Web Analytics Made Easy - StatCounter

Drinking Water Pipeline Tenders

Get complete information related to latest Drinking Water Pipeline Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Drinking Water Pipeline Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Drinking Water Pipeline Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45734668 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For state plan 2023 24 replacing old ac transmission line from chala gl tank to chinmaya college bus stop with 250 mm di pipe and at chala temple road with 160 mm pvc pipe pipe line replacement work pipeline work

State Government

CTN :45744002 Due date: 07 Jul, 202607 Jul, 2026 1.99 Lacs
Tender For nali nirman avm pvc pipe line nirman kaary sadak ke dono taraf kajod sain ke ghar se mukhay chauk ki aur yalsar

State Government

CTN :45732656 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For providing and fixing pvc bend 100mm x 90 degree / jointing for new pipe line connection for jan samwad complaint at village barhana milwan. , jointing for new pipe line connection for jan samwad complaint at village barhana milwan , providing and fixing tee 4x4x4 mm, for new pipe line connection for jan samwad complaint at village barhana milwan

corporations/Associations/Others

CTN :45729056 Due date: 13 Jul, 202613 Jul, 2026 1.50 Lacs
Tender For providing pvc distribution pipe line (90 mm pvc pipe) at ward no. 24,25,27 in adirampattinam municipality

Central Government/Public Sector

CTN :45713891 Due date: 20 Jul, 202620 Jul, 2026 20.00 Lacs
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20

Central Government/Public Sector

CTN :45713851 Due date: 25 Jul, 202625 Jul, 2026 55.00 Lacs
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole

CTN :45738540 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For supply of 10 pair ug jf communication cable , station line module analog board , l3 poeplus managed switch with integrated sfp transceiver modules , 12 core sm ofc cable , hdpe pipe , 2 pair pvc telephone cable , cat 6 utp cable , pvc conduits including laying of cat6 cable and 2 pair pvc telephone cable 2000 mtrs , 24 port loaded cat 6 utp patch panel , rj11 rj45 i o boxes , 4 port spu lpu , 5a 0 25a glass fuses , cable route markers joint indicators , excavation of trenches cat 6 utp cable 2150 mtrs , laying of 10 pair armoured communication cable laying of hdpe pipe laying of ofc cable 3250 mtrs , fixing and dressing of 12 nos of 6u network racks , 24 port fiber liu , 9u network rack , ofc patch cords of 2m length , cat6 patch cords 0f 2m length , provision of additional structured cabling in 10 work centers of cas as per scope of work , shifting of network rack end termination of telephone and cat6 cables and dressing of all cables splicing etc in e f facility , 20 pair weatherproof telephone junction boxes , open stage hfa ip phones with perpetual gateway licenses , digital handsfree telephone cli , installation commissioning programming and testing of above all items and provision of additional structured cabling for 01 year for any newly added

CTN :45741430 Due date: 30 Jul, 202630 Jul, 2026 NA
Tender For provision of individual over head pvc tank with steel staging and pipe line for staff quarters at kharagpur under jurisdiction of aen/water works/kharagpur.

CTN :45533769 Due date: 07 Jul, 202607 Jul, 2026 9.44 Lacs
Tender For corrigendum : line no 02 ward no 01 shahpur tigri evam chaitiya farm ke aas pass ki vibhinn galiyon main 110 mm vyas ki pvc pipe line bichane evam jodne ka karye.

CTN :45533798 Due date: 07 Jul, 202607 Jul, 2026 9.94 Lacs
Tender For corrigendum : line no 01 ward no.01 basant vihar evam khushhalpur ki vibhinn galiyon main 110 mm vyas ki pvc pipe line bichane evam jodne ka karye.
 Loading, Please wait...

Connect us via What's Up