Get complete information related to latest Earth Bar Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earth Bar Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earth Bar Tenders.
Tender For renovation work of electrical installation in admin block, workshop and washing plant at dtc seemapuri depot. - wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required., wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required., group c, wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required., wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required., wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required., 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, 2 x 6 sq. mm + 1 x 6 sq. mm earth wire, 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/recessed steel/ pvc conduit as required., 5 x 4 sq. mm, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required., 32 mm, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required., 5/6 a switch, 15/16 a switch, 3 pin 5/6 a socket outlet, 6 pin 15/16 a socket outlet, supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required., 3 module (100 mmx75 mm), 6 module (200 mmx75 mm), 8 module (125 mmx125 mm), 12 module (200 mmx150 mm), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 a & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required., supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box/ wooden block including connections etc. as required., wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required., group c, providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required., 150 a, 16 ka,tpmccb, 100 a, 30ka, fpmccb, supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator), 12 way, double door, supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copp
Tender For supply, erection, testing & commissioning of lt panel consisting of 400a 50ka 4 pole microprocessor based mccb - 02 nos as incoming , 200a/250a 36ka 4 pole microprocessor based mccb-03 nos, 63a 36ka 4 pole microprocessor based mccb-02 nos and 63a 10ka dp 2pp mcb - 02nos as outgoing, all mccbs shall be with rotary switch, with voltmeter,ammeter, led indicator lamp,cu. bus bar , neutral link, earthbar, spreader link, lock and key feature arrangement cable gland etc. with suitable sheet steel enclosure conforming to cege/grc's specification no. ser/elec/gs/description/ltpanel/1/rev-0/mar2024 or latest.minimum size of panel 1800 mm (h)x 2400mm (l) x 600 mm(d). [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of electrical materials for the repair and maintenance of street light as per the boq - details, t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder (porcelain), led driver 50w bis certified, led mcpcb plate 60w, led mcpcb plate 50w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earthbar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earthbar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolytic corrosion,excellent water resistance,suitable for primary ins