq. mm sqmm. , supply of xlpe insulated and pvc sheathed armoured aluminium conductor ug power cable of 4 x 16 sqmm. , supply of xlpe insulated and pvc sheathed armoured aluminium conductor ug power cable of 3. 5 x 300 sqmm. , supply of 50 mm od hdpe pipe of pe 80 pn 6 isi marked , supply of 63 mm od hdpe pipe of pe 80 pn 6 , supply of 110 mm od hdpe pipe of pe 80 pn 6 , supply of underground warning or caution tape size 6 x 250 mtr , supplying and making end termination 3. 5 x 50 sq. mm , supplying and making end termination 4 x 16 sq. mm , supplying and making end termination 3. 5 x 300 sq. mm , excavation for cable trenches in soft soil , laying of upto 63 mm dia size dwc or hdpe pipe , laying of 110 mm dia size dwc or hdpe pipe , laying of cable up to 35 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying of cable above 35 sq. mm and upto 95 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying of cable above 185 sq. mm and upto 400 sq. mm in the existing rccor hume or duct or metal or dwc or hdpe pipe as required. , laying and fixing of cable above 185 sq. mm and upto 400 sq. mm on wall surface , supplying and making of straight through joint with heat shrinkable kit 3. 5 x 300 sq. mm , dismantling bituminous road by manually or mechanical , supply and fixing of single arm bracket having arm length of 1. 2 mtr , supply and fixing of double arm bracket having arm length of 1. 2 mtr , supply of dp mcb, 6 a, c curve , supplying 3 core 1. 5 sqmm of frls pvc round sheathed copper conductor industrial cable , erection of metallic pole upto 7 mtr length including rcc foundation , installation, testing, and commissioning of 90w led type street light fixture , installation, testing, and commissioning of 100w led type flood light fixture , earthing with g. i. earth pipe 4. 5 meter long, 40 mm dia including accessories , providing and fixing 6 swg dia g. i. wire , providing and fixing 25 mm x 5 mm g. i. strip in 40 mm dia g. i. pipe , providing and laying in position cement concrete , dismantling of existing street light poles up to 9 meters , supply and erection of extra supporting ms structure with l channel , laying of caution tape over the cable trench
Tender For corrigendum : supply of supply of seal control cubicle spares for miv of francis turbine of njhps jhakri d d - valve service seal for miv seal control unit as per detailed ts enclosed , valve maintenance seal for miv seal control unit as per detailed ts enclosed , filter element 70 micron for miv seal control unit as per detailed ts enclosed , filter element 25 micron for miv seal control unit as per detailed ts enclosed , pressure gauge ss body glycerin filled 6 inch dial 0-100bar as per detailed ts enclosed , male stud connector g 1 by 4 inch bsp x 8 od for miv panel connection as per detailed ts enclosed , straight coupling ss304 for 12 od tube ferrule type pn250 as per detailed ts enclosed , equal tee ss304 for 25 od tube ferrule type pn250 as per detailed ts enclosed , straight coupling ss304 for 25od tube ferrule type pn250 as per detailed ts enclosed , equal elbow ss304 for 25 od tube ferrule type pn250 as per detailed ts enclosed , male stud connector ss304, g1 inch x 25 od tube ferrule type pn250 as per detailed ts enclosed , straight coupling ss304 for 08 od tube ferrule type pn250 as per detailed ts enclosed , tube connector for tubing ss304 for 08 od tube ferrule type pn250 as per detailed ts enclosed , adaptor as per detailed ts enclosed , hydraulic hose msha as per detailed ts enclosed , limit switch for 3 way ball valve as per detailed ts enclosed , ss tube 06 od for miv seal cubicle instrumentation as per detailed ts enclosed , equal tee ss304 for 06 od tube ferrule type pn250 as per detailed ts enclosed , straight coupling ss304 for 06 od tube ferrule type pn250 as per detailed ts enclosed
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - stadium; installation, testing and commissioning ip 67 flood lights 200 watt minimum luminous flux of luminaire 120 lm/w 64 nos, electrical system or installation; serv..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - stadium; providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board 1 n..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - stadium; supplying & laying of pvc insulated and pvc sheathed/ xlpe aluminium power cable (armoured cable) 25 sq mm 250 mt; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - stadium; supplying, installation, testing and commissioning of cubical type indoor/outdoor lt panel board suitable for 415 v 3 phase 4 wire 50 hz ac supply system with ..,repair, maintenance, and installation of
Tender For arm electrical works esic and esis campuses at thathaneri, ponnagaram, maninagaram under madurai region for a period of 12 months - engaging of 1 no charge electricean having c licence holder of day to day maintenance of electrical maintenance works and to monitor these works are properly attended and to take care of complaints arised related to repairs / replacement of damaged fittings / fixtures in the campus such as switches, sockets, switch boards, ht/lt panels , mcbs, mcb dbs, mccbs, sfus, fsus etc., and all types of fans / light fittings, ug cables etc., complete all as directed by the engineer-in-charge. ( 01 no.) (qualification: diploma in electrical engineering with 10 years related experience/iti with 12 years or experience (supervisory) in maintenance job) (qualification: iti certificate with 03 years experience in operation of 11kv / 415v substation and equipment and dg sets along with valid 11kv /415v supervisor permit /c- certificate/grade c-license holder) (higly skilled). he is resposonsible to maintain & update the all logbook of preventive maintenace e&m equipment(lifts,panels,substation,dg sets,fire equipment,ro,stp&etp etc...) with respective staff.[1 no c licence holder ( highly skilled)]. note:-1. he is the responsible for ht metering cubicle to monitor & maintain all parameter readings.2. he is the responsible for timely calibration of ht vcbs, lt acbs/mccbs and earth fault relays and over current relays.3. he is the responsible for ht panels, transformers, acbs, mccbs, apfc panels with connected capacitor banks, power contactors & relays, up keep & maintain records for earth results in the ht & lt installations as per the direction of engr-in-charge.4. during main eb supply failure to monitor the running of stand by dg sets and maintain the plant running record book with all parameters and earth test register & insulation test register, fire alaram, smoke detection and fire fighting register all as directed.5. to maintain the eb shutdown register & obtain the necessary signature from eb authorities . (it should be talley with stand by dg set prrb), engaging lift operator cum electrician for day to day ( 1 shift /day in gen shift) lift operator is responsible for the safe operation of elevators/ lifts.checking of lift condition, to carry out rescue operation and following up with oem for pm & break down calls etc.., to make it in proper working condition etc.., here are some common duties and tasks associated with this roleof lift operator is to assist passengers in safely while loading and unloading and to ensure the safety and comfort of passengers during lift operations.maintenance: operators maintain the lift area, keeping it clean and organized. they also implement emergency procedures when necessary.evacuation: in case of disabled lifts or emergencies, lift operators evacuate passengers as per established protocols.qualification of lift operator: iti electrician with 3 years experience operation & maintain of lifts.- 1 nos (01 lift operator cum electrician for esih thathaneri), engaging electrician cum substaion attendant cum dg operator cum panel opearator for day to day ( in 3 shifts /gen shift) operation of substation, dg sets, lt panels , mcbs, mcb dbs, mccbs, sfus fsus etc and maintenance of electrical works like repairs to internal and external electric supply by replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, lt panels , mcbs, mcb dbs, mccbs, sfus fsus etc and all types of fans/ light fittings, oh lines, ug cables, dg set etc complete all as directed by the engineer-in-charge. and maintain logbooks along with shift register to be updated daily etc to be maintained as directed by engineer-incharge..electrician skilled (iti certificate with 3 years experience)- 4 nos note:1. he will maintain the shut down cum log book register and duly enter all the parameters.2. duri