Web Analytics Made Easy - StatCounter

Duplicating Machine Scrap Tenders

Get complete information related to latest Duplicating Machine Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Duplicating Machine Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Duplicating Machine Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :44230745 Due date: 10 Jun, 202610 Jun, 2026 5.89 Crore
Tender For corrigendum : tender for supply and installation of blood storage equipment for blood storage centres under ksaps programme - blood centre refrigerator, donour couch, automated hematology analyzer 3 parts, automated elisa reader and washer., apheresis for sdp and plasma apheresis, weighing balance (electronic) to weigh blood bags, test tube centrifuge, temperature regulator ice box (4 each), sterile blood connecting device, temperature data logger, reagent refrigerator 2 to 6 degree, plasma thawing bath, plasma expresser manual (4 each), microscope, binocular microscope with inbuilt light, laminar air flow., hemogloin analyzer, hand sealer cutter-portable (2 each), dry bath, dielectric tube sealer (bench model) (2 each), cryo bath, blood collection monitor, refrigerated centrifuge (heavy duty handle 12/16 bags), gel card centrifuge and incubator, platelet agitator and incubator, deep freezer (-80), deep freezer(-40), blood centre refrigerator, donour couch, automated hematology analyzer 3 parts, automated elisa reader and washer., apheresis for sdp and plasma apheresis, weighing balance (electronic) to weigh blood bags, test tube centrifuge, temperature regulator ice box (4 each), sterile blood connecting device, temperature data logger, reagent refrigerator 2 to 6 degree, plasma thawing bath, plasma expresser manual (4 each), microscope, binocular microscope with inbuilt light, laminar air flow., hemogloin analyzer, hand sealer cutter-portable (2 each), dry bath, dielectric tube sealer (bench model) (2 each), cryo bath, blood collection monitor, refrigerated centrifuge (heavy duty handle 12/16 bags), gel card centrifuge and incubator, platelet agitator and incubator, deep freezer (-80), deep freezer(-40), blood centre refrigerator, donour couch, automated hematology analyzer 3 parts, automated elisa reader and washer., apheresis for sdp and plasma apheresis, weighing balance (electronic) to weigh blood bags, test tube centrifuge, temperature regulator ice box (4 each), sterile blood connecting device, temperature data logger, reagent refrigerator 2 to 6 degree, plasma thawing bath, plasma expresser manual (4 each), microscope, binocular microscope with inbuilt light, laminar air flow., hemogloin analyzer, hand sealer cutter-portable (2 each), dry bath, dielectric tube sealer (bench model) (2 each), cryo bath, blood collection monitor, refrigerated centrifuge (heavy duty handle 12/16 bags), gel card centrifuge and incubator, platelet agitator and incubator, deep freezer (-80), deep freezer(-40), blood centre refrigerator, blood centre refrigerator, donour couch, donour couch, automated hematology analyzer 3 parts, automated hematology analyzer 3 parts, automated elisa reader and washer., apheresis for sdp and plasma apheresis, automated elisa reader and washer., weighing balance (electronic) to weigh blood bags, apheresis for sdp and plasma apheresis, test tube centrifuge, temperature regulator ice box (4 each), weighing balance (electronic) to weigh blood bags, sterile blood connecting device, test tube centrifuge, temperature data logger, temperature regulator ice box (4 each), sterile blood connecting device, reagent refrigerator 2 to 6 degree, plasma thawing bath, temperature data logger, reagent refrigerator 2 to 6 degree, plasma expresser manual (4 each), plasma thawing bath, microscope, binocular microscope with inbuilt light, plasma expresser manual (4 each), laminar air flow., microscope, binocular microscope with inbuilt light, hemogloin analyzer, laminar air flow., hand sealer cutter-portable (2 each), hemogloin analyzer, dry bath, hand sealer cutter-portable (2 each), dielectric tube sealer (bench model) (2 each), dry bath, cryo bath, dielectric tube sealer (bench model) (2 each), blood collection monitor, cryo bath, refrigerated centrifuge (heavy duty handle 12/16 bags), gel card centrifuge and incubator, blood collection monitor, refrigerated centrifuge (heavy duty handle 12/16 bags), platelet agitator and incuba

CTN :45314456 Due date: 05 Jun, 202605 Jun, 2026 NA
Tender For supply and installation of bera system - supply & installa tion of bera system, software and accessories -(specification mentioned as in the notice inviting tender document), specifications ecochg cortical aep (p100, llr, p300, mmn) am lr, eabr vestibular evoke d myogenic potenti al (vemp) algo rithm for emg rec tification assr, stacked abr (if p ossible). transducers - ins ert earphone s -td h headphone -bon e vibra tor - loudsp eaker stimulus - click (user-selecta ble from choi ces of 50, 100, 150, and 200 use) tone bur st (frequenci es 2 50 to 8 khz, choice of linear, henning, blackman or gaussian stimulus ramps for tone burst). t one pip speech: /p a/, /ta/, / ka/ ce- chirp, ce-chirp o cta ve bands mas king noise: pink a nd white noise p olarity: alternating , condensation, rar efaction intensity: 0 to 130 db spl or more repetition rates: 0.2 100 depending on modality data points: 256, 512, 1024 or more test protocols - unlimited, the system must support th e creation of user-d efined custom protocols capable of calculating a numeric correlation of t wo selected wavef orms to define simi larity between the collected waveforms objectively. c apable of performi ng weighted and unweighted addition and subtraction of selected waveforms. capable of sep arating abrdata c ollected with altern ating polarity stimu lation into its separate rarefaction and condensationwave form components. system must sup port automatic elec trode switching for singlechannel data collection such thatmanual movement of electrodesin the electrode cable is n ot required to colle ct ipsilateral data when changing the stimulus ear. syst em must be capabl e of applying user- specified post hoc digital filters durin g data analysis. s ystem must suppor t simultaneous revi ew of data frommultiple test sessions for the patient in th e same on-screen d isplay and report to facilitate monitorin g for changes over time. system mustprovide a means o f password-protecti ng thetransducer c alibration values to prevent inadvertent editing by unautho rised personnel. t he system should h ave an option for external direct printi ng of the report data export to hl7 protocols along wit h the facility to pro vide free api the system should have compliance with international regula tory standards of c e,fda, and iso. free period cali bration for the first three years and afte r three years of cal ibration along with amc support for5 years to be provid ed at the national i nstitute of speech a nd hearing com puter supplied alon g with the equipme nt needed to meet t he below requirem ents latest wind ows operating syst em processor whi ch is intel i 7 or hig her with clock spee d > 2.5mhz ram>= 8 gb and stora ge space ssd>= 5 00gb minimum 3 usb portsalong with 1 hdmi, 1eth ernet port warrant y of the computer b e three years mini mum equipmen t should be powere d using 240v 5ohz. the connection s hould be type d the software sup plied along with th e hardware should have the provision for free upgradation if a new version l aunches in the mar ket within the next five ye ars of the ins tallation also provide free software up dation and support as operating syste m upgradation hap pens penalty for thedelay in repair and delivery of the equipment and acc essories. the penal ty amount is calcul ated based on 24 h ours / 48 hours, an d 72 hours and if t he supplierdoes no t deliver the produc t within ten days of issuing the purchas e order, they should be blacklisted., cmc/amc cost a fter the completion of 3 years of warranty period ( 7 yearsof amc)

Central Government/Public Sector

CTN :45209964 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For supply installation, testing & commissioning of gps based ohe monitoring & current collection system oliver-g. as per rdso spec no is/rdso-ti/0001:2023 or latest along with all accessories/authentic software as per mentioned specification necessary for mapping with additional power back up. (1) whileproviding complete set of oliver g plus, data loading with one round of testing with consignee person in included with the above item. (2) as per rdso specification supply of laptop with core i 7 with minimum 8 gb ram, 512 ssd hdd, gps for location tracing, and magnet based mounting system. (3) for route mapping provision of the equipment and man power, the location report will be shared to consignee in csv format also loading the new rout data to oliver g system. (4) additional license data logging software will also be provided with above item(5) with magnetic mounting of camera. (6) above the all these specifications the system should capable to detect spark in day time (sun light). [ warranty period: 30 months after the dateof delivery ] ]

CTN :45138402 Due date: 26 May, 202626 May, 2026 1.99 Crore
Tender For corrigendum : supply of ir & visible spectrum data collection equipment

CTN :44963673 Due date: 05 May, 202605 May, 2026 1.54 Crore
Tender For supply, installation, commissioning, testing, training and maintenance of instrumentation of taraka dam in mysore district of karnataka state under drip-ii (package-3) - world bank aided. - automatic water level recorder, weather station, uplift pressure measurement system, jelly filled cable, cable termination and switch box, spvc cable, laying of armoured jelly filled cable, providing and installing of digital readout unit, providing and installing of data collection unit and transmission system server, settlement plate/survey markers, data collection unit and transmission equipment, providing and installing of electronic sirens, providing installation and commissioning of tilt meters, vibrating wire piezometer/pore pressure meter, drilling of 1 mts bore holes, pair armored jelly filled cable of standard, cable termination and switch box-2, laying of armoured jelly filled cable-2, pvc pipe, v noutch, slope stability analysis, masw test to estimate dynamic soil constant, installation charges, installation charges for drainage gallery instrumentation, total station, amc
 Loading, Please wait...

Connect us via What's Up