Web Analytics Made Easy - StatCounter

Earthing Work Tenders

Get complete information related to latest Earthing Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earthing Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earthing Work Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45426314 Due date: 01 Jul, 202601 Jul, 2026 8.57 Lacs
Tender For corrigendum : name of work:- plinth, fencing and earthing works of converters in business plan 2026-27 under electricity distribution section-mankapur area.

CTN :45426434 Due date: 01 Jul, 202601 Jul, 2026 9.88 Lacs
Tender For corrigendum : name of work:- plinth, fencing and earthing works of converters in business plan 2026-27 under electricity distribution section-nawabganj area.

CTN :45742918 Due date: 07 Jul, 202607 Jul, 2026 8.72 Lacs
Tender For supply, installation, testing and commissioning of load management panel and earthing work at nccbm ballabgarh

CTN :45426181 Due date: 01 Jul, 202601 Jul, 2026 9.78 Lacs
Tender For corrigendum : name of work:- plinth, fencing and earthing works of converters in business plan 2026-27 under electricity distribution section-nawabganj area.

CTN :45426189 Due date: 01 Jul, 202601 Jul, 2026 9.45 Lacs
Tender For corrigendum : name of work:- plinth, fencing and earthing works of converters in business plan 2026-27 under electricity distribution section-nawabganj area.

CTN :45426248 Due date: 01 Jul, 202601 Jul, 2026 9.87 Lacs
Tender For corrigendum : name of work:- plinth, fencing and earthing works of converters in business plan 2026-27 under electricity distribution section-nawabganj area.

CTN :45426316 Due date: 01 Jul, 202601 Jul, 2026 9.30 Lacs
Tender For corrigendum : name of work:- plinth, fencing and earthing works of converters in business plan 2026-27 under electricity distribution section-mankapur area.

corporations/Associations/Others

CTN :45711581 Due date: 03 Jul, 202603 Jul, 2026 37.20 Lacs
Tender For strengthening work of 33 kv line, strengthening work of 11 kv line, strengthening and protection of 33 11 kv sub-stations, 11 kv vcb work, 33 kv vcb work, switch yard work 11 0.4 kv distribution transformer plinth fencing earthing work bp 2026-27

CTN :45423602 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For bid to ras supply of led batten light (led tube light) (v2) (q2) , led luminaire for floodlight conforming to is 10322 (part 5/section 5) (v3) (under bis scheme - ii) (q2) , led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , plastic bib taps, pillar taps, angle valves & stop valves for hot & cold water services conforming to is 9763 (q3) , copper alloy taps/stop valves (v2) conforming to is 8931 (q3) , self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii) (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , astronomical time switch based on lux level , bell ding dong call bell , bell push 6 amp piano type , cable lugs alumn 120 sqmm , cable lugs alumn 150 sqmm , cable lugs alumn 185 sqmm , cable lugs alumn 25 sqmm , cable lugs alumn 35 sqmm , cable lugs alumn 50 sqmm , cable lugs alumn 95 sqmm , cable pvc insulated copper single core 2 point 5 sqmm , cable pvc service al 2 core x 10 sqmm , cable pvc service al 2 core x 4 sqmm , cable pvc service al 2 core x 6 sqmm , mcb sp 25 amps , mcb 4 pole 40 amp , mccb 100 amps 4 pole 25 ka , mccb 200 amps 35 ka 4 pole , mccb 250 amps 35 ka 4 pole , ht 11 kv heat shrink straight through jointing kit for cable 95 sqmm , booster pump 1 hp single phase , cable copper 25 sqmm single core , cable copper 35 sqmm single core , cable copper 50 sqmm single core , lugs copper 25 sqmm , lugs copper 35 sqmm , lugs copper 50 sqmm , lugs copper 70 sqmm , flat copper cable 10 sqmm 3 core for submercible , flat copper cable 6 sqmm 3 core for submercible , mcb 4 pole 63 amp c series , hrc fuse 100 amp with copper lever , hrc fuse 200 amp with copper lever , ht cable end joint heat shrink outdoor of size 120 sqmm , ht cable end joint heat shrink outdoor of size 95 sqmm , ht 11 kv heat shrink straight through jointing kit for cable 120 sqmm , led bollard light 12 watt , led gate light 12 watt outdoor waterproof , led recessed luminer light 16 watt , led recessed mounted panel light 18 watt , power contactor 4 pole 70 amp , pvc insulated frlsh single core copper conductor 4 sqmm size , socket 16 amp flush type , socket 6 amp flush type , ht fuse element 11 kv voltage grade 10 amp , pvc tape roll 40 mm , led street light driver 45 watt , led street light driver 60 watt , on load change over switch 4 pole 40 amp with encloser , on load change over switch 4 pole 630 amp with encloser , mccb 400 amps 50 ka 4 pole

Central Government/Public Sector

CTN :45697300 Due date: 16 Jul, 202616 Jul, 2026 20.00 Lacs
Tender For maint of road side lighting works and miscellaneous electrical items under ge n akhnoor. - labour for cutting/pruning of tree branches along security light pole around 2 mtr radius of security light fitting and removing from site including arrangement of t&p (i.e. axe, rope & ladder etc.) complete all as specified and directed., dismantling and taking down street light fittings/post top lantern/down lighter of any wattage/size for repair or replacement of burnt/worn out accessories or carrying to mes store and refixing after repair on required location complete all as directed.note: accessories or components needed for replacement shall be measured and paid separately under appropriate items., repairing of unserviceable led street light any make/model of 90 100 watt capacity by replacing compact led electronic driver suitable to operate on 120 to 270 volt, 50/60 hz ac supply, protection grade ip-66 with surge protection complete all as specified and directed., repairing of unserviceable led street light any make/model of 60 72 watt capacity by replacing compact led electronic driver suitable to operate on 120 to 270 volt, 50/60 hz ac supply, protection grade ip-66 with surge protection complete all as specified and directed., pvc conduit medium grade of size 15 mm bore including fittings, isi marked, fixing with pcc pole/steel tubular pole/garden lights/gate lights for wiring connection from pole box to light fitting and supporting with 03 nos gi strip clamp, nut & bolt, complete all as specified and directed., replacement of pvc insulated pvc sheathed stranded copper conductor cable 2.5 sqmm twin core complete all as specified and directed., pvc insulation tape of width 18 mm, thickness 0.125 mm, length 25 mtr, isi marked, for proper insulation of joints in wire where required or directed., replacement of aluminium pvc service wire 2 core 6 sqmm flat roll of 90 mtr, superior quality, complete all as specified and directed., disconnecting & dismantling of damaged/unserviceable cable of any type/make and supply & laying in repair/replacement of cable xlpe insulated, screened pvc bedded, galvanized steel strip or wire armoured electric power cables (heavy duty), 1100 volts grade with stranded aluminium conductor using lugs/ferrules at both ends of cable and testing complete all as directed for following sizes:, 10 sqmm 4 crore, 16 sqmm 4 crore, 25 sqmm 3.5 crore, 35 sqmm 3.5 crore, note for item no. 17 & 18: excavation & earth work, sand cushioning, bricks protection & gi pipe where required shall be measured and paid separately., excavation in trenches not exceeding 1.5 mtr width and not exceeding 1.5 mtr depth, getting out for electric cable complete in any type of soil complete all as specified and directed., removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point, complete all as specified and directed., returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed., supply and laying sub class b bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed., sand cushioning with ganga sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable) complete all as specified and directed., replacement of 40 mm gi tubing light grade with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor/as garden post including 2 nos mild steel fi clamps 35 3 mm size to support pipe with pole complete all as specified and directed., boring under road horizontally of size 40/50 mm bore using gi pipe for passing of cable in road/path in hard/soft/loose soil complete all as specified and directed., applying two coats of aluminium paint over a coat of red oxide on steel tubular po
 Loading, Please wait...

Connect us via What's Up