Tender For corrigendum : supply of traction transformer complete with cooling system like ht cable along with protection shield in passenger compartment and under-frame area, thermostats etc. related protection equipment and safety chain arrangement including termination crimping lugs, cable markers with heat shrinkable sleeves for power and control cable, equipment mounting and earthing hardware and accessories as per attached specification. [ warranty period: 30 months after the date of delivery ]
Tender For supply of 25 kv earthingdischargerod made of resin bonded fibre glass as per rdso specification no.eti/ohe/51 (9/87) rev-1 (03/2019) with latest a&c slip no. 1 (03/2022) complete with cable earthing rail clamps 02 nos. top clamp suitable for fit over round/stranded 10-20 mm dia conductor and circular bus bar of 36 mm - 50 mm outer diameter, with cable 9 meters (length of cable from earthing clamp to top clamp) plus 1.5 m (length of cable from insulated tee junction to other earthing clamp) and a rugged canvas carrying bag for each dischargerod. [ warranty period: 30 months after the date of delivery ]
Tender For providing and fixing of wti, oti and protection system of protection system of power transformer installed at 33kv main receiving substation and katghodi substation of substation of churcha mine (ro).
Tender For corrigendum : supply of 25 kv earthing /dischargerod assembly as per rdso specn.no.eti/ohe/51(9/87) with a & c slip no.1 or latest. [ warranty period: 30 months after the date of delivery ]
Tender For supply of 25 kv earthing/dischargerod assembly working voltage 25 kv ac traction with top clamp (suitable for 36 to 50 mm bus bar and also suitable for 10 to 20 mm dia. conductor). single core flexible multi strand annealed copper cable should have double insulation and cross section of 40 sq mm of size 248/0.45 mm and 10.5 meter long cable (specifications is: 1554 (pt. i)- 1988 and is 2071 (pt. i and iii). with earthing double clamp drg. no. eti/ohe/sk/482 or latest (each dischargerod is to be supplied with 02 nos. earthing clamps), insulated tee junction- insulated tee junction drg no. eti/ohe/sk/481 and re/33/p/530 or latest (the cable should have an insulated tee junction and the tee clamp should be of brass covered in clamp casing of ebonite material). and whole assembly to be supplied in rugged canvas bag and all shall be as per rdso specification no. eti/ohe/51 (9/87) with latest a and c slip no. 1 (10/92) or latest. after the award of the p.o., the firm must ensure approval of one sample of the dischargerod from the consignee before tpi inspection. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : purchase of electrical safety helmets belts shoes dischargerods gloves - purchase of safety helmets with head lamps, belts, shoes, earthingdischargerods and gloves
Tender For bid to ras corrigendum : supply of bi facial solar panel 550 watt , topcon solar panel 610 watt , cut section of gate valve,globe valve,ball valve,diapharm valve,needle valve,check valve,safety valve,butterfly valve,pnematic control valve 4 inch diameter , cut section of centrifugal pump,gear pump,multistage c f pump,reciprocating pump,screw pump , cut section of shell and tube heat exchanger acrylic material , cut section of reactor with accessories motor,agitatot,support leg,nozzle,manhole,baffels,thermo well,bottom valve , vrf or vrv unit with two indoor unit 2 point 5 tr each and 5 tr capacity out door unit complete with air cooled condenser,accessories and controls,harmetic shield type compresor,r410 a single phase , evacuating and charging station as above but fitted with weighing scale 0 point 25 hp,230v,50 hz with gauge manifold , gauge manifold with gauges different size of hoses for r134a,r22,r32 and r 410 , wash bag cover jacket for ac service indore 1 point 5 ton,2 point 5 ton capacity , safety belt, industrial type full body protection double rope double hook,100 kg human weight , embroidery machine , brake test arrangement with two spring balance 0 to 25 kg rating , automatic motor coil winding machine with step arbor , three phase variable auto transformer ac varic 3 phase , 0 to 440v, 25a, 50 hz , synchronous motor, with accessories , vfd ac drive ac motor drive with vvvf control 3 phase , single phase transformer, core type, air cooled,1 kva,240 or 415 v,50hz , stepper motor with digital controller , bipolar , 12v dc , input pulse 5v, step angle 1 point 8 , power supply 230 v ac , oprating condition 0 to 40 deg c , bldc motor fan with controller 40 watt , servo motor with contoller 300rpm,12v dc,6mm dia and 15mm legth shaft ,holding torque 30kg cm,no load current 0 point 8 amp,full load current 7 point 5 amp , electrical test bench integrated with 0 to270v ac variac 25a , synchronization trainer for laboratory , solid flow measurement set up bi facial solar panel 550 watt,efficiency 21.3 percentage,dimension 2285mm x 1134mm x 35 mm,anodized aluminumsilver frame,connector mc4 ev02,maximum system voltage 1500v dc, topcon solar panel 610 watt,efficiency 22 point 6 percent to 22 point 9 percent,n type topcon,dimension 2382x1134x30 mm,2 mm dual glass,maximum system voltage 1500v dc, cut section of gate valve,globe valve,ball valve,diapharm valve,needle valve,check valve,safety valve,butterfly valve,pnematic control valve 4 inch diameter, cut section of centrifugal pump,gear pump,multistage c f pump,reciprocating pump,screw pump, cut section of shell and tube heat exchanger acrylic material, cut section of reactor with accessories motor,agitatot,support leg,nozzle,manhole,baffels,thermo well,bottom valve, vrf or vrv unit with two indoor unit 2 point 5 tr each and 5 tr capacity out door unit complete with air cooled condenser,accessories and controls,harmetic shield type compresor,r410 a //bid details 2 / 25