Get complete information related to latest Dpx Mountant Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dpx Mountant Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dpx Mountant Tenders.
Tender For led based hour - rpm meter. 4 digit seven segment digital output for rpm; 6 digit seven segment digital output for hour meter; range: 0 to 3000 rpm; input: mpu signal; aux power supply: 18v to 32 v dc; number of teeth: 142. (factory programmable); mechanical dimension: bazel: 96 x 96 & panel cut-out: 92 x 92; depth: 85 mm approx. suitable for cil engines. make: twintech/cummins/process care systems/data care system. note: the firms with past performance of the tendered/same items subject to submission of proof of documents such as pos/r note are only eligible.
Tender For annual rate for various item of material supply and labour for road and building works. - earthwork for embankment including breacking clods, dressing with all lead and lift. (excluding watering and consolidation from borrow pits within land width., earthwork for embankment including breacking clods, dressing with all lead and lift. (excluding watering and consolidation from borrow pits within 0.50km, earthwork for embankment including breacking clods, dressing with all lead and lift. (excluding watering and consolidation from borrow pits within 1.00km, earthwork for embankment including breacking clods, dressing with all lead and lift. (excluding watering and consolidation from borrow pits within 2.00km, rolling of earth work in layers with power roller including filling in depression which occur during the process., watring of earth work in layers with power roller including filling in depression which occur during the process., earthwork in cutting including preparing the slope and camber and stacking or utilising the cutting stuff in bank as directed upto 200 meter from the end of cutting with all lead and lift. (i) soft murrum, earthwork in cutting including preparing the slope and camber and stacking or utilising the cutting stuff in bank as directed upto 200 meter from the end of cutting with all lead and lift.(ii)hard murrum, box cutting the road surface to proper slope and camber for making a base for road work including removing the excavated stuff and depositing on the road side slopes as directed upto 50mts. lead., supplying of graded stone agg. of following sizes (for w.b.m. road) (at quarry) (a) hand broken stone agg. 40mm to 63mm size., supplying of graded stone agg. of following sizes (for w.b.m. road) (at quarry) b) hand broken stone agg. 25mm to 90mm size., carting charge of hand broken stone agg. with own vehicle as directed.0/0 to 1/0 km., carting charge of hand broken stone agg. with own vehicle as directed. 0/0 to 2/0 km., carting charge of hand broken stone agg. with own vehicle as directed. 0/0 to 3/0 km., carting charge of hand broken stone agg. with own vehicle as directed.0/0 to 4/0 km., carting charge of hand broken stone agg. with own vehicle as directed. 0/0 to 5/0 km., carting charge of hand broken stone agg. with own vehicle as directed. above 5 km and upto 10km., carting charge of hand broken stone agg. with own vehicle as directed. above 10km and upto 15km., carting charge of hand broken stone agg. with own vehicle as directed. above 15km and upto 25km., carting charge of hand broken stone agg. with own vehicle as directed. above 25km and upto 50km., supplying of crushed stone agg. chipping etc. of hard stone of following nominal size, free of desintegrated pieces, deletarious and organic matter (for bitumen surface dressing etc.) and grading as per i.r.c. code) at quarry. (a) 40 to 63mm size., supplying of crushed stone agg. chipping etc. of hard stone of following nominal size, free of desintegrated pieces, deletarious and organic matter (for bitumen surface dressing etc.) and grading as per i.r.c. code) at quarry. (b) 40mm size., supplying of crushed stone agg. chipping etc. of hard stone of following nominal size, free of desintegrated pieces, deletarious and organic matter (for bitumen surface dressing etc.) and grading as per i.r.c. code) at quarry. (c) 25 to 40mm size., supplying of crushed stone agg. chipping etc. of hard stone of following nominal size, free of desintegrated pieces, deletarious and organic matter (for bitumen surface dressing etc.) and grading as per i.r.c. code) at quarry. (d) 12 to 20mm size., supplying of crushed stone agg. chipping etc. of hard stone of following nominal size, free of desintegrated pieces, deletarious and organic matter (for bitumen surface dressing etc.) and grading as per i.r.c. code) at quarry. (e) 20mm size., supplying of crushed stone agg. chipping etc. of hard stone of following nominal size, free of desintegrated pieces, deletarious and org
Tender For corrigendum : tender for purchase of pathology materials-reagents and consumables for nmmc hospitals (for year 2025-26-2026-27) - 75 test cartridge for blood gas analyser gem premier 3000, bulb for microscope 6 v / 20w, capillary for bt-ct ( 1 x 100 no), copper sulphate powder (500 gm), coverslips 22x22mm x10 gm, coverslips 22x30mm x10 gm, diamond marker ( glass cut pencil), distilled water biochemistry gr ( 1 x 5000 ml), e.s.r. pipette western green (glass), e.s.r. stand (12 tube metal body, press button type ), falcon tube 50 ml sterile, fields stain a ( 1 x 500 ml), fields stain b ( 1 x 500 ml), filter paper ordinary ( 1 x 100 sheet), handiplast (round) for blood donors, heam test kit ( 1 x 200 test), heavy liquid paraffin oil (1x 500 ml), high power lens (40x) for labomed microscope, low power lens (10x) for labomed microscope, immersion oil ( 1 x 100 ml), lancet, lens cleaning paper ( 1 x 100), methanol based slide fixative ( 1 x 500 ml), micro pipette fix volume 10ul, micro pipette fix volume 50ul, micro pipette fix volume 100ul, micropipette fixed volume 1000 l, micro pipette variable volume 100-500ul, micro pipette variable volume 10-100ul, micro pipette variable volume 5-50ul, micro pipette variable volume 100-1000ul, micropipette non digital variable volume 0-100 ul, microscopic glass slides (1 x 50 slides), multichannel pipette, n/10 hcl (500 ml), neubaur chamber (bright line), oil immersion lens with adapter for labo/labomed microscope, phenyl crystal 99.5% (500 gm), sodium hypochlorite (5% diluted) ( 5 lit jar), sterile swab sticks for culture sensitivity ( 1 x 100 swab sticks), sulphuric acid 98 % ( 500 ml), temperature recording circular chart papers (-)100 c to (+)100 c, temperature recording circular chart papers (-)50 c to (+)50 c, temperature recording circular chart 0 c to 40 c, temperature recording pen, test tube 3 x 11mm, test tube 4 x 11mm, thermal paper roll (57 mm x 30 m) for printer (1kit = 03 roll), thermal paper roll (56 mm x 30 m) for printer (1kit = 03 roll), 50 mmx25mm ch 1000 lablles x 1 roll (for fully atomated urine analyser, 55 mm x 300 mts wax (for fully automated urie analyser), thermometer (-)10 c to (+)100 c, thermometer (-)100 c to (+)100 c, tips for micropipette 200 l yellow tips ( 1 x 1000 tips), tips for micropipette 500 l blue tips ( 1 x 1000 tips), tips for micropipette 1000 l, tourniquet, whatman filter paper ( 1 x 100 paper), retic stain (10 ml), litmus paper ( 100 numbers), coplin jar 60 ml capacity plastic material, coplin jar 60 ml capacity glass material, bariun cloride 500 ml, selvinoffs reagent 500 ml, fructose reagent 500 ml, dpxmountant 500 ml, grams stain kit, naoh (0.1 n) 500 ml, spirit lamp, semen diluting fluid (100 ml), leugols iodine 100 ml, tissue roll, giemsa stain(1x500ml), slide preservation box for 100slides, slide staining cradle, slide drying rack, slide rack, deionised water (5lit), wooden spatula, blood collection needle holder, multi sample needle 22 g, non vaccum blood collection tubes pet material edta (k3), 3-5 ml, rubber stopper & plastic cap of lavender colour, non vaccum blood collection tubes pet material fluorude 3-5 ml, rubber stopper & plastic cap of gray colour, non vaccum blood collection tubes pet material plain with clot activator, 3-5 ml, rubber stopper & plastic cap of red colour, sputum container( 30 ml transparant, pp material, screw cap.), urine & stool container 50ml with lid (specimen container), vaccum blood collection tubes pet material gel with clot activator tube 3-5 ml rubber stopper & plastic cap of golden/yellow colour, vaccum blood collection tubes pet material edta (k3),3-5 ml rubber stopper & plastic cap of lavender colour, vaccum blood collection tubes pet material fluorude , 3-5 ml rubber stopper & plastic cap of gray colour, vaccum blood collection tubes pet material plain tube with clot activator 3ml rubber stopper & plastic cap of red colour, vaccum blood collection tubes pet material sod
Tender For empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20
Tender For providing of custom bid for services - calibration of uv light meter for 3 years used in process shop as per the qms and regulatory requirements
Tender For corrigendum : supply of supply of consumables /implants /devices/accessories, on consignment basis for ctvs - ventilator, invasive pressure monitoring, iv drip sets, anticoagulation monitoring and airway consumables, bain circuit adultbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., bain circuit pediatricbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., corrugated tube connectorshould allow connection between all breathing circuits and the et tube connector.thecorrugatedtubeshouldbeexpandable.shouldallowmovementofbreathingcircuitatpatientend.should be made of medical grade pvc.should be compatible with ett and tracheostomy tube., micro aggregate blood filter for red cell transfusionfilter media should be 40 micron rated polyester screen media with uniform pore sizeshould have total filter surface area of 170 sq.cmshould have average capacity of filtering 10 units of blood., packed red cell & whole blood leucocyte reduction filters.bedside filtration of one & two unit of packed red blood cells or whole bloodshould have universal spike with microbiological recovery ventshould be with attached straight administration set/automatic self leveling drip chamberperformance should consistently average less than 2x105 residual leukocytes per unitred cell recovery should average greater than 90%.filter housing hold up volume should be 25ml for one unit filter and 35ml for two unit filterit should be single use, forced warming blanketshould be disposable and two layered; should consist of non woven propylene fabric for body warming. should be usable with forced air warming units. material should be latex free and should meet flammability standard 16 cpr 1610 for safety. the manufacturer must have all the below listed types of blankets and should quote the prices separately for separate blankets full body adult underbody adult with arm and head openings pediatric full body pediatric underbody blanket. should be compatible withcommon machines. should be ce certified, cuff inflator and pressure gauge itisusedtoinflate& preciselymonitorthecuffpressureofet tube, tracheostomy tube and lma cuff. reducetheriskofpressurenecrosisandmucosal ischemia theriskofaspirationcanbeavoidedeliminatestheuseofsyringestoinflate&deflatethecuffs. should have release valve to adjust the pressure. gaugecalibratedincmh2owiththedetachablelongconnecting tube. shouldhaveinflationbulbfortheinflationofthecuffshouldhavethehookatthebackoffitsintostandardrail.should have widely spaced scale markings with colour coded pressure ranges.ergonomiconehadoperation, intubation pillow reusable intubation pillow for head elevated laryngoscopy position (help) for airway management of obese &l arge framed patients. shouldbemadeupofdensefoam. shouldbesuppliedwithheadcradle shouldbevinylcovered shouldbecemarked, negative insipratory force meter should be disposable, compact, light weight & amp;single patient use negative inspiratory force meter to check the negative inspiratory force of the ventilated patients with the facility of memory indicator point ertore cord reset highest force achieved by the patient individually packed ready for use. shouldbe ,ce marked, capnography co2 sampling mask shouldhavetheprovisionforbreathtobreathmonitoringforboth nose & mouth should have the facility to deliver oxygen; allow sampling of exha