Get complete information related to latest Ducting System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ducting System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ducting System Tenders.
Tender For bid to ras corrigendum : procurement of air conditioning system for ntpc singrauli project - supply- ac and ventilation system -air cooled condensing unit , supply- ac and ventilation system -air handling unit -ahu , supply- ac and ventilation system -strip heaters , supply- ac and ventilation system -pan humidifier , supply- ac and ventilation system -copper refrigerant piping -suction line , supply- ac and ventilation system -copper refrigerant piping -liquid line , supply- ac and ventilation system -refrigerant gas , supply- ac and ventilation system -gss duct sheet - 24 g - air conditioning system , supply- ac and ventilation system -gss duct sheet - 22 g - air conditioning system , supply- ac and ventilation system -gss duct sheet - 20 g - air conditioning system , supplyac and ventilation system -gss duct sheet - 18 g - air conditioning system , supply- ac and ventilation system -volume control damper , supply- ac and ventilation system -fire damper , supply- ac and ventilation system -motorised actuator for fire damper , supply- ac and ventilation system -grills diffusers , supply- ac and ventilation system - accoustic insulation , supply- ac and ventilation system -thermal insulation , supply- ac and ventilation system -fine filter , supply- ac and ventilation system -dp switch , supply- ac and ventilation system -fresh air fan assembly , supplyac and ventilation system -cassette ac unit - 4 tr , supply- ac and ventilation system -cassette ac unit - 3 tr , supply- ac and ventilation system -cassette ac unit - 2 tr , spares- ac and ventilation system -v belts for blower , spares- ac and ventilation system -ahu blower bearings of each type , sparesac and ventilation system -blower motor bearing , spares- ac and ventilation system -pre filter for ahu , spares- ac and ventilation system -fine filter for ahu , spares- ac and ventilation system - electrical actuator , spares- ac and ventilation system -dp switch , spares- ac and ventilation system -relative humidity sensors , spares- ac and ventilation system -geyserstat , spares- ac and ventilation system -local humidity temperature indicators , etc- ac and ventilation system -air cooled condensing unit , etc- ac and ventilation system -air handling unit -ahu , etc- ac and ventilation system -strip heaters , etc- ac and ventilation system -pan humidifier , etc- ac and ventilation system -copper refrigerant pipingsuction line , etc- ac and ventilation system - copper refrigerant piping-liquid line , etc- ac and ventilation system -refrigerant gas , etc- ac and ventilation system -gss duct sheet - 24 g - air conditioning system , etc- ac and ventilation system -gss duct sheet - 22 g - air conditioning system , etc- ac and ventilation system -gss duct sheet - 20 g - air conditioning system , etc- ac and ventilation system -gss duct sheet - 18 g - air conditioning system , etc- ac and ventilation system -volume control damper , etc- ac and ventilation system -fire damper , etc- ac and ventilation system -motorised actuator for fire damper , etc- ac and ventilation system -grills diffusers , etc- ac and ventilation system - accoustic insulation , etc- ac and ventilation system -thermal insulation , etc- ac and ventilation system -fine filter , etc- ac and ventilation system - dp switch , etc- ac and ventilation system -fresh air fan assembly , etc- ac and ventilation system - cassette ac unit - 4 tr , etc- ac and ventilation system -cassette ac unit - 3 tr , etc- ac and ventilation system -cassette ac unit - 2 tr , etc- ac and ventilation system -cable laying
Tender For corrigendum : supply of wire nails (q4) , cat - 6 utp ethernet cable for wifi indoor use (mtnl) (q3) , wooden beading patti (q4) , radio frequency co - axial cable type 75 - 7 - 2 (coaxial cable) as per is 5802 (q3) , electrical connection lugs or thimbles (q3) , connector mounting hardware - multi plug (q3) , cable trunking and ductingsystem for electrical installations (wiring duct) (q3) , rigid plain conduits of insulating materials as per is 9537 (part 3) (q3) , emergency push button switch (q3) , pvc gitti (q3) , buzzer switch. (q3) , light emitting diode driver (q4) , elecric bells and accessories as per is 2268 (q3) , cable nail clip (q3)
Tender For hot air gate assembly for mill hot air duct with pneumatic power cylinder and bulb seal assembly pneumatic operated single power cylinder guilotine horizontal type ensuring 100 sealing with hastelloy material seals including electrical accessories
Tender For hot air gate assembly for mill hot air duct with pneumatic power cylinder and bulb seal assembly pneumatic operated single power cylinder guilotine horizontal type ensuring 100 sealing with hastelloy material seals including electrical accessories
Tender For name of worknctps ii - m-i circle bm unit-ii aoh 2025-26 replacement of the severely eroded and damaged a1, a2, b1 & b2 stream splitter assembly in flue gas duct at esp inlet
Tender For supply of h.b.f spares> - wear belt (56850 x 50 x 6mm thk), scrapper blades 4.2mtrs hbf, curb of 125mm height (each meter), 4 numbers of end slides, buta seal (1mm thk x 29000mm), teflon strips (4200mm lg) (uhmwpe), spray nozzles (each), belt guide rollers, cloth trackig air bellows (1 set = 2 nos), plummer blocks for 110 sq.mm "uhmwpe"-1210ek with out bearing, plummer blocks "uhmwpe"-1209ek with out bearing, vacuum box lifting cylinder assembly, 4 nos ss304 clamps, air duct sleeve, 400 nb belt return rollers "msrl", feed dam roller msrl, 100 nb cloth return rollers, 150 nb cloth return rollers, cloth tension assembly, pneumatic panel, filtration hose along with 100mm x 2900mm length with 4nos ss304 clamps, filtration hose along with 100mm x 3000mm length with 4nos ss304 clamps, one set of seal strips s for 110 m2 hbf (one set consists of 18 pieces for the vaccum box, 1 piece at head end, 1 piece tai end, 4 pieces half moon at ends), slurry feeder hose for nuetral hbf flexible hose -274m id x 1850mm long with hose clamps to suite 250b pipe., slurry feeder hose for nuetral hbf flexible hose -169m id x 1800mm long with hose clamps to suite 150b pipe., bowed roller for horizontal belt filter of diameter 150mm (moc of shaft : ss316), axle diameter : 75mm.roller face : 4450mm, height of bow : 74mm, wear belt(56850 x 50 x9 mm thk), vacuum box (moc :ss304), vacuum box lifting leaver assembly(moc :ss304), spares of 5 m2 horizontal vaccum belt filter (model: 12b/02-30v product filter), cloth tensioner assembly, belt return rollers 250 nb, feed dam rollers 285 nb, cloth roller 75 dia, cloth tension roller 75 dia, cloth tracking roller 75 dia, belt guide roller m.k a ss304/hdpe, belt guide roller m.k b ss304/hdpe, belt guide roller m.k c ss304/hdpe, seal water assy-ss304, spray pipe assembly, spray sheet pvc, cloth tracking unit-ss304/nr bellows, pneumatic pannel/cloth sensor assy, spray pipe manifold, slurry feeder assy, curb 75mtrs ht (each meter), wear belts endless (6thk x 35 width, 12875 length), plummer blocks "uhmwpe"-1207ek with out bearing, cloth scrapper, plummer blocks 30 dia for scrapper "uhmwpe" with out bearing, feed dam roller bearing blocks with out bearing, filtrate hoses along with hose id 75 x 1750mm long with 4 nos of ss316 clamps, seal strip sets consistes of 4 nos of seal strip, 1 no. head end pad, 1 no. tail end pad, and 4 nos of end slides
Tender For supply of pvc flat cable, aluminium conductor with pvc insulation and sheath as per is 694 (q3) , cable trunking and ductingsystem for electrical installations (wiring duct) (q3) , mcb - miniature circuit - breakers for a.c. operation as per is / iec 60898 (part 1) (q2) , modular electrical enclosure switch board boxes for modular type accessories (q3) , rigid plain conduits of insulating materials as per is 9537 (part 3) (q3) , led batten (q2) , call bell (q3) , switch fuse unit (q3) , propeller type ac ventilating fans - exhaust fans (v2) as per is 2312 (q2) , wire nails (q4) , modular piano type domestic electrical switches as per is 3854 (q3) , piano type modular domestic electrical sockets - is 1293 (q3) , piano type non modular electrical switch socket combination as per is 3854 and is 1293 (q3) , non - modular piano type domestic electrical switches as per is 3854 (q3) , piano type modular domestic fan regulator as per is 11037 (q3)