Get complete information related to latest Door Fitting Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Door Fitting Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Door Fitting Tenders.
Tender For supply of lrcmt01 d d-- gypsy door repair veh ba no 17b 123025m , complete overhauling of engine assy rakshak plus veh ba no 19b 132006w , ac refill labour fitting charge of rakshak plus veh ba no 19b 132006w , ac refill labour fitting charges of 6x mpvy ba no 10r 008926m 12r 009361a 12r 009655m 12r 009592k 13r 009721p 13r 009754k , 2. 5 ton tata doorfitting charge veh ba no 17c 105617l , ecm repair of rakshak plus veh ba no 22b 137322n
Tender For supply of doorfitting items aluminuim and ms d d - alumn door hings 100mm , alumn door hings 75 mm , alumn door hings 50 mm , alumn handle 100 mm , alumn handle 125 mm , alumn handle 150 mm , alumn bow handle 100 mm , alumn sliding door bolt 250mm , alumn slidding door bolt 300 mm , alumn tower bolt 50mm , alumn tower bolt 75mm , alumn tower bolt 150mm , alumn tower bolt 200mm , alumn door stoper double shoes 125 mm , door rubber seal , door rubber seal for snake guard , door stopper with rubber end for wall 150 mm , door stopper for wall , hydraulic door closer , helical door spring 300mm , ms bow handle 100mm , ms bow handle 125mm , ms butt hings 75 mm , ms butt hings 100 mm , ms tower bolt 50mm 12mm dia , ms tower bolt 75mm 12mm dia , ms tower bolt 100mm 12mm dia , ms tower bolt 125mm 12mm dia , ms tower bolt 150mm 12mm dia , ms tower bolt 200mm 12mm dia , ms tower bolt 250mm 12mm dia , ss tower bolt 100 mm round type , ss tower bolt 150 mm round type , paino type hinges 6 feet , paino type hinges 5 feet , paino type hings of open flap width 38,40 mm , ss paino type hings 32 size , ss handle 100 mm , ss handle 125 mm , ss handle 150 mm , mortise door lock handle , ss l drops round nuckle 300 mm , ss l drops round nuckle 250 mm , ss hydraulic floor spring , stainless steel sliding door bolt 300mm , auto close ss hinges for kitchen cabinet ) /bid number: gem/2025/b/6936628 * /dated: 09-12-2025 & & / bid document1 / 58
Tender For execution of repair and renovation works in flat a-1/1, including painting, plaster repairs, sanitary fixtures, kitchen cabinetry, wardrobe works, doorfittings and allied civil works at maurice nagar, university of delhi
Tender For corrigendum : purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp freque
Tender For supply of 4500nos of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure pole [excluding c