Web Analytics Made Easy - StatCounter

Down Commer Repair Tenders

Get complete information related to latest Down Commer Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Down Commer Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Down Commer Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40487495 Due date: 09 Jun, 202509 Jun, 2025 37.43 Lacs
Tender For comprehensive annual maintenance of fire alarm, fire hydrant, fire sprinkler and fire fighting system installed in maha adhivakta building at prayagraj. camc for basement to 5th floor and man-power for 6th to 9th floor

Central Government/Public Sector

CTN :40217801 Due date: 31 May, 202531 May, 2025 NA
Tender For corrigendum : supply of air release valve fire fighting hydrant system

CTN :40359242 Due date: 22 May, 202522 May, 2025 5.01 Lacs
Tender For supply of fire fighting items at ssctps, site store, suratgarh fire bucket 9 liters capacity bucket as per is standard design as per is: 2545 made out of heavy duty g.i. , two way dividing breaching made of light alloy as per is: 5131. , hand controlled branch multi purposes branch (nozzle) the nozzle should be adjustable gallonage with multiple flow settings & 63 mm bim inlet hand nozzle. the nozzle should have selectable flow setting of 115-230-360-475-550 lpm @ 7 bar with flush mode without shut off the nozzle made of pyrolite material, with pistol grip made of zytel and with celcon ball valve. the nozzle shall have feature for straight stream & spray pattern. the length of branch should not , exceed more than 10,5" and weight should not exceed more than 2,5kg, the branch should be simple to operate pattern control (1/4 tum from straight stream to fog). it should have minimum fog angle of 110 and raised lug marks straight stream for limited visibility operations. it should be capable of flushing without shutting down or changing stream patterns. the branch should be nfpa 1964 compliant, fm approved & ce certified, the warranty for branch should minimum five years. be , suction adaptors 100 mm female to 63 mm , instantaneous male, , high range zero torque nozzle specifically designed with ergonomics, handling, control, and reduced firefighter fatigue in mind. in addition, the pistol grip and injet swivel are positioned to eliminate the reaction force torque found in a conventional pistol grip designs. nozzle shall be combination of solid stream and fog nozzle with the capability to flow either stream independently or simultaneously. the solid bore shall have field changeable tips with orifices of either 3/8", ", 5/8", %", 7/8", 15/16", 1", or 11/8" and the fog shall flow. the nozzle shall have spinning teeth, multiple pattern detents, flush without shutting down, twist shutoff of the fog stream, and a full time swivel inlet 2 ", the weight of nozzle not more than 4 kg. the baje shutoff of the smooth bore shall be with dual drive trunnions, the nozzle shall also be constructed of lightweight pyrolite, have a shutoff ball with flow diversion for the fog waterway, have a 05 year warranty and meet nfpa , jet- fog type nozzle, conforming to bs: 336, 63 mm male instantaneous inlet connection, aluminum alloy material with natural finish, operating kg/cm2 pressure-10 , inline foam generator, inlet connection63 mm male instantaneous as per bs 336/is: 903 outlet connection- 63 mm female instantaneous as per bs 336/is: 903, foam induction-3 10 6%, maximum working pressure-10 kg/cm2 , seat washer material neoprene rubber is:937, for hydrant valve , fireman axe as per is: 926, made of forged steel, hardened, and having insulated for fire service use. , fire beater as per is: 8096, made of carbon (mild) steel mesh, and having bamboo handle, suitable for fire-fighting class-a , suction strainer for 100 mm suction hose as per is: 907, , fire hook as per is: 927 with bamboo. , armoured suction hose pipe 100 mm x 4.5 mtr length with gm 100mm male and female round threaded suction hose coupling conforming as per is: 902 , jet-spray shut off type fog nozzle 120 conforming to is:952 63 mm male instantaneous connection, inlet gunmetal material with natural polished, operating pressure-10 kg/cm2 , aluminium foam making branch pipe-fb 5x with g,m 63mm male instantaneous inlet with flow discharge capacity 225 lpm@7kg/cm2 with pvc pickup tube and ss strainer , revolving type branch pipe conforming to is:906 63 mm male instantaneous inlet connection, material gunmetal with natural polished, operating pressure-10 kg/cm2, flow-245 lpm 7kg/cm2 , alloy foam making branch pipe of fb-10x-suitable to discharge 450 lpm@ 7 kg/cm2 (made of aluminium alloy construction) with pvc pick-up tube along with stainless steel dip tube suitable for self-induction , ss 63 mm triple purpose nozzle as per is:2871 , ceramic wool fire blanket white, density-128/m3

CTN :40421713 Due date: 31 May, 202531 May, 2025 NA
Tender For annual rate contract of attending fire fighting water pipe lines hydrant and spray leakages rectification jobs at dpps of u 7 and 8

State Government

CTN :40412253 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For periodical inspection of hydrant base fire fighting system along with fire pump house and conducting mock drill within the hospital premises of ipgmer-sskmh,snph and also to ascertain operational readiness of entire system in case of fire emergency

State Government

CTN :40412337 Due date: 02 Jun, 202502 Jun, 2025 NA
Tender For periodical inspection of hydrant base fire fighting system along with fire pump house and conducting mock drill within the hospital premises of pgpoly, ramrikhh and also to ascertain operational readiness of entire system in case of fire emergency

Central Government / Public Sector

CTN :40225486 Due date: 26 May, 202526 May, 2025 NA
Tender For corrigendum : annual maintenance contract for repair and maintenance of fire fighting equipment at erpl, rajbandh - amc for repair and maintenance of f&s eq, carrying out maintenance and inspection of fire extinguishers on monthly basis including pastings/ marking of maintenance date, clea ning, condition of threads of caps, discharge tubes, sharpness of piercing pin and cylinder body, replacement of defective parts ( iocl supplied), measuring weight and charges for labour, including oiling, greasing, testing as per direction of eic inclusive of al l tools &tackles, consumables, transportation, labour charges etc and measuring instruments for the same as directed by the eic/ si te engineer and submitting the reports of the inspection as per hse manual format (payment of spares not supplied by iocl shall be m ade as per respective items), for 10/9 kg. capacity dcp extinguisher, for 75/70/50 kg. capacity dcp extinguisher, for 4.5 kg. capacity co2 extinguisher, for 6.5 kg. capacity co2 extinguisher, for 2 kg capacity clean agent extinguisher, monthly: checking, inspection, maintenance, greasing, cleaning, oiling, replacement of disc washer, blank cap if any including compl ete overhauling etc. of double headed hydrant valves alongwith all tools, tackles, manpower, material etc. payment for disc washer, coupling washer & blank cap shall be made separately., supplying and fitting of hydrant disc washer as per directions of engineer-in-charge, supplying and fitting of fire hydrant/ fire hose coupling washer, supply and fitting of blank cap (as per is 5290 , red colour with gi chain) suitable for 63 mm hydrant outlet as per direction of ei c, supplying & fitting spindle assembly (gunmetal), repair of adaptor lug of hydrant/ hose inclusive of tools tackels & labour etc., monthly maintenance of 750 gpm monitors: oiling & greasing through grease nipple provided on bearing, worm wheel and worm shaft, cle aning, performance checking for complete vertical and horizontal movement, nozzle movement, water throw, foam suction, ensuring prop er tightning of flanges, clearing the debris around the nozzle etc as per approved procedure including tools & tackles, report submi ssion complete as per direction of site engineer / eic. water resistant low friction synthetic grease, grease gun and all other cons umable etc shall be arranged by vendor. after testing, afff jerry-can must be positioned and replinished near monitor including shif ting, transportation etc., cleaning, maintenance and repair of water cum foam monitor nozzle for fog jet operation by opening and dismantling of nozzle cleanin g by rustoline or kerosene of all the components thoroughly, further inspection of internal parts in the presence of the engineer-in -charge, repair/reconditioning by hand facing, machining, grinding, lapping, etc. and greasing,& reassembly in foam monitors as per direction of eic inclusive of necessary tools, tackles and labour., opening of blind flange of water curtain system of control building, sr tank cleaning of water line, dechoking of spray nozzles, ref ixing it with after testing with new gasket.etc of water spray system of all buildings (on monthly basis) including nozzle dechoking , strainer cleaning and all labour, tools & tackles complete as per direction of the site engineer/ eic. (rates per blind opening), valve maintenance : checking, inspection, greasing, cleaning, oiling etc. of all fire water valves, of all sizes upto 14" including grease and all labour, tools & tackles complete as per direction of site engineer / eic and provided by contractor. all such valves shall be fully closed and opened and restored in origional condition as per advise by eic/ site engineer.note: the valve sizes may vary from 3" to 14". rates are per valve., hydrotesting of fire fighting delivery hose of dia 63 mm on half-yearly basis (type a and b ) by making arrangement of hydraulic pum p, blind, shifting from plant area, bui

State Government

CTN :40394379 Due date: 09 Jun, 202509 Jun, 2025 NA
Tender For supplying manpower round the clock for operation of fire pump and periodical inspection of hydrant and sprinkler base fire fighting system along with fire pump house and conducting mock drill within 100 beded covid wards premises of kharagpur sdh

State Government

CTN :40367917 Due date: 30 May, 202530 May, 2025 80.77 Lacs
Tender For supply, installation, testing and commissioning of fire fighting arrangement with hydrant including construction of pump house and permanent restoration by paver tiles damaged due to laying of underground ms pipe in and around tarakeswar temple compl

State Government

CTN :40060123 Due date: 28 May, 202528 May, 2025 2.09 Lacs
Tender For corrigendum : supply of mather and platt make fire hydrant pump spares - shaft, p/n:49, for fire hydrant/spray pumps for fire fighting system, impeller nut, p/n:442, for fire hydrant/spray pumps for fire fighting system, spacer sleeve, p/n:287, for fire hydrant/spray pumps for fire fighting system, shaft sleeve, p/n:286, for fire hydrant/spray pumps for fire fighting system, o ring for sleeve, p/n:775-1, for fire hydrant/spray pumps for fire fighting system, external circlip p/n:454,f/pump et-iso32, matter and platt make fire hydrant pump et-iso-32 support foot, part no.: 23, fire hydrant pump bearing house with provision for grease/oil filling, model:et-iso-32.
 Loading, Please wait...

Connect us via What's Up