Web Analytics Made Easy - StatCounter

Doppler Echocardiography Machine Tenders

Get complete information related to latest Doppler Echocardiography Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Doppler Echocardiography Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Doppler Echocardiography Machine Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :41045026 Due date: 16 Aug, 202516 Aug, 2025 NA
Tender For corrigendum : supply of advanced cardiac output machine hemosphere with non-invasive cardiac output techgnology update

CTN :41165169 Due date: 08 Aug, 202508 Aug, 2025 NA
Tender For corrigendum : supply of cardiac tmt machine (v2) (q2)

CTN :41193488 Due date: 10 Aug, 202510 Aug, 2025 24.00 Lacs
Tender For corrigendum : point of care cardiac and toxicology marker machine

State Government

CTN :41202434 Due date: 31 Jul, 202531 Jul, 2025 24.00 Lacs
Tender For supplu of of point of care cardiac & toxicologi marker machine

CTN :41055288 Due date: 04 Aug, 202504 Aug, 2025 NA
Tender For corrigendum : supply of mechanical bp instrument - anesthesia drug trolley , anesthesia ventilator , cpr equipment for paediatric & adult patients and for training , crico thyrotomy set. , ecg monitor with defibrillator and recorder , endotracheal tubes (different varieties) 4 no. to 8 no. , external cardiac pacemaker , flexible electric heating pad for operation table , flexible rhino laryngo fibroscope with endoscope guide and intubating aid/fibre optic bronchoscope , intubation equipment set (magill's forceps, stillete etc. ) , isoflurane vaporiser , jet ventilator 3.5, 4, 4.5, 5 , laryngeal mask air way no- 3, 4, 2.5, 3.5 , laryngeal spray (local anaesthesia) , endotracheal tubes-adult , endotracheal tubes-pediatric , spinal (lumbar puncture needles) , epidural needles , c v p catheters and catheter for haemodynamic monitoring , i v infusion pumps , stethoscopes , multiple vital sign monitor with ecg, spo2, temperature, nibp etc. , neonal resuscitation unit (trolley) , oxygen percentage monitor , paediatrics anaesthesia circuit with accessories , peak expirator flow meter , peripheral nerve stimulator (neuromusculat transmission monnitor) , pules oximeter , respiratory gas, monitoring equipment with each boyle's apparatus with end tidal co2 (capnograph) , tourniquet with double cuffs , wrights's respirometer , baby warmer , ambu bag paediatium , torch , bougie , air conditioner 1.5 ton , narophagaged airways sizes- 6(female) , narophagaged airways sizes- 7(male) , oropharum airways size 3 (female) , oropharum airways size 4 (male) , oxygen cylinder- e size small , n2o cylinder- e size small , peripheral nerve block nneedle , electrical suction machine , mechanical bp instrument

CTN :41068632 Due date: 05 Aug, 202505 Aug, 2025 NA
Tender For corrigendum : supply of cardiac tmt machine (v2) (q2)

State Government

CTN :40985783 Due date: 11 Aug, 202511 Aug, 2025 1.50 Crore
Tender For corrigendum : purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-a

State Government

CTN :40985787 Due date: 11 Aug, 202511 Aug, 2025 63.00 Lacs
Tender For corrigendum : purchase of biochemistry lab equipments - fully automatic biochemistry analyzerthroughput: 200 photometric tests/hour & 400 tests/hour with ise (optional)reagent positions: 50 cooled reagent positionssample type: whole blood, serum, plasma, urine, csf otherreading volume: 180 lsample volume: 2-70 l (adjustable in 0.1 l)reagent volume: 10-300 l (adjustable in 1 l)light source: halogen lampon board laundry: 6 stage cleaning, 2 stage drying with cuvette validation stepcalibration type: linear, non-linear, multipointprogrammable parameters: default system pack parameters + upto 10 user defined parametersdimensions and weight: ergonomic design and light weight., fully automatic hematology analyzerthroughput-up to 80 samples per hourdimensions and weight ergonomic design and light weighttest mode-cbc, cbc+diffdata storage capacity-up to 100 000 resultscommunication-lan port supports hl7 protocolpower requirement-a.c. 100-240 v, less than or equal to 300 va, 50/60 hzoperating temperature-15 to 30 degree celsiusoperating humidity-30-85%air pressure70-106 kpa, fully automatic immunoassay analyser random assay (hormone analyser)instrument name: immunoassay analyserusage/application-clinicalplate format-random assaydetection method-luminescenceparameters-blood alcohol contentautomation-fully automaticuser input-touchassays-diabetes, thyroid, cardiac, vit d, fully automatic electrolyte analyser-analysis time: 60 second per sample parameters- na , k , cl or ca2+no. of parameters 3 simultaneously90 luser inputs 5 colored touch screen displayelectrode type- sturdy electrode (facility to refill the solution)connectivity 2 usb port, rs232, lisdata storage- 10,000 patient results & 10,000 qc results for 3 levelssample identification- alphanumeric sample idqc management- tri-level quality control, l j plots of last 30 dayscalibration- 2 point calibration on every 4 hours1 point with every samplepower - 100 240 v, 50/60 hz (self adjusting)printer - inbuilt thermal printerroom temperature -15 30 c / 60 90 fhumidity- 85%dimensions and weight - ergonomic design and light weight, centrifuge machine along with 500 prp test tubes (double spin)parameter- neya-16 max speed (rpm)- 15000max rcf (g)- 21000max capacity (ml)- 4 x 175acceleration profiles- 10deceleration profiles- 10display-- multi-color lcdno of programmes- 10 (protected)timer- 30 sec to 99 min & continuous modeergonomic design and light weightsupply - 220v, 50 hz, 1 phasecan be used for extracting prp, autoclavekey features- high-pressure vessel: a high-pressure vessel designed to withstand high temperatures and pressures- temperature control: precise temperature control to ensure effective sterilization- timer and controls: easy-to-use timer and controls for convenient operation- safety features: multiple safety features, such as automatic shut-off and overheat protection, to prevent accidents and ensure safe operationconstruction and materials- stainless steel: a durable stainless steel construction to withstand high temperatures and pressures- insulation: high-quality insulation to ensure efficient heat retention and energy savings- door and seals: a secure door and seal system to prevent steam escape and ensure effective sterilizationperformance specifications- temperature range: 121 c to 134 c.- pressure range: upto 30 psi- cycle time: 15-60 minutes- sterilization capacity in liters or cubic feetsafety standards- compliance with regulations: compliance with relevant regulations, such as asme, fda, and iso standards- automatic safety devices: automatic safety devices, such as overheat protection and low-water cut off, to prevent accidents and ensure safe operation- interlocks: interlocks to prevent door opening during operation and ensure user safetyadditional features- data logging: optional data logging capabilities to track temperature, pressure, and cycle data- printed records: optional printed records of cycle data for documentation and quality control- val

Central Government/Public Sector

CTN :41200108 Due date: 04 Aug, 202504 Aug, 2025 NA
Tender For supply of cardiac tmt machine (v2) (q2)

Central Government/Public Sector

CTN :41201798 Due date: 06 Aug, 202506 Aug, 2025 NA
Tender For supply of triage cardio 3 panel ( trop-i,bnp,ckmb) test cards,catalogue no: 97400eu,for cardiac bio marker instrument,model: triage meter pro,machine serial no : 00100881 ww ( each box conatains 25 tes t kit).make/brand : quidel [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up