Get complete information related to latest Earth Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earth Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earth Relay Tenders.
Tender For supply of 093600255 micro-processorbased relay micom p111 or easterly, model l, ref. no. p111l1n3n92n0nn11n, s , 093600145 mpcb micro-processor based motor protection relay micom p211-b, schneider electric make, v
Tender For corrigendum : supply of eil d d - e4953196 numerical relays 01-sg4950387111-numerical o_slash_c and e_slash_f relay for incomer_slash_tie_slash_bc as per annexure-a it-001 _50_slash_51_slash_50n_slash_51n_slash_25_ , 02- sg4950387120-numerical trafo protection relay as per annexure-a it-002 _50_slash_51_slash_50n_slash_51n_. , 03-sg4950387138- numerical o_slash_c and e_slash_f relay for capacitor feeder_slash_og as per annexure-a it-003. , 04- sg4950387146-numerical motor protection relay as per annexure-a it-004. , 05-sg4950387154-numerical motor differential _slash_ ref. protection relay as per annexure-a it-005 , 06-sg4950387162-numerical line diff relay as per ann-a it-006 , 07-sg4950387170- numerical motor protection relay with reverse power function as per annexure-a it-007. , 08- sg4950387189-numerical under voltage relay as per annexure-a it-008. , 09-sg4950387219-ethernet switches _24 cu plus 4 fo_ as per ann-a it-009. , 10- sg4950387227-cat-6 cable as per ann-a it-010. uom- meters , 11-sg4950387235-fo cable as per ann-a it-011. uom-meters , 12-sg4950387243-data concentrator panel as per ann-a it-012. , 13-sg4950387251-human machine interface _hmi_as per ann-a it-013. , 14- sg4950387278-relay parameterization device for dc as per ann-a it-014. , 15-sg4950387286-global positioning device as per ann-a it-015. , 16- sg4950387294-report printing device as per ann-a it- 016. ) /bid number : gem/2026/b/7405586 * /dated: 31-03-2026 & & / bid document 1 / 18
Tender For corrigendum : supply of numerical relay for i/c & b/c protetion , numerical relays for uf/uv protection , numerical relay for adv. fdr. protection , numerical relay for motor protection
Tender For supply of supply of 3 pole power contactor type ml12 with aux contact cat no. ss91010 make: l&t coil voltage , supply of electronic motor protection relay model: mm10 cat no. mm10240e005 make: l&t
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - s/i/t/c of new 80 hp vt pump set, supplying,installation,testing and commissioning of vt pumpset (confirming to is1710:2021 standards) with 35 ft suitable size ms column pipe assembly in random length of 5 ft.(make-jyoti/wpil/kirloskar) with ss/bronze impeller capable to discharge 216 m3/h against a total head of 68m coupled with vertical solid shaft tefc ie3,ip55 type squirrel cage induction motor (make-siemens/crompton/abb) operating on 3 phase 50 hz,415v+- 10% supply and having speed 1400-1500 rpm (bhp of motor should be 10% more than that of pumpset including cost pof supplying,fitting and fixing of all required accessories, repairing of 80 hp vt pump set at raw water, supplying all labour tools and tackles for taking out the 40hp vt pump set with bowl assembly, column pipe and line shaft etc., cost towards dismantling of complete bowl assembly., cost towards repairing and fitting the parts of vt pumpset as per requirement (works as complete overhauling of the pump) such as:-1.machining/lathe work 2.changing ss top shaft,line shaft(2 nos of 5 feet) of and bottom shaft2.repairing of bowl assembly and impleller3.supplying and fitting c.l spider bearing with rubber cut less bush-4nos4.supplying and fitting of worn-out nut-bolts,bolt-nut washer,gland body bush machining,other machining works,etc as per requirement, complete assembling the pump set and lowering including supplying all petty materials., cost for supplying and installation of required accesories for repair and maintenance of motor control panel such as:-150 amp contactor-2 no (for 1 no starter)160 amp,breaking capacity -36ka mccb 1 no56-90 a electronic overload relay-2 nostimer-2 nosvolt meter 1 nosamp motor 1 nospilot lamp 6 nosselector switch 4 nossingle phase preventer 2 nos[ all accessories of reputed make]with complete internal wiring with suitable size of copper wire and testing on load., repairing of 30hp c/f pump sets at clear water, cost for dismantling of 30 hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb - 50 amp,25ka,3pole-2 nos (for motor backup protection),mccb -100 amp,50ka,3pole-1 no (main mccb)2.overload relay 26-40 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required, repairing of 15hp c/f pump sets at clear water, cost for dismantling of 15hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb -25 amp,15ka,3pole-2 nos (for motor backup protection),mccb -50 amp,25ka,3pole-1 no (main mccb)2.overload relay 20-25 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required
Tender For supply of door switch for illuminating lamp as per annexure 1 , door switch for led tube as per annexure 1 , emergency stop push button as per annexure 1 , hrc fuse and link as per annexure 1 , indicating lamp as per annexure 1 , time delay relay as per annexure 1 , under and over voltage with phase failure and phase reversal protection relay as per annexure 1 , motor protection on delay timer 1no plus 1nc as per annexure 1
Tender For numerical motor protection relays (draw-out type) to retrofit in place of mchnm alstom make motor protection relay for the ht motor protection
Tender For supply of electricla spares and supplies - 3.7 kw motor rewinding, 4-way jb installation with support — 400w light for planning &, store area, led lights 400w installation with support — planning & store, area and other locaiton as advised, 4c × 4 sq.mm cable laying — mcc to commercial shed, loading/unloading boom-a lcs, conveyor boom-a motor,, bypass conveyor boom-a motor, bypass conveyor boom-b, motor, conveyor boom-b motor and other locaiton as advised, 3c × 2.5 sq.mm cable laying — mcc to commercial shed:, conveyor boom-a lcs, bypass conveyor boom-a lcs, loading &, unloading boom-b lcs, conveyor boom-b lcs, bypass conveyor, boom-b lcs and other locaiton as advised, 75 × 50 mm cable tray angle & support — commercial shed, loading & unloading boom, 4c × 16 sq.mm al cable laying — storage shed du new motor, and other locaiton as advised, 4c × 1.5 sq.mm cable laying — filling shed du new lcs, mcc for, new purging unit, valve changing shed to mcc for new valve, changing machine lcs, dpt shed to mcc for new valve, changing machine lcs, 4c × 2.5 sq.mm cable laying — mcc to 24-head carousel, earthing relay, mcc room to 48-head carousel earthing , to 12-, head carousel earthing, 2c × 1.5 sq.mm cable laying — lpg pump house jb to lcs &, instrument for lpg pump, 12p × 1.5 sq.mm cable laying — lpg pump house jb to jb, instrument for lpg pump, 4c × 4 sq.mm cable laying — lpg pump house to mcc for lpg, pump lcs, 4c × 4 sq.mm cable laying — filling shed to mcc for conveyor, dus, earth pit installation — commercial shed (earth digging, gi pipe, fitting, chamber making, gi busbar, chequer plate frame &, chequer plate), earthing strip laying 50 × 6 mm — commercial shed earth pit to, 47.5 kg filling scale, platform structure — dismantle, filling shed near 24-head, carousel, weight scale unit stand & base frame fabrication & installation, — commercial shed, 4c × 16 sq.mm cable laying — valve changing shed to mcc for, new valve changing machine motor, dpt shed to mcc for new, valve changing machine motor, storage shed to mcc for new, du motor, lpg pump house telephone shifting & cable laying, cable tray 75 × 50 mm laying with angle support — commercial, shed, valve changing shed, storage shed, ms plate 1500 mm × 1500 mm × 6 mm modification &, installation — commercial shed hydraulic jack, lightning arrestor height extension for lps (tt gantry rooftop /, filling shed top), new lightning arrestor installation for lps (filling shed &, commercial shed top), earthing strip dismantling & shifting 50 × 6 mm for earthing grid, msv area / lpg pump house manifold & msv manifold /, planning room / storage shed), earthing strip installation 25 × 3 mm for pipe-end flange (receipt, station fencing — all areas / tt parking area fencing / pump, house manifold & msv manifold), hydrant monitor height extension — dismantling and, installation, pipe cutting and welding with flange (tt parking, area / commercial shed loading and unloading), hydrant monitor structure and platform with railing shifting,, fabrication and installation (tt parking area), hydrant monitor railing fabrication and installation (near, counting platform / near lpg pump house / msv area), gi fencing fabrication and installation (3 m × 2 m) — near, counting platform, earthing strip laying with clamp & fabrication 25 × 3 mm (lpg, pump house shed roof to bottom and other locaiton as advised), water pipe 1" line installation with fitting (commercial shed, composite cylinder area), ovcm vent pipe 1" line modification with flange joint (filling, shed), sprinkler pipe 2" line cleaning & modification with flange joint, (msv top area), commercial shed evacuation — vent pipe 1" line modification &, installation with flange joint, conveyor and gi pipe dismantling work — length 45 mtr., (commercial shed valve changing shed connecting platform), platform installation for valve opening of cylinder (filling shed), stand fabrication &