Get complete information related to latest Duct Cover Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Duct Cover Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Duct Cover Tenders.
Tender For supply of air ductcovering plate for hhp actm as per drg no 4/plw/m/tm-sk-127 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For repair/replacement of capacitor bank, sign board, fencing cable ductcover, route indicator and miscellaneous work at various sub station/installation at af stn gwalior.
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
Tender For auction sale of depot non ferrous scrap - lot of scrap non -ferrous items consisting of various type or sizes and short and sizes,diffrent thickness scrap aluminum,aluminium sheet,aluminium roof sheet, cut peices of aluminum, chair parts,aluminum duct,cut peices of coach floor, long aluminium sheet of electrical mechanical ohe and coaching items etc. with or without slightly iron and other attachment.as available in the lot. (p.l. no-98230013)
Tender For auction sale of depot non ferrous scrap - scrap and unserviceable condemned various types of mix aluminium items such as aluminium spares of tl/ac coaches equipment like aluminium casting coupler, alluminium pipes, alluminium tube light parts ,engine magnet defective,door hings,air filter,air compressor parts, air inlet cover, aluminium bare wire ,alluminium ladder ,dv parts,dm plate parts ,duplex valve,door stoppers, aluminium strip sslv body, ,name plate,blower fan blade air ductcover various types of casing , horn, aluminium window frame ,axial fan , fan blade ,plates aluminium safety strap,ivc body,ivc cover, head light glass frame, ocb fan, mvrf fan, mvsi fan, compressor piston ,tension fitting , suspension fitting vibration jumper and other miscellenous aluminium items in broken and dismenetled condition of sort and sizes with or without m.s.,plastic,rubber,cotton wool,glass etc attachment. (qty approx)
Tender For corrigendum : supply of supply of minimum 8 core rack mountable server 32 gb ddr5 ram and 64 bit windows server os 1 tb ssd with required licences for db and application , supply of industrial standard kiosk for mounting the android tablet and flatbed scanner , supply of industrial standard wi-fi enabled android or ios tablet , supply of barcode qr code scanner to scan the qr code in the boarding pass or air ticket , manageable poe switch 24 port , wireless access point , 9u rack rack wall mountable or floor standing with 650va line interactive ups , 4 pair cat6 cable , armoured 6 core ofc cable , installation and configuration of server , installation and configuration of switch and rack , installation of integrated kiosk and tablet and scanner with required accessories , installation and configuration of wap , laying of ofc cable with proper insulation materials like gi pipe or hdpe pipe or rubber ductcovers as per site condition , laying of cat6 cable with proper insulation materials like hdpe pipe or rubber ductcovers as per site condition , installation and configuration of web application , integration of airlines api with server and application for the verifying the passenger details
Tender For supply of aluminum mesh ductcover for first ac corridor area, manufactured from high quality 2mm, aluminium sheet width 540? length 394 mm x 2 mm thickness. designed with 6 mm perforations for properair circulation. suitable for corridor area equipped with 4 oblong corner slots (8 x 15 mm), precisely positioned 12 mm from the length edge and 7 mm from the width edge. the unit is supplied along with 04 machine screws (m6 x 16) and 04 plain washers (m6). (per 09 nos complete set). [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of aluminum mesh ductcover for first ac passenger area, manufactured from high quality 2mm, aluminium sheet width 144? length 293 mm x 2 mm thickness. designed with 6 mm perforations for proper air circulation. suitable for passenger area equipped with 4 oblong corner slots (8 x 15 mm), precisely positioned 12 mm from the length edge and 7 mm from the width edge. the unit is supplied along with 04 machine screws (m6 x 16) and 04 plain washers (m6). (per 09 nos complete set). [ warranty period: 30 months after the date of delivery ] ]
Tender For provision of led light fittings with accessories at various locations in ward no. 167 khanpur, under south zone. - supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3 x 1.5 sq. mm, supply and fixing of 32mm dia x 1 meter long g.i. pipe (medium class) bracket for mounting of fluorescent/hpmv/hpsv street light fitting on pole including bending the pipe to the required shape , 2 nos 25mm x 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:-2c*4 sqmm, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. upto 35 sq. mm, led street light fixture, powder coated pressure die cast aluminum body (system lumen efficacy 135 lm/watt) supplying, installation, testing & commissioning of street light led fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage: 140-270 volt ac, freq 50/60 hz, operating temp range -5 deg centigrade to 50 deg centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-45, driver efficiency >85%,thd 10% as per iec 61000-3-2 , p. f. 0.95, ip66,ik-10, cri 70 , under voltage and over voltage protection,emi-emc as per cispr-15, lenses for beam angle as per iesna type i/ii/iii as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (led,driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till life ends as per lm80 extrapolation ies tm-21-11 report , cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin) , sdcm(standard deviation color matching) 5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 135 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminum housing such that led junction temperature shall not rise above 90 c). 45 watt
Tender For laying pvc xlpe insulated &amp pvc sheathed un armored aluminum cable in existing rcc hume stoneware pvc pipe open duct cable trench cable tray with cable tie including testing etc as required of following size installing various places