Web Analytics Made Easy - StatCounter

Dp Transmitter Tenders

Get complete information related to latest Dp Transmitter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dp Transmitter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dp Transmitter Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45712862 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For tender for supply of transmitters - dpt , standard , hart , range -10000 mmwc to 10000 mmwc , diaphragm gold plated on ss316l , as per data sheet mrpl inst dpt 003. , dpt , standard , hart , range -1000 mmwc to 1000 mmwc , diaphragm gold plated on ss316l , as per data sheet mrpl inst dpt 004. , high pressure dp trans , ty hart , gold plated diaphragm , rang 0 to -10000mmwc , as per specification sheet mrpl dpt 006 , ff diffrential pressure transmitter range -10000 to 10000 mmwc , as per spec sheet mrpl inst dpt 012 , ff diffrential pressure transmitter range -1000 to 1000 mmwc , as per spec sheet mrpl inst dpt 013 , dpt , standered , ff , range -50000 mmwc to 50000 mmwc , diaphragm gold plated on ss316l , as per data sheet mrpl inst dpt 014. , diff. pressure transmitter , type-remote seal , range 0-10000mmwc , flange rating 3 inch 600 , as per spec sheet mrpl rsdp 001 , diff. pressure transmitter , type-remote seal , range 0-10000mmwc , flange rating 3 inch 150 , mrpl rsdp 002 , dpt , remote seal , hart , range 0-50000 mmwc , diaphragm ss316l , flange rating 3 inch 300 , as per data sheet mrpl inst rsdp 004. , dpt , remote seal , hart , range 0-10000 mmwc , diaphragm ss316l , flange rating 3 inch 300 , as per data -r sheet mrpl inst rsdp 003. , dpt , flush mounted diaphragm , hart , range 0-1000 mmwc , diaphragm ss316l , flange rating 3 inch 150 , as per data sheet mrpl inst rsdp 014. , dpt , flush mounted diaphragm , hart , range 0-25000 mmwc , diaphragm ss316l , flange rating 3 inch 150 , as per data sheet mrpl inst rsdp 015. , hart pressure transmitter , range 0-35kg cm2 , as per specification sheet mrpl pt 001 , high pressure trans , ty hart , gold plated diaphragm , rang 0 to 320 kg cm2 , as per specification sheet mrpl pt 006 , hart pressure transmitter , range 0-320 kg cm2 , as per specification sheet mrpl pt 005. , pressure transmitter , range 0-35 kg cm2 , direct mounted 1.5 inch 300 as per spec mprl inst rspt 009 , dpt , standard , hart , range -10000 mmwc to 10000 mmwc , diaphragm hastelloy c-276 , as per data sheet mrpl inst dpt 005. , pt , remote seal , hart , range 0-35 kg cm2 , diaphragm ss316l , flange rating 2 inch 300 , as per data sheet mrpl inst rspt 001. , pt , remote seal , hart , range 0-140 kg cm2 , diaphragm ss316l , flange rating 2 inch 600 , as per data sheet mrpl inst rspt 002. , pt , remote seal , hart , range 0-35 kg cm2 , diaphragm ss316l , flange rating 2 inch 150 , as per data sheet mrpl inst rspt 003. , pt , remote seal , hart , range 0-140 kg cm2 , diaphragm ss316l , flange rating 2 inch 300 , as per data sheet mrpl inst rspt 004. , pt , remote seal , ff , range 0- 35 kg cm2 , diaphragm ss316l , as per data sheet mrpl inst rspt 006. , wireless temperature transmitter as per spec mrpl inst wtt 001 , wireless dpt , flush mounted diaphragm , hart , range 0-25000 mmwc , diaphragm ss316l , flange rating 3 inch 150 , as per data sheet mrpl inst wrs 001. , wireless dp transmitter , dp range -10160 mmwc , as per spec. , wireless pressure transmitter , range 0-40 kg cm2 g , as per spec. , wireless gateway for communication with dcs pc , as per spec. , wireless hart adapter , ff , dpt , flush mounted diaphragm , range 0-25000 mmwc , diaphragm ss316l , flange rating 3 inch 150 , as per data sheet mrpl inst rsdp 017. , hart dp transmitter , range -10000mmwc to 10000 mmwc as per specification sheet mrpl dpt 001. , hart dp transmitter , range -1000mmwc to 1000 mmwc as per specification sheet mrpl dpt 002. , dpt , high static pressure , hart , range -10000 mmwc to 10000 mmwc , diaphragm ss316l , as per data sheet mrpl inst dpt 007. , dpt , high static pressure , hart , range -50000 mmwc to 50000 mmwc , diaphragm ss316l , as per data sheet mrpl inst dpt 009. , dpt , standard , hart , range -100 mmwc to 100 mmwc , diaphragm ss316l , as per data sheet mrpl inst dpt 010 , dp transmitter , as per spec , mrpl inst dpt 015 , dpt , remote seal , hart , range 0-50000 mmwc , diaphragm ss316l , flange rating 1.5 inch

Central Government/Public Sector

CTN :45118858 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For corrigendum : procurement of oil module and its mandatory spares for 1x800 mw yamunanagar project - motor terminal block  ac aop motor , motor terminal block  for ac jop motor , motor terminal block  for ac ove motor , "motor terminal block  for dc eop motor (1 set = 2 nos.)" , "motor terminal block  for dc jop motor (1 set = 2 nos.)" , "space heater  for ac aop motor (1 set = 2 nos.)" , "space heater  for ac jop motor (1 set = 2 nos.)" , "space heater  for ac ove motor (if not applicable then space heater for acjop to be provided) (1 set = 2 nos.) " , "space heater for dc eop motor (1 set = 2 nos.)" , "space heater for dc jop motor (1 set = 2 nos.)" , bearings for motor for lube oil pump (aop) , bearings for motor for acjop , bearings for oil vapour exhauster motor , bearings (de and nde) for dc eop motor , bearings (de and nde) for dc liop motor , carbon brushes for dc eop motor , carbon brushes for dc jop motor , brush assemblies for dc eop motor , brush assemblies for dc jop motor , ac motor for lube oil pump (aop) , ac motor for lifting oil pump (jop) , oil vapour exhauster motor , dc eop motor , dc liop motor , lube oil tcv actuator , lt for oil module –m(850-1750 mm) , pressure switch index-d (0.5 - 10 bar) , dp transmitter lube oil filter , rtd (0 to 100°c) for oil module , level gauge for oil module , local gauges (0-10 bar) -oil module , local gauges (0-400 bar) -oil module , pressure gauge ((-)120-0 mbar) -oil module , temperature indicator (0-100 degc) , pr. transmitter range (0-250 bar)-oil mod , pr. transmitter range (0-6 bar)-oil mod , pr. transmitter range (0-(-120) mbar)-oil mod

State Government

CTN :45157993 Due date: 02 Jul, 202602 Jul, 2026 10.56 Lacs
Tender For corrigendum : procurement of diaphragm type dp transmitter installed at debris filter of unit no. 1 to 4, 4x210 mw, htps, korba west.

CTN :45592174 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For supply of laboratory and scientific equipment - supply of laboratory and scientific equipment, rheometer (details as per list at annexure-a)

CTN :45557713 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For dp transmitter for level measurement

Central Government/Public Sector

CTN :45432406 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For corrigendum : supply of ball valve 4by2-way g1by2 pn500 , dpac-s hp pilot valve , achp prv 1by4 inch bspf 0.5-10 bar r13614 , achp 3by8 midi pressure regulator , achp 6.0 mm nrv cvh1-h6m6m , dpac-s hp cover seal 109x103.4x5.6 mm , r-cp filter element hp054-1-f , r-cp filter element hp054-1-s , achp d.p. transmitter dmt 143 , installation and repair of air dryers

CTN :45331116 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For bid to ras supply of bending beam rheometer , 1st year preventive maintenance visit , 2nd year preventive maintenance visit , 3rd year preventive maintenance visit

State Government

CTN :45512134 Due date: 02 Jul, 202602 Jul, 2026 4.00 Lacs
Tender For pmkit cytoflex , collagen type 1 , adenosine 5 diphosphate sodium salt , quarts plate for rheometer , erba h 560 calibrator

CTN :45416327 Due date: 16 Jun, 202616 Jun, 2026 11.00 Lacs
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
 Loading, Please wait...

Connect us via What's Up