Get complete information related to latest Earth Spike Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earth Spike Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earth Spike Tenders.
Tender For repairing, testing servicing and of national resistors make 11 kv, 10 amp restricted neutral grounding system sl no. 1434, for tr-4, 33/11 kv at ramkanali substation, katras area
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For rate contract supply of material for annual maintenance of streetlight for the year 2026 27 - supply of :, 45 watt led luminary energy saving & enviromentally friendly long life led street light almunium die-cast housing (ip 66 protection sun-beam seno) certified by bis,roh,ce with two years warrenty after date of commissioning, 70 watt led luminary energy saving & enviromentally friendly long life led street light almunium die-cast housing (ip 66 protection sun-beam seno) certified by bis,roh,ce with two years warrenty after date of commissioning, 3/4"" pvc pipe for service line fixing on pole with ties belt, 200 watt led flood light/luminaries ip 66 with bis, roh ce & company scaner bar-code, 150 wattled flood light ip 66 with bis, roh ce & company scaner bar-code, 110 watt led light ip 66 cerified with bis, roh ce & company scaner bar-code, 130 watt led light /luminaries ip 66 with bis, roh ce & company scaner bar-code, 90 watt led lights / luminaries flood light ip 66 with bis, roh ce & company scaner bar-code, led drivers for 200 watt led lights, led driver 130 watt led light of standar make pasted with company scaner code, led driver for 120 watt led lights pasted with company scaner code, led driver 110 watt led light pasted with company scaner code, led driver for 80 watt led light pasted with company scaner code, 19 mm dia pvc /hdpe conduit, 25 mm dia triple lyer hdpe conduit, 50 mm dia triple lyer hdpe conduit, 70 mm sq tripl layer hdpe conduit, 1.5 mm sq copper wire, 2.5 mm sq copper wire, 4 mm sq copper wire, 6 mm sq copper wire, 2 amper single pole mcb, 6-10 ampere single pole mcb with box, 16 ampere double pole mcb, 25 ampere mcb 04 pole, 32 ampere single pole, 32 amper double, 32 ampere tpn 04 pole mcb, 40 ampere tpn 04 pole mcb, 63 amper 4 pole mcb, 100 ampere mccb of standar make, led bulb 09/11watt of standard make certified isi make, led bulb 50/45 watt of standard isi certified make, time delay relay for servo stabilizer, astrnomical timer of standard make, 50 hz contractor of standard make, distilled water, ms nuts, bolts , washers of sizes, 11 kva cable joint kit, 11 kva cable termination kit, 10-95 sq mm al, thimbles, cable jointing thimble 10-95 sq mm, 6 sq mm 02 coreal, cable standard make, 10 sq mm 02 core al cable, 16 sq mm 02 core cable, 25 sq 02 core al cable, 6 sq mm 04 core al xlpe cable of standar make, 10 sq mm 04 core al xlpe cable, 16 sq m 3.5 core xlpe cable, 25 sq 3.5 core xlpe cable, 35 sq mm 3.5 core cable, pvc tape roll, 8" inche taparia plair, star type screw driver big size, star type screw driver medium size, high beam torch light, tool box, 100 amper bus-bar 1 18 to 24 copper, 100 amper bus-bar 1 18 to 24 aluminum, 08 way termination blocks / connector, 150 watt led driver 700 amper constant current philpps, havells, fulham certified with bis, roh , ce with company bar-code scanner, 130watt led ornamental hanging type luminary housing (dgl-103-m) d fitted with 130 watt led panel for 9mtr longt iron/ms composite pole., batton type brass holder, pendent holder, ms junction box complete with fixed clamps nuts and bolts, abs transpernt junction boxs, time-delay rellay, repairs of 10kva to 25 kva avr, transformer oil, m.s boss fitted for 100 ampere mccb complete, earthing spike- rod 2 mtr long, 08 no.g.i wire, 80 to 120 sq mm al, thimble, 11 kv link-set, 11 kv drop-out set, 11 kv surge lighting arrestor, extension cords heavy duty, 250x500 mm pcd g.i door plate for 9/7 mtr long octogonal pole, supply of ornamental cast iron lighting posts along with double sided ornamental bracket with an overall height of 5.0 mtrs long., cast -aluminum ornamental luminaries along with 50 watt led bulb (crompton/philips/panasonic/bajaj/havellls/hpl) compatiable with the cast iron ornamaental cast iron cross arms for 5mtr long cast iron ornamental lighting posts (complte job), canopy type double door dust & corossion free lt feeder panel 3x4x16" fabricated out of sheet steel
Tender For supply of digital earth tester with hard carrying case, 3 pole & 2 pole earth resistance measurement (.01-2000 ohm), ip 67, earth voltage measurement (ac/dc 0-300 v), measuring range 0-200 ohm, accurancy +/- 1.5% rdg +/- 4dgt, earth voltage (0-300v ac/45-65 hz, 0-300 v ac) 1 set of test leads & auxilliary earthspikes similar to kyoritsu, japan model no. 4105dl-h accuracy +/-% rdg standard iec 61010-1, cat iv 100v/ cat ii 300 v/cat iii 150v, pollution degree 3, iec 61010-031, iec61010-031, iec 61010-2-30as per drawing/spec. iec 51557-1, iec 61557-1, iec 60529, iec61326-1, en50581 (rohs) make kyoritsu model equ. o kew 4105dl-h, fluke, meggar, scientific or similar brand note- at the time of delivery, the firm should submit the necessary test certificate issued by a government-approved agency along with the material. [ warranty period: 30 months after the date of delivery ]
Tender For supply of digital earth tester with hard carrying case, 3 pole & 2 pole earth resistance measurement (.01-2000 ohm), ip 67, earth voltage measurement (ac/dc 0-300 v), measuring range 0-200 ohm, accurancy +/- 1.5% rdg +/- 4dgt, earth voltage (0-300v ac/45-65 hz, 0-300 v ac) 1 set of test leads & auxilliary earthspikes similar to kyoritsu, japan model no. 4105dl-h accuracy +/-% rdg standard iec 61010-1, cat iv 100v/ cat ii 300 v/cat iii 150v, pollution degree 3, iec 61010-031, iec61010-031, iec 61010-2-30as per drawing/spec. iec 51557-1, iec 61557-1, iec 60529, iec61326-1, en50581 (rohs) make kyoritsu model equ. o kew 4105dl-h, fluke, meggar, scientific or similar brandnote- at the time of delivery, the firm should submit the necessary test certificate issued by a government-approved agency along with the material.