Get complete information related to latest Earthing Rod Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earthing Rod Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earthing Rod Tenders.
Tender For m and r work under edd- rania -- loading 8.5 m long pcc pole from electricity storage centre jainpur on own vehicle and taking it to work site and unloading it safely through unpaved road. a loading 11 m stp pole from electricity storage centre jainpur on own vehicle and taking it to work site and unloading it safely through unpaved road. a transport of electric line material like conductor, clamp, nut-bolt wire, lt cable, stonepad, station set, xlpe, abc etc. to the specified place by own vehicle for an estimated distance of 75 km through unpaved road. a digging pit at the place of broken/damaged poles and installing pcc poles by tying all accessories like cross arm, disc, pin insulator etc. and fitting earthingrod. a tying all accessories as per requirement in the long span in the middle of the already constructed line. the work of re-energizing by installing additional pcc/stp poles as per the prescribed standard/specification of response link. a the work of re-energizing by installing additional pcc/stp poles as per the prescribed standard/specification of response link while tying all the accessories as per requirement in the middle long span of the already constructed line. a installation of new section double pole in place of broken/damaged double pole. a grouting work of pcc/stp poles as per respo standard. supplying cement, ballast, gravel in the ratio of 1:2:4. repairing section double pole. tightening damaged stays by renosing. tightening the white wires of 33 kv line, each wire and tightening the white wires of lt and 11 kv line, each wire. straightening the skewed poles of 33 kv line/11 kv line/lt line as per respo standard and tying all accessories and erecting them correctly. giving clearance by trimming the trees of 33/11 kv and lt line. spreading the acsr vessel conductor in 33/11 kv line and tying stringing and sagging insulators in all the three phases and jumpering and earthing each wire. replacing damaged cross arm.send feedbackside panelshistorysaved
Tender For corrigendum : works related to storm/cyclone (natural calamity) within the limits of v.v.khan., banda (city). - the work of special maintenance and repairing of 11 kv ht and lt damaged lines of various places under various 33/11 kv sub-stations due to heavy storm under daiviya apada/o&m year 2025-26 under edd, banda (town), including carriage of all required material from esc banda to work site, alongwith its loading, unloading & dragging at the respective ends and also safe carriage of old line material/scraped from site to store centre. the bidder shall be responsible for complete execution of the work under the scope of tender specification. any work/activity not specifically indicated but is required for systematic execution of job shall be carried out by the contractor without any extra payment. the material supplied by contractor should be the best quality and as per standard including transportation, if any. details of the work as given below ;-, safe cartage of 8.5 mtr. long pcc poles, safe cartage of 11 mtr. long st poles, safe cartage of line material, erection of newly erected 8.5 mtr. long pcc poles as single support structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., erection of newly erected 11 mtr. long st poles as single pole structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., erection of newly erected 8.5 mtr. long pcc poles as double pole structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., erection of newly erected 11 mtr. long st poles as double pole structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., concreting/grouting of newly erected 8.5 mtr. long pcc poles as single support/double pole structures. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 cu. mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge., concreting/grouting of newly erected 11 mtr. long st poles as single support/double pole structures. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 cu. mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge., erection and grouting of stay set including the work of nozelling etc. as per resspo manual and also including the cost of all grouting material., fixing of earthingrod as per direction of supervising engineer/resspo manual. including the cost of labour, t&p etc. required for proper completion of work., laying, sagging, stringing, binding and jumpering of new acsr weasel conductor on the erected poles in 11 kv ht/lt lines also providing in-place of damaged/misplace conductor due to heavy storm., laying, stringing, binding and termination etc. of abc cable of various size on the erected poles as per direction of supervising engineer/resspo manual., re-sagging of loose conductor of 11 kv ht lines at various places., re-sagging of loose conductor of lt lines at various places., dismentling & removal of existing/erected old & damaged pcc/stp/joist/rail poles as single pole structure with its accessories., dismentling & removal of existing/erected old & damaged pcc/stp/joist/rail poles as double pole structure with its accessories., carriage of damaged/rusted st/rail/joist poles from work site to esc., replacement of damaged/misplace "v" type cross arm, guarding with fitting of all accessories as per resspo manual., dismentling & removal of damaged weasel conductor with its accessories due to heavy storm and also cartage of old/damaged & scrap line material from work site to store centre/je(s)., straightening of tilted single support as 8.5/1
Tender For corrigendum : supply of ms rod 30mm dia , ms rod 8mm , ms rod 10mm , ms rod 40mm , ms rod 40 x 5 mm , ms flat 50 x 5mm , aluminium rod 40mm dia , aluminium ingot , welding rod 3 point 15 mm , welding rod 2 point 15 mm , brazing rod , flux borax , welding rod cast iron , gas welding rod , refilling of oxygen gas , refilling of acetylene gas , grinding disc 4 inch , grinding disc 5 inch , standing disc 4 inch 36 grit , standing disc 4 inch 100 grit , standing disc 5 inch 36 grit , standing disc 5 inch 100 grit , cutting wheel 4 inch dia , cutting wheel 5 inch dia , backing pad for sanding disc 5 inch , sanding sleeve 36 grit , sanding sleeve 100 grit , pop up rivet aluminium 3 mm , pop up rivet aluminium 4 mm , pop up rivet aluminium 5 mm , buffing wheel white cloth , buffing cake , cutting wheel 355mm , bentonite powder , parting sand , graphite powder , coal dust , headless nails , suhaga flux , cotton hand gloves , araldite adhesive 200 gm , masking tape 1 inch x 30m , fevicol sh , nails assorted sizes , pvc bidding patti , fevicol heatex , self tapping screw 2 inch , self tapping screw 1 and half inch , soft wood scantling 3 inch x 3inch , emery paper , air compressor hose , paint yellow , paint red , paint black , paint blue , turpentine , touchwood , red oxide primer , resin with hardner , pigment colour 15 gm packet
Tender For supply of discharge /earthingrods assembly as per rdso specification no- eti/ohe/51(9/97) rev -1 (oct98) and core-ald approved drg. no. power/rly/786. make- international motors, internati onal engg kolkata and power equipment or similar [ warranty period: 30 months after the date of de livery ]
Tender For supply of solar panel , solar inverter , solar acdb box , solardcdb box , generation meter , mcb , rcb , earthingrod , panel bracket , solar street lamp , 6 mtr gi pole
Tender For discharge rod/ earthingrod assembly complete fully made of fibre glass light weight for 25kv working voltage ac traction as per rdso spec no. eti/ohe/51(9/87) rev. 1(oct 92) light weight 11 kgs app roximately, each discharge rod is supplied with 02nos rail clamps suitable for 10 - 20mm dia conductor & c able 10 metre long, whole assembly to be supplied in canvas bag. note: 1) warranty period will be as per i rs conditions. 2) one sample should be got approved before effecting bulk supply. [ warranty period: 30 months after the date of delivery ]
Tender For discharge /earthingrod for 25 kv ac supplycomplete with 10 meter cable w ith top clampand eartihing clamp .as per rdso specn.no.ohe/51(9/87)latest,with canvas b ag in three fold [ warranty period: 30 months after the date of delivery ]
Tender For supply of 25 kv earthing/discharge rod with working voltage 25kv ac traction to rdso specification no. eti/ohe/51 (9/87) with latest a and c slip no.- 1 (10/92)& drg no: earthingrods.- re/33/p/510 or latest, earthingrod- re/33/p/511 or latest ,earthingrod hook assembly, -re/33/p/520 or latest , earthingrod head- re/33/p/521 orlatest, earthingrod tongue -re/33/p/522 or latest, earthingrod hook pin and other smallpart s -re/33/p/523 or latest, insulated tee junction- re/33/p/530 or latest. each discharge rod is to be supplied with 02 nos. rail clamps, the top clamps suitable for 10, 12 mm dia conductor 1 no. each and cable 7.5, 1. 5 mtr. (whole assembly is to be supplied in a canvas bag) [ warranty period: 30 months after the date of delivery ]
Tender For supply of spv module above 400 wp , ongrid inverter , mounting structure , battery 12v 75 ah , battery stand , battery interconnection wires and lugs 10 meter , solar irradiation meter , mc 4 series connectors , mc 4 parallel connectors branch , solar grade dc cable 4 sq mm 20 meter , green yellow earthing wire 6 sq. mm 20 meter , cable ties uv protected 50,100,mm 2 packs , ac - db , dcdb 3 in 3 out with spd , solar panel 75 w 12 v , charge controler 12 v 5 a , battery 12v, 20ah , led bulb 5 w , solar lantern 5 10w , connecting wires 10 mtr , mechanical fixtures , ac wire 3 core acdb to inverter 5meter , ac 3 core cable 2.5 sq. mm 30meter , screw and pvc buffer for mounting acdb and dcdb , petroleum jelly for battery terminal small 10 paks , water level tube with holder 10 meter , sprit level magnetic base , inclinometer magnetic base , 30-meter fiber tape , hammer screw driver , tri square 8 inches , metal measuring tape with level 5 m , self adjusting wire stripping pliers , 30 meter extension wire , flat and ring spanner set , torque wrench with adopter , ball pin hammer , digital multimeter , digital ac and dc clamp meter , crimping tool , hammer drill machine , set of drill bit for concrete , set of hss drill bit for metal , cutting wheel and grinding wheel , hot gun gas electric operated for sleeves , pair of solar mc 4 connector wrench tools , hydrometer , battery load tester , digital earth tester , cable insulation tester megger , hand gloves , safety jacket , safety full body harness , anti-slip safety shoes , safety goggles , head helmet hard hat , anchor lifeline , safety static rope , first aid kit , sinamics g120c , siemens g120 iop 2 , 3 phase induction motor 1.5 kw 1.5 hp , sinamics v90 servo drive , simotics s-1fl6 servo motor , power cable for servo motor , siemens v90 incremental encoder cable , microstep driver dm542 , stepper motor , rotary encoder incremental pnp , siemens hmi ktp400 basic touch pane , earthingrod , pyronometer , wire gauge
Tender For m and r work under edd- rania -loading 8.5 m long pcc pole from electricity storage centre jainpur on own vehicle and taking it to work site and unloading it safely through unpaved road. a loading 11 m stp pole from electricity storage centre jainpur on own vehicle and taking it to work site and unloading it safely through unpaved road. a transport of electric line material like conductor, clamp, nut-bolt wire, lt cable, stonepad, station set, xlpe, abc etc. to the specified place by own vehicle for an estimated distance of 75 km through unpaved road. a digging pit at the place of broken/damaged poles and installing pcc poles by tying all accessories like cross arm, disc, pin insulator etc. and fitting earthingrod. a tying all accessories as per requirement in the long span in the middle of the already constructed line. the work of re-energizing by installing additional pcc/stp poles as per the prescribed standard/specification of response link. a the work of re-energizing by installing additional pcc/stp poles as per the prescribed standard/specification of response link while tying all the accessories as per requirement in the middle long span of the already constructed line. a installation of new section double pole in place of broken/damaged double pole. a grouting work of pcc/stp poles as per respo standard. supplying cement, ballast, gravel in the ratio of 1:2:4. repairing section double pole. tightening damaged stays by renosing. tightening the white wires of 33 kv line, each wire and tightening the white wires of lt and 11 kv line, each wire. straightening the skewed poles of 33 kv line/11 kv line/lt line as per respo standard and tying all accessories and erecting them correctly. giving clearance by trimming the trees of 33/11 kv and lt line. spreading the acsr vessel conductor in 33/11 kv line and tying stringing and sagging insulators in all the three phases and jumpering and earthing each wire. replacing damaged cross arm.