Get complete information related to latest E Governance Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic E Governance Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding E Governance Tenders.
Tender For corrigendum : tender for supply of system description general requirements including cyber security technical requirements full hd fixed box type ip colour camera with varifocal lens and housing & mount 4k uhd fixed box type ip colour camera (type a/type b) with varifocal lens and housing & mount full hd bullet type ip colour camera 4k uhd bullet type ip colour camera (type a/type b) full hd fixed dome type ip colour camera full hd ptz (pan, tilt, zoom) ip colour camera digital keyboard large format display monitor server/workstation hardware network video recorder (nvr) pc workstation external storage device core switch (1). aggregation switch (ii). layer 2 switch (24 port) a. poe b. non-poe (iii) field switch a. b port b. 4 port wireless transmitter/receiver unit copper to fiber media convertor various types of cables software requirement video management software graphical user interface client software video recording software artificial intelligence (al) enabled video analytics software remote viewing on web and mobile app functional requirement of command control centre (ccc) software face recognition software software license test requirements test procedure quality assurance making and packing information to be supplied by the purchaser training documentation schematic diagram- 1: schematic diagram of ip based video surveillance system at stations schematic diagram 2: schematic diagram for video surveillance system for cluster of stations schematic diagram- 3: schematic diagram for cloud based architecture of video surveillance system for cluster of stations
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cableentry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protectiveenclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For notice inviting tender for concession to supply, install, test, commission (sitc) and operate vehicle parking management system, collection of parking fees and lane pick up fees rights
Tender For corrigendum : selection of suitable backend partner for exclusive pre-bid teaming arrangement for development of 83 digital application modules under the comprehensive digital governance platform along with resource deployment component and to integrate it with existing erp of higher education department-odisha
Tender For a.r. & maintenance of 196 hmps flats at south avenue under sub div-1 of ded-201, new delhi. (sh: replacement of defectiveelectrical accessories i/c supply of material).subwork/packages:replacement of defectiveelectrical accessories i/c supply of material. - supplying, installation, testing & commissioning of flood light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with driver efficiency >85%, input voltage : input voltage: 140-270 volt ac, freq 50/60 hz, operating temp range - 5 deg. to 50 deg. centigrade, internal surge protection of 5 kv l,n,e as per iec 61000-4-5, driver efficiency >85%, thd < 10% as per iec 61000-3-2, p. f.≥0.95, ip-66, ik-10, cri >70, under voltage and over voltage protection, emiemc as per cispr -15, lenses for beam angle 30 deg- 120 deg as per the application and the project requirement deg., suitable tilt able fitting, life time (led, driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial lumen maintained till lifeends as per lm80 extrapolation ies tm-21-11 report, cct 3000°k/4000°k /5700°k /6500°k (as per ansi bin), sdcm(standard deviation color matching) <5, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 105 <120 lm/watt output. lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted.. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90°c). (make: havells/ wipro/ philips/ crompton/ regent) 1.1 50 watt , 1.5 sq mm frls pvc insulated single core copper conductor cable., , 4 sq mm frls pvc insulated single core copper conductor cable., , 6 sq mm frls pvc insulated single core copper conductor cable., , s.p. 5/6 a, one way modular switch, , s.p. 5/6 a, two way modular switch, , s.p. 15/16 a, one way modular switch, , 3 pin 5/6 a modular socket outlet, , 6 pin 15/16 a modular socket outlet, , modular bell push, , stepped type modular fan regulator (2 module), , telephone socket outlet modular type, , t.v. socket outlet modular type, , modular blanking plate, , modular base & cover plate for 1 or 2 module, , modular base & cover plate for 3 module, modular base & cover plate for 4 module, , modular base & cover plate for 6 module, , modular base & cover plate for 8 module, , modular base & cover plate for 12 module, , modular gi box for 2 module, , modular gi box for 3 module, , modular gi box for 4 module, , modular gi box for 6 module, , modular gi box for 8 module, , modular gi box for 12 module, , 3 pole mccb, 125 a, 16ka, , 6 amps. to 32 amps. ratings, sp mcb, "c" curve, 10 ka breaking capacity, , 40 amps., 2 pole isolator, , 63 amps., 2 pole isolator, , 100amp., 4 pole isolator, , supply of led batten light (system lumen efficacy ≥105 <120 lm/watt) of following body materials. powder coated die cast /extruded aluminium body (thickness > 1.20 mm) (make: havells/ wipro/ philips/crompton/regent), , 18-22 watt, , 40 watt, , supply of led down lighter (smd type) (system lumen efficacy ≥ 105 <120 lm/watt) of following body materials. powder coated die cast/extruded aluminium body including trim with aluminium reflector (make: havells/ wipro/ philips/ crompton/regent), , 5-7 watt, , 8-10 watt, , 12-15 watt, , supply of led bulb 9 watt b-22/e- 27 type (3 star & above) (white/yellow colour) (make: havells/ wipro/ philips/ crompton/regent), , less credit for damaged and dismantled material received from the work :-, , 5/15/16 amp. switch/socket/bell push/tv antenna socket/telephone socket/dp switch/fan regulator (assorted), , pvc
Tender For corrigendum : concession to supply, install, test, commission (sitc) and operate automated vehicle parking management system, collection of parking fees and lane pickup fees rights at maharishi valmiki international airport, ayodhya - concession to supply, install, test, commission (sitc) and operate automated vehicle parking management system; collection of parking fees and lane pick-up fees rights at maharishi valmiki international airport, ayodhya
Tender For corrigendum : notice inviting tender license for concession to supply install test, commission and operate vehicle parking management system collection of parking fees at pantnagar airport, pantnagar - notice inviting tender license for concession to supply, install, test, commission and operate vehicle parking management system collection of parking fees at pantnagar airport pantnagar
Tender For corrigendum : concession to supply, install, test, commission (sitc) and operate automated vehicle parking management system, collection of parking fees and lane pickup fees rights (short term) at maharishi valmiki international airport, ayodhya
Tender For corrigendum : providing of hiring of consultants - milestone/deliverable based - management consultants, functional consultants, subject matter experts, engagement of consultant for documentation, governance framework and autonomy application support; as per project requiremen..