Web Analytics Made Easy - StatCounter

Earthing Cable Tenders

Get complete information related to latest Earthing Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earthing Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earthing Cable Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45728340 Due date: 17 Aug, 202617 Aug, 2026 NA
Tender For supply of set of earthing cable for wag-9 as per specn. no.clw/es/3/0112/c [set details asper category book attached in doc. tab]. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45730208 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of flange jointing for btpn tanks to rdso drg.no.- wd-86081-s-66, item no.11, alt. no.14 or latest [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45731220 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For supply of insulated copper earthing cable as per is 191 size 95sq.mm & length 66 inch - 68 inch along with both end terminal crimping socket size 95 sq.mm - 100 sq.mm. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45736862 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For supply of insulated copper earthing cable as per is 191 size 95sq.mm & length 19 inch - 21 inch along with both end terminal crimping socket size 95 sq.mm - 100 sq.mm. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45732122 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For supply of earthing cable complete 70 sq.mm for lhb coaches. rcf drawing no.lw71248 alt c. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45719686 Due date: 13 Jul, 202613 Jul, 2026 44.90 Lacs
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

CTN :45738480 Due date: 21 Jul, 202621 Jul, 2026 23.32 Lacs
Tender For supply of 9u rack , 2kva ups with rack and 06 nos 18 ah battery with each set 30 min backup , 2 port io box , earthing terminal box with accessories , chemical type earthing rod with accessories , earthing pit installation job , 12 core ofc cable , lying fibre cable , 25 mm pvc casing caping , 50 mm casing caping , earthing cable 1c 4sqmm , joint closure , fibre splicing per fibre , 3 or 4 pvc pipe , flexible conduit , gi pipe 50mm , duct 40mm , danger tape , route marker , cat 6 cable , jack panel 24 port , switch socket power supply board , power cable 3 core 2.5 sqmm , power cable 3 core 4 sqmm , cat 6 cable 1 mtr , lc e2k ofc patch cable 5 mtr , lc e2k ofc patch cable 10 mtr , otb box with e2k 12 port connector , lugs ring type , 40 mm coupler , charges of i c of supplied equipment , material transportation

CTN :45266096 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For corrigendum : supply of earthing cable complete 70 sq.mm for lhb coaches to rcf drg.no. lw71248 alt. c. matl. & specn. as per drg. & rcf specn. edts 101, rev. c, amndt. 3, corr.- 1 to 10 with annexure 1 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

CTN :45743971 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For supply of earthing cable complete 70 sq.mm for lhb coaches to rcf drg.no. lw71248 alt. c. matl. & specn. as per drg. & rcf specn. edts 101, rev. c, amndt. 3, corr.- 1 to 10 with annexure 1 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]