Get complete information related to latest Ducting Assembly Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ducting Assembly Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ducting Assembly Tenders.
Tender For supply of electric slaughterhouse (for animals) - primary & secondary chamber primary chamber* single chmber furnace of size 4270 mm x 1980 mm x 1820 mm.* plate thickness- 5 to 8 mm.* lining of interior of furnace- 400 mm wall cermaic blanketk, high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006* operation temperature- 800o c to 1000o c.* top smoke discharge for secondary chamber.* ash removal doors to be provided for ash collection after combustion.* ingtion- automatic.* temperature control- automatic* material loading- front gate- automaticsecondary chamber* operating temperature - 1050o c to 1250o c.* material of construction- mild steel with high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006.* made from is 2062 grade mild steel materials (or better) duty lined with insulation bricks, refractory bricks, hysil boards.* burner mounting arrangement with refractory burner block.furnace door:furnace door charging & discharging side fabricated from 5mm to 6 mm thickness door opening & closing automatic.ash door:* ash door (with casted cement lining) to remove nonhazardous ash from the chamber.* top inlet bottom smoke discharge for longer gas residence time.* furnace door charging & discharging side fabricated from 5mm to 6 mm thickness.* door opening & closing automatic/manual.refractory:{complete set of refractory shaped bricks for construction electric cremation of i.s. 8 bricks (approx. 1007nos bricks,insulation 4000 nos. refractory slid for construction of flue duct , as required, refractory heat resistant fire clay , ceramic blanket hysil board, asbestos ropes etc. as required for outer side of the furnace shall be constructed by red bricks by sand and cement as mortars and construction of chimney from basement of roof level including painting i.e. bricks portion shall be painted by two coats of red oxide as primer and to coats of synthetic enamel. (a) complete lining & assembling of entire cremation chamber according to standard size with proper arrangement of accommodation of heating elements, resting of dead body with sufficient opening for falling of ashes to the ash chamber & sufficient ventilation for fresh air spraying. (b) complete lining and assembling of entire cremation chamber according to standard size with provision of drawing out aces from the rear side and sufficient ventilation for fresh air injection. complete lining and assembling of entire cremation chamber according to the standard size with provision of air inlet supplying by fresh air blower and arrangement of multi ventilation path for fresh air}. osspl make, thermocouple heat sensor supply & fixing the thermocouple of heat sensing range 0 - 1200 c (cr.-al) sensor housed in s.s 304 casing of dimension 1200 mm long 22 mm od complete encased to and fitted terminal on other and for connection of compensating of 2 cores 0.5 aq. mm cr- al for heat sensing from thermocouple to temperature controller covered with asbestos embedded rope about 50 m length as per direction of eic., f.d. fan/centrifugal air blower with electric motor * supply and delivery at site, installation, testing and commissioing.* of fresh air injection system forced draft fan mild steel.* type: centrifugal.* capacity:- 500 cmh.* pressure:- 220 mmwg.* motor rating:- 2hp (kirloskar/crompton), burner assembly * total 2 nos. of lpg/cng/png fired automatic burner required.* the burner should be provided with comprising diffuser plate/ burner plate, photo cell housing electrodes with holding brackets, solenoid valve, electrodes caps, flexible hose pipes, spary nozzles, oil filter, blower, etc. connected with electric motor (each burner) & in built air regulator.* burners will work on auto on/off as per the set temperature for the combustion chambers.* the in-built bolwer will provide continuous air flow to the burners to prevent demages due to high temperature., supply and fixing of manifold with a p
Tender For supply of st010040242 belt cover guard for fbhe ash cooler blower, model-rkr k-150 , st010040264 - oil drain valve of sealpot blower , st010040265 - oil drain valve of fbhe blower , st010040276 - oil drain valve of p and s blower , sc500140244 - air blower filter mat , sc500140245 - air blower filter mat of size 1550 x 510 x 20 minimum , sc500140246 - air blower filter mat of size 900 x 510 x 20 minimum , st010040273 - multi layer suction bag filter assembly for sealpot blower , st010040272 - discharge valve for sealpot blower, dn200, k-35 , st010040268 - discharge valve for p and s blower, dn250, k-90 , sc110480149 - motor pulley for bed ash conveying blower , sc110480150 - blower pulley for bed ash conveying blower , st010040240 - belt cover guard for p and s blower, model-rkr k-90 , st010040239 - belt cover guard for sealpot blower, model-rkr k-35 , st010040275 - suction filter mesh for blowers common suction duct, 1500mm x 5000mm, ss wire mesh hole size 5x5mm2 , st010030077 - suction filter element, 24 inch x 24 inch x 2 inch, for bed ash conveying blower , st010030078 - suction filter element, 24 inch x 24 inch x 12 inch, for bed ash conveying blower ) /bid number : gem/2025/b/6728501 * /dated: 27-09-2025 & & / bid document 1 / 18
Tender For supply of hand brake cable , v belt 12.5 x 900 , assy air pressure pipe , hose assembly air duct , element oil filter , gear lever kit n m , major repair kit air compressor , brush carrier assy , brake shoe linning set 7 , rear door glass , repair kit for slave cylinder
Tender For supply of c-dac cute traffic controller , traffic controller cabinet , 300mm red led aspect 24 v dc with inbuilt voltage current regulator 400 ma max. including dust and water proof polycarbonate housing and clamps , 300mm amber led aspect 24v dc with inbuilt voltage current regulator 400ma max. including dust and water proof polycarbonate housing and clamps , 300mm green arrow led aspect 24v dc with inbuilt voltage current regulator 200 ma max. including dust and water proof polycarbonate housing and clamps , 219mm dia 12 meter long steel tubular poles swaged type conforming to is 2713 including bend pipeas per fig number 2 suitable for mounting on rcc foundation , dust and water proof polycarbonate housing and clamps for signal lamps , junction box for poles with suitable clamps and connectors for signal lamp termination as per fig number 7 , 14 core 1.5sqmm pvc insulated armoured copper cable for signal data , control cable 6 core 0.5sqmm pvc insulated un armoured copper cable from junction box to signal lamps , 3 core 2.5sqmm pvc insulated armoured copper cable for power supply , cat-6 unarmoured cable , 150 mm gi pipe , 100 mm hdpe pipe , powder coated sheet metal fabricated battery box with locking facility using pad lock , 2 kva ups including cabinet with 6hr backup , 25mm dia pvc gland for cable entry for lamp assembly , 25mm dia pvc conduit for wiring , powder coated ms pole cap with cdac logo screen print , construction of plinth of brick pcc foundation with cement plastering and ms frame , construction of rcc plinth suitable for erection of standard pole with 10m vertical height , erection of standard pole on rcc foundation , mounting and wiring of junction boxas per fig number 6 , laying of cables in bunch through hdpe duct inside gi pipe , construction of plinth of brick pcc foundation with cement plastering for mounting battery cabinet , mounting and wiring of line charger inside battery cabinet , commissioning of traffic controller earthing , commissioning of pole earthing , construction of earth pit , excavation works width 500mm and depth 2000mm for laying 100mm x 2 hdpe pipe inside 150mm gi pipe on carriageway refilling and restoring the surface to original condition , construction of cable pull chamber with cover , construction of traffic controller box chamber for maintenance purpose , any other items and services required for successful commissioning of the traffic signal system sub-project as per the scope of work should be added as individual line item //bid details 2 / 30