Get complete information related to latest Drum Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Drum Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Drum Pump Tenders.
Tender For supply of brake buster with master cylinder , brake pipe line master cylinder to bs pump , brake shoe rear both side complete set , hand brake cable rh , hand brake cable lh , hand brake cable front , rear road spring bush complete both side , shackle pin rear both side , road spring bolt rear , u bolt , nut , rear both side shock absorber assy , front both side shock absorber assy , both side upper arm bush 4 nos , anti role bar balancing rod both side , anti role bar balancing rod bush , damper pad both side front , torsion bar adjusting nut and bolt , centre bearing rubber bush , u j cross , lower coloum assy , front crank timing oil seal , timing oil seal , timing belt , front left axle assy with dust boot , front right axle assy with dust boot , tube oil seal both side front axle , pin shaft , left side roller bearing tube axle , right side needle bearing tube axle , thrust washer axle shaft , packing 4 by 4 , synthetic bush small , synthetic bush big , synthetic packing upper and lower , air filter , split pin , nut bolt size no 12 , assy vacuum pump decor , bulb 1141 , bulb 67 , windshield water reserve pipe , 4 pin relay big type starter heavy duty , 4 pin relay small , starting relay , 4 pin relay big , fuse 15 or 20 normal size 4 plus 4 , wheel sensor front , wheel sensor rear , fog light bulb 12 volt , wiper blade , rubber biding complete set , rear lift side door lock inner and outer complete set + /bid number : gem/2025/b/6350565 , /dated: 16-06-2025 ( ( / bid document 1 / 41
Tender For corrigendum : supply of exhaust fan with motor - exhaust fan with motor , oil filter , rope asseembly , carburator assembly , fuel cock , pump gasket , spark plug
Tender For supply of laboratory instrument for lab work in phe sub division jabalpur sihora kundam-, , bacteriological incubator, , hot plate, , ph meter, , spectrophotometer, , quartz cuvette 10 mm make - systronics, , distilling apparatus with friedrichs condenser, interchangeable joint and stopper capacity 2 ltr. make - borosil, , laboratory refrigerator, , sample bottel 125 ml make - borosil, , burette 50ml with boroflo stopcock, class a nabl certified, make - borosil, , burette 50ml with boroflo stopcock, amber class, , a nabl certified, make - borosil, , volumetric flask 500 ml class a, clear, with, , nabl certified make - borosil, , volumetric pipette 25 ml class a, nabl certified, , make - borosil, , volumetric pipette 50 ml class a, nabl certified, , make - borosil, , volumetric pipette 100 ml class a, nabl certified, , make - borosil, , graduated pipette 5 ml class a, nabl certified, , make - borosil, , graduated pipette 10 ml class a, nabl certified, , make - borosil, , nessler tube stand 50 ml, , nessler tube stand 100 ml, , pipette stand, , thermometer 110 c with nabl certificate, , wide mouth bottle 1000 ml plastic, , funnel 75 mm plastic, , funnel 75 mm make - borosil, , conical flask 150 ml make - borosil, , conical flask 250 ml make - borosil, , beaker 100 ml make - borosil, , beaker 250 ml make - borosil, , beaker 500 ml make - borosil, , beaker 2000 ml make - borosil, , automatic burrette pump, , whatman filter paper 42 no., , nessler tube 50 ml make - borosil, , nessler tube 100 ml make - borosil,
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f
Tender For corrigendum : supply of element xr hr icp ms consumables as per attached specifications - glass ring cd2 quartz material no_1136500 , shield torch icp2 material no_ 1126640 , filter cartridge material no_1190400 , oil prevac pump p 3 - 3 ltrs material no_ 1094301 , fitting material no_ 1135670 , sample cone icp , nickel material no_1044530 , sample cone, ni-jet version material no_1260630
Tender For construction of sub marsible pump drinking water with filter and soak pit near beldanga club mouza jotkabir jl no 126 plot no 19 under dhumpur gram panchayat.
Tender For construction of sub marsable pump drinking water with filter and with sokpit west the house of jogen mahato mouza khanpur , j.l.no. 131,plot no. 98 tied under dhumpur gram panchayat.
Tender For provn of high efficiency particulate air filter for operation theatre of 65 mh provn of solar water pump and connected items in e zone addn altn of electrical wiring and connected items in building no op t 430 in r zone, provn of 55 x exhaust fan in jco
Tender For procurement of medical consumables items for use by the department of cardiovascular and thoracic surgery, goa medical college - adult membrane oxygenator with hard shell reservoir 1. should have heparin free, hydrophilic polymer surface balance coating. 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 4000ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 7 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 1/2" membrane surface area 1.8 to 2.5m210. should have sampling port.11. us fda and ce approval is required., adult membrane oxygenator with hard shell reservoir with integrated arterial filter 1. should have heparin free, hydrophilic polymer surface balance coating. 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 4000ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 7 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 1/2" membrane surface area 1.8 to 2.5m210. should have sampling port.11. us fda and ce approval is required., small adult membrane oxygenator with hard shell reservoir 1. should have a micro porous hollow fiber membrane oxygenator 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 3500ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 4 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 3/8" 10. should have sampling port.11. us fda and ce approval is required., small adult membrane oxygenator with hard shell reservoir with integrated arterial filter 1. should have a micro porous hollow fiber membrane oxygenator with integrated arterial filter2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 3500ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 4 ltr/min.5. should have priming volume less than 200ml6. should have high efficiency heat exchanger positioned in post pump configuration.7. venous return port 1/2" with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8" venous inlet 3/8" 10. should have sampling port.11. us fda and ce approval is required., paediatric membrane oxygenator with hard shell reservoir 1. should have a micro porous hollow fiber membrane oxygenator 2. should have open circuit configuration 3. should have hard shell venous reservoir of capacity more than 3500ml. with built of cardiotomy reservoir with 30m filter capacity.4. should have blood flow range 0.5 ltr to 3.5ltr/min.5. should have priming volume less than 140ml6. should have high efficiency heat exchanger position in post pump configuration.7. venous return port 3/8" with rotating facility and reducers8. should have an auto vent facility.9. pot size : arterial outlet, venous outlet 3/8" venous inlet 3/8" with reducers10. us fda and ce approval is required., paediatric membrane oxygenator with hard shell reservoir with integrated arterial filter 1. should have a micro porous hollow fiber membrane oxygenator with integrated arterial filt
Tender For rdf based downdraft gasifier system - shredder, weighing scale, hopper (big conical type), material holder (small cylindrical type), knife edge gate valves, downdraft gasifier, air blower, gas suction blower, hot gas cyclone, heat exchanger, venturi scrubber, gas liquid separator, packed bed column and water tank with alkali dosing system and recirculation pump, water pump, filter, gas flaring unit, erection, commissioning and performance test charges