Web Analytics Made Easy - StatCounter

Diversified Power Plant Stores And Spares Tenders

Get complete information related to latest Diversified Power Plant Stores And Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Diversified Power Plant Stores And Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Diversified Power Plant Stores And Spares Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :41209245 Due date: 04 Aug, 202504 Aug, 2025 5.81 Lacs
Tender For supply of onetime initialrepairfaultclearingservcingand comprehensivemtceofpassengerlift1krexch c c - liftservcie cleaningdoor setting , traction machine repairing , wiring charges mcb , ups lb1000va omglum , lead acid battery 12v 7ah , smpssmpslrs , smt009948vbatterycharging pcb , battery lug for 6sqmm , power monitorting device with single phasing preventer , mcb 50a wo shunttrip4pol , power switching device 18amp , contactor for power switching device , low power switch2co24v dc , load safety device omg lxr , square pb red majestica uparrow , regulated power source omgmw 124 , smt711 single 6pin smd led pcbpmc , positive door contact with clamp , limitswitch actuator , plateropfittingten bolt , plating rope fit stud , traction omg rope 7x193mm ss type , ad liner gutkha assembly for alu bottom , limit switchzv7h23611z1058 , pvcropeclamp10mmassembly , battery12v1dot2ah , landing aluminium bottom track 900mm , adjustable chair type bracket , plating ms stud m10 125 assembly , guide clip for 16mm guide assembly , adjustable counter weight chair type bracket , guide clip for 10mm guide assembly , chemical hit mmplus , pvc tiles 455mm 455mm 2mm , fevicol sr 998 , telephone main unit , telephone hand set unit in side the car , telephone hand set unit at ground floor , labour charges for fixing all items , comprehensive maintenance of 1 no13 passenger lift

State Government

CTN :41250394 Due date: 12 Aug, 202512 Aug, 2025 19.46 Lacs
Tender For re-insulation of 36 nos. of released stator copper bars of 115mw, bhel make generator of unit-1 at varahi under ground power house, hosangadi, kundapura(t), udupi(d). detailed scope of work is described in bid document which is binding on all the bidders.

CTN :41232471 Due date: 07 Aug, 202507 Aug, 2025 4.93 Lacs
Tender For providing of repair and overhauling service - power quality analysis of gpus (qty-11 nos); aircraft ground power unit; yes; buyer premises

CTN :41231185 Due date: 12 Aug, 202512 Aug, 2025 NA
Tender For supply of calibration of meat equipment - base station amdi , test unit flare firing complete , active radar homing emulator , ground station merlin india , battery discharger , tx unit high power single 80w , hot nose thermal enhancement , tx cont aerial synth t1 t6 , fast charger multi outlet

CTN :41225176 Due date: 05 Aug, 202505 Aug, 2025 NA
Tender For providing of repair and overhauling service - ground power unit; gpu; yes; buyer premises

corporations/Associations/Others

CTN :41182838 Due date: 02 Aug, 202502 Aug, 2025 3.92 Lacs
Tender For corrigendum : in order to ensure power supply in the boundary extension/upgraded and newly created bodies under hon'ble chief minister nagar srujan yojana, under electricity distribution section-sarsawa, installation of 45 additional 11 meter pcc electric poles in the low and sunken ground at the long span/road crossing/side of the road of 33 kv lt/ht lines under sarsawa municipal council town area, replacement of worn out wires of lt line from lt line of 400 kva transformer installed at check post sarsawa to sukhija ki chakki, installation of 40 additional 09 meter pcc electric poles in the low and sunken ground at the long span/road crossing/side of the road of 33 kv lt/ht lines under sarsawa municipal council town area and work of installing three phase do fuse set, tpmo and tail less unit on 1 no. 630 kva transformer installed under.

State Government

CTN :40985789 Due date: 11 Aug, 202511 Aug, 2025 3.50 Crore
Tender For corrigendum : purchase of biomechanical lab - force platedimensions (w x d x h) in mm : 600 x 400 x up to 50 number of axes for force measurement: all 3 axes. x,y,z plate should be portable in naturesensor type: piezoelectricsampling frequency-(hz) =1000 hz or more force measured on each axis-fx,fy: 2,000 newton or more, fz: 10,000 newton or more hysteresis- (%fso): 0.5 linearity (%fso) 0.5 crosstalk (%) : 2water resistance rating: ip 50 or better.should be inclusive of installation.should be supplied with carrying case for 2 plates and noise free ups for on-ground assessment. the carrying case should be strong and sturdy.should be able to accommodate portable force plate 9286 ba, daq box 5695 and connecting cablesshould be able to protect the equipment from rain, impact and dust, should have rollers to move easilyshould be able to accommodate an ups also., isokinetic dynamometershould be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric ,eccentric, concentric ,and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees.should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda, nord boardit should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless conne

Central Government/Public Sector

CTN :41184019 Due date: 04 Aug, 202504 Aug, 2025 NA
Location: Goa - Goa Goa - Goa
Tender For supply of portable ground power unit

Central Government And Public Sector

CTN :41146701 Due date: 13 Aug, 202513 Aug, 2025 8.50 Lacs
Tender For renovation of ground floor and mess of maharana pratap hostel of rttc campus in jaipur - group b wiring for light point , wiring for light or power plug with 2x4 sq. mm frls , wiring for light or power plug with 4x4 sq. mm frls , wiring for circuit or submain wiring of size 2 x 1.5 sq mm and 1 x 1.5 sq mm earth wire , wiring for circuit or submain wiring of size 2 x 2.5 sq. mm and 1 x 2.5 sq. mm earth wire , wiring for circuit or submain wiring of size 4 x 2.5 sq. mm and 2 x 2.5 sq. mm earth wire , supplying and drawing of 3 x 1.5 sq. mm sizes of frls , supplying and drawing of 4 x 1.5 sq. mm sizes of frls , supplying and drawing of 5 x 1.5 sq. mm sizes of frls , supplying and drawing of 6 x 1.5 sq. mm sizes of frls , supplying and drawing of 3 x 2.5 sq. mm sizes of frls , supplying and drawing of 6 x 2.5 sq. mm sizes of frls , supplying and drawing of 3 x 4 sq. mm sizes of frls , supplying and drawing of 6 x 4 sq. mm sizes of frls , supplying and fixing of 20 mm size of steel conduit , supplying and fixing of 25 mm size of steel conduit , supplying and fixing two module stepped type electronic fan regulator , supplying and fixing modular blanking plate , supplying and fixing suitable size gi box with 3 pin 5 or 6 amps modular socket , supplying and fixing suitable size gi box with 6 pin 5 or 6 and 15 or 16 amps , providing and fixing of s type or fastner type fan hook , supplying and fixing of 1 or 2 module 75 mm x 75 mm size or modules gi box , supplying and fixing of 3 module 100 mm x 75 mm size or modules gi box , supplying and fixing of 4 module 125 mm x 75 mm size or modules gi box , supplying and fixing of 6 module 200 mm x 75 mm size or modules gi box , supplying and fixing of 8 module 125 mm x 125 mm size or modules gi box , supplying and fixing of 12 module 200 mm x 150 mm size or modules gi box , supplying and fixing 5 or 6 a switch modular , supplying and fixing 15 or 16 a switch modular , supplying and fixing 3 pin 5 or 6 a socket outlet modular , supplying and fixing 6 pin 15 or 16 a socket outlet modular , supplying and fixing modular bell push , supplying and fixing dp sheet steel enclosure , providing and testing ding dong type sound two module call bell , dismentalling of 1200 mm ceiling fan from hostel rooms , itc of above existing 1200mm ceiling fan , dismentalling servicing and complete repairing other than rewinding and itc of 300 mm exhaust fan , dismentalling serviceing and repairing including rewinding and itc of 300 mm exhaust fan , dismentalling servicing and complete repairing other than rewinding and itc of 450 mm exhaust fan , dismentalling serviceing and repairing including rewinding and itc of 450 mm exhaust fan , supplying and fixing 380mm sweep 900 rpm heavy duty tourbo force exhaust fan , sitc ip20 18 20 watt led batten type integrated light fixture , supplying and fixing of vertical type 35 litre capacity 2000 watt water storage electric geyser , supplying and fixing of vertical type 15 litre capacity 2000 watt water storage electric geyser , sitc of ip 40 led surface mounted round smd mid power led 18w downlight , sitc ip20 10 watt led batten type integrated light fixture , sitc of 400 mm sweep oscillating type wall mounted cabin fan , installation of upto 2 tr capacity split ac units , pdg and fixing 1 by 4 inch dia copper refrigerant piping , pdg and fixing 5 by 8 inch dia copper refrigerant piping , provision of top up or additional charging of r-22 or 32 gas , s f suitable size ms stand for placement of split type ac outdoor unit , providing and fixing 20 mm dia heavy duty pvc pipe , supplying and fixing 25 amp moduler type starter , supplying and fixing of 3 x 2.5 sq mm pvc insulated and frls , repairing and painting of existing 3 mtr height galvanised mild steel pole , repairing and painting of existing 7 mtr height galvanised mild steel pole , supply installation testing commissioning of led post top type 27 watt with ip 65 , sitc of 18 watt energy efficient led type 12 inch size pol

CTN :41101150 Due date: 06 Aug, 202506 Aug, 2025 NA
Tender For custom bid for services - defect rectification of acsr 2 (south tower)-defect., in has reported that tracks are not available on display of acsr #2., defect identification., di for the same was undertaken on 13 jun 2025. it was found that the pedestal unit, was required to be replaced to rectify the defect., scope of work to undertake defect rectification., 1. spare part., the required pedestal unit for replacement will be provisioned by in on site. all other, components/ units of acsr #2 should be in place to operationalize the system., 2. manpower., three skilled technicians will be required to undertake the pedestal replacement work., one tower climber also needs to be available on site. the tower climber and two, technicians will be provisioned by hela., 3. material/ machinery., one overhead crane with a loading capacity of one ton lifting to a height of 35 mtrs is, required to undertake the work. the same will be provisioned by in., 4. tools and accessory., the following are required and will be provisioned by hela:-, (a) torque wrench, (b) level indicator, (c) eye hook -02, (d) two 50 mtrs rope, (e) silicon, (f) drill machine, (g) lubricant, (h) slings for lifting, 5. activity to be undertaken., the sequence of events for replacement of pedestal unit will be as tollows:-, (a) disconnect and remove all cables, wave guide ard units from the antennae assembly., (b) fitment of lifting eye hook on antenna and pass lifting slings to the eye hook. dismantle antenna from pedestal unit and keep it on even surface on, the ground with the help of overhead crane. special care is o be undertaken while handling waveguide., (c) hook on the pedestal unit on overhead crane and op an securing bolts, of pedestal unit. lift the pedestal and move to the ground with cap closed of all connectors., (d) hook up new pedestal and lift it to the tower top and w hen aligned with, the position of pedestal plate lower the pedestal on the plate and tight the nut, bolt with level indicator on top of the pedestal to confirm tht the same is at, zero level., (e) lift the antenna to the top of tower and fix it to the pede stal unit., (f) install all units of acsr on top of tower and fix connectors and waveguide to the antenna., (g) switch on power and carry out power checks and fo (hecks., (h) switch on the acsr server and carry out alignment of system to get the tracks appeared on the display., 6. safety., all man working on tower should wear safety belt, safety helmet and safety belt to be, tied on two rigid point at tower top. the man below tower for handlin activity should, wear helmet. the antennae assembly and pedestal unit should be se cured with twopoint safety rope while lifting and lowering the same to avoid any dan age to the man, and material view heavy wind, lifting jerk or swing of the crane sling., .
 Loading, Please wait...

Connect us via What's Up