Get complete information related to latest Duck Foot Bend Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Duck Foot Bend Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Duck Foot Bend Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45642680 Due date: 13 Jul, 202613 Jul, 2026 29.44 Lacs
Tender For supply of supply of package type air conditioning plants of 16.5 ton capacity at akashvani rampur. equipment consisting compressor unit, air cooled condenser, cooling coil, blowers, refrigerant piping system , modification in existing plenum chamber and shall be connected to existing ducting system and will be modified to accommodate the unit. minor repair job shall be done by the firm, if required. , return air chambers at akashvani rampur , switch board and wiring of equipment at akashvani rampur , electrical earthing at akashvani rampur , itc of ac plant includes, dismantling of old ac plants, misc. jobs required for installation of ac plants and provision of indicators for filter clogging and condenser clogging at akashvani rampur , supply of package type air conditioning plant of 16.5 ton capacity at akashvani kanpur. equipment consisting compressor unit, air cooled condenser, cooling coil, blowers, refrigerant piping system , return air chambers at akashvani kanpur , switch board and wiring of equipment at akashvani kanpur , electrical earthing at akashvani kanpur , itc of ac plant includes, dismantling of old ac plants, misc. jobs required for installation of ac plants and provision of indicators for filter clogging and condenser clogging at akashvani kanpur * /bid number : gem/2026/b/7640468 + /dated: 22-06-2026 ' ' / bid document 1 / 24

State Government

CTN :45414122 Due date: 17 Jun, 202617 Jun, 2026 1.90 Crore
Tender For corrigendum : prov installing and drilling of 550 mm dia bore with reverse rotary rig up to 160 mtr. depth including cost of 20 mtr stainless strainer const of pump chamber pumping machinery di fitting rising main ohsr of 250 kl capacity complete in all respect. - augmentation of water supply scheme village padhiana block adampur distt. jalandhar (under head: nabard 31/4215) providing, installing & drilling of 550 mm dia bore with reverse rotary rig up to 160 mtr. depth including cost of 20 mtr stainless strainer, construction of pump chamber of size 3.05m × 3.70m with wc, providing & installing pumping machinery, di fitting, disinfections unit, rising main(10kg/cm2), household connections with water meter and distribution system, solar panel, bulk meter, environmental charges, development of water works, construction of 1 no. ohsr of 250 kl (2,50,000 ltrs) capacity with sill level not less than 23.50m height upto fsl 27.50 m from formation level complete including the cost of inlet, outlet, overflow & scour & vertical pipes, di duck foot bends, expansion joints, puddle collar, lightening conductor, earthing, aluminium ladder inside the ohsr stair case, scour/overflow sluice valves, d/f extension joints, automatic electronic water control device and construction of plinth protection around ohsr, all civil works as per site complete in all respects.

Co-operative

CTN :45474707 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For c.i. item on conversion/supply basis - c.i.pipe with standard thickness & flange as per i.s.i. specification machined from dia 4" to 12"(i) new material supply basis, (ii) on conversion basis, c.i. bend, duck foot bend, cross,tee and other such part all size as per drg.(i) new material supply basis, (ii) on conversion basis, c.i.drum, rod,bush, bari,idler pully, break drum for cane unloader etc as per drg.(i) new material supply basis, (ii) on conversion basis, c.i.coupling from 4"dia to 10"dia plane/flange type(i) new material supply basis, (ii) on conversion basis, c.i. firing frame,door side chamber, bagasse rotary chuts, rotary feeder drum , clit, hanger, beam, gutka, furnace nozzle, clam etc. and other such parts for lipi/taxmaco boiler as per different drg.high chrome grade 25 , casting & machined temp. capacity 15000 c(i) new material supply basis, (ii) on conversion basis, c.i. clamp/ hanger clit small size for lippi boiler no. 3 as per drg. blr-79 high chrome grade 25 , casting & machined temp. capacity 15000 c, c.i scapper mixed with pig iron and having standard hardness dully machined as per drg.no.mh-66 ( r)(i) new material supply basis, (ii) on conversion basis, (iii) grooving of c.i.scrapper as per drg., centrifused casted c.i.coupling for fmg gear of kcp mill od 1000 mm.pcd 815(18 holes)9+9,with machining complete as per drg.no.mh-93, c.i.motor cover for different type motor, mill setting bolt & nut for kcp mill drg.no.mh-106, mill setting bolt & nut for taxmaco mill drg.no.mh-38, c.i.worm and worm wheel for crystilizer as per drg.bh-39 ( r ) machined, c.i.worm and worm wheel for vertical crystilizer no. 2 complete set as per drg. machined, eccentric shaft and eccentric for hopper as per drg.no.bh-60, m.s.shell for under feed roller as per drg.mh-95.length 1525 mm.od 750mm,thickness 18mm, c.i. muff coupling for cane unloader as per drg.no cu-25, c.i.gear for magma mixture as per drg.no bh-137.od 450mm,no.of teeth-51.bore 70mm, width 63mm, c.i.brake drum for s.d.centrifugal machine taxmaco make duly machined(i) as per drg.no. bh 81/1, (ii) as per drg.no bh-81/2, c.i.v-belt pully of cont.centrifugal machine duly machined, c.i.scale seat for juice weighing scale duly machined and drilled as per drg.no.mh-195, id fan pully (as per drawing no. bl-r-128/2024-25), id fan motor pully (as per drawing no. bl-r-129/2024-25), boiler grate bar material-cont iron. (as per sample/drg.), boiler furnace manage gap bar. (ap per sample/drg.), chief engineer

CTN :45408719 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For maintenance of electrical installation and fans including repair maintenance of water pump set diesel generator set in the cpwd colony at bamunimaidan guwahati sh rectification of refrigerant piping and re-charging of vrf system at cpwd office bamunimaidansubwork/packages:rectification of refrigerant

Central Government/Public Sector

CTN :45273514 Due date: 10 Jun, 202610 Jun, 2026 39.50 Lacs
Tender For repair / periodical maint of walk-in-coolers (cold/cool rooms), refrigerant piping, controls and other allied works at bvy and repair / maint / replacement / renewals of split acs, window acs, tower acs, refrigerant piping system, summer cooling appl

Central Government/Public Sector

CTN :45301449 Due date: 13 Jun, 202613 Jun, 2026 41.50 Lacs
Tender For repair / maint / replacement of split acs, window acs, tower acs, summer cooling appliances, refrigerant piping system, controls and other allied works at minniebay area under age e/m-i of ge minniebay

Central Government/Public Sector

CTN :44781244 Due date: 18 Apr, 202618 Apr, 2026 NA
Tender For supply of non-clog sewage submersible pumps (make: ksb pumps limited) along with motor and duck foot bend

CTN :44793624 Due date: 13 Apr, 202613 Apr, 2026 4.19 Lacs
Tender For corrigendum : purchase of leakage materials for arrasting all leakage in yellandu municipality under dmft grant - tbsc-q.vi-11 :fast setting cement based plugging compound , "centrifugally cast (spun) ductile iron fittings conforming to is:9523/2000 having dimensions as per table. the rates mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/is 9523/2000) ( ex-works) excluding transportation and taxes. for double socket branch flange tee, all socket tees, reducers, flanged sockets, flanged spigot, double socket duck foot bend, double flange duck/foot bend, all socket cross, all flange tee, all flange cross, double flange reducer, blank flange, mechanical joints, double socket bends, double flanged bends etc." , "centrifugally cast (spun) ductile iron fittings conforming to is:9523/2000 having dimensions as per table. the rates mentioned here under are for fittings, zinc coated externally with inside mortar lining (with finishing as per class 13/is 9523/2000) ( ex-works) excluding transportation and taxes. for double socket branch flange tee, all socket tees, reducers, flanged sockets, flanged spigot, double socket duck foot bend, double flange duck/foot bend, all socket cross, all flange tee, all flange cross, double flange reducer, blank flange, mechanical joints, double socket bends, double flanged bends etc." , supply and delivery of rubber packing excluding all taxes , supply and delivery of rubber packing excluding all taxes , tbsp-j.iii-58:supply of 32mm ppr elbow conforming to din standards 8077/8086 , "tbsp-j.iii-64:supply of 110mm ppr elbow conforming to din standards 8077/8092" , "tbsp-j.iii-54::supply of 90mm ppr core flange conforming to din standards 8077/8091" , "manufacture, supply and delivery of unplasticised pvcs pipes for potable water supplies conforming to is : 4985/2000 (3rd revision) with bell ends (socket) as per specification in light grey/natural ivory grey/ any other color (except white) inclusive of transportation to the sub-divisional stores anywhere in tg excluding taxes." , 110 mm dia 6.0 kg/sqm , 125 mm dia 6.0 kg/sqm , 160 mm dia 6.0 kg/sqm , 220 mm dia 6.0 kg/sqm , "manufacture, supply, & delivery of hdpe fittings conforming to is 4984 - 1995 including transportation to anywhere in t.g. excluding taxes." , reducers od 110 mm x 125mm , reducers od 200 mm x 225 mm , elec-11.7.5.1:supply, fixing, testing & commissioning of ------ c.i. gate valves os &y as per is:14846 ( pn 10 rating) and rising spindle type with flanges, bolts, nuts,washers, gaskets etc. the valve shall be fitted with chain lock and key arrangement . , elec-11.7.5.1:supply, fixing, testing & commissioning of ------ c.i. gate valves os &y as per is:14846 ( pn 10 rating) and rising spindle type with flanges, bolts, nuts,washers, gaskets etc. the valve shall be fitted with chain lock and key arrangement .