Web Analytics Made Easy - StatCounter

Earthmoving Equipment Tenders

Get complete information related to latest Earthmoving Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earthmoving Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earthmoving Equipment Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :40673477 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For corrigendum : supply of electrical parts and equipment testing e e - motor repair charges , pi testing , ir testing , thermography , acb vcb tesing , relay testing , transformer oil filtration and oil sample testing , insulation mat , load testing of battery bank , calibration of equpiments , explosive meter multi gas , vibration analysis of motors and pump , transformer wti oti testing , vcb bottle , calib tan delta , energy meter calibration , volt meter calibration , dfra testing of transformer , sfra testing of transformer , rla of vcb , rla of transformer , arc flash study , partial discharge of transformer , clamp meter , supply of digital lux meter , dry film thickness meter , wet film thickness meter , hand gloves 11kv , hand gloves 33kv , silica gel , occupancy sensor , elcb , anchor fastner , ceiling fan size , concealed light , repair of ceiling fan , pvc gitti with screw , pvc saddle , led tube light 22 watt , petroleum jelly , emergency light , plastic exhaust fan 14 inch , plastic exhaust fan 12 inch , insulation tap , aluminium lug ring type , aluminium lug ring type 50mm , copper lug ring type , supply of fan capacitor , battery terminal , salt bags 25kg no gst , supply of flp push button and indicator , supply of mcb single pole , supply of exhaust fan300mm flp , locating of cbl faultexca backfilling , supply of crocodile cliphvydty f earth , battery water , mseal , flp extension board , one socket switch board 6 16a of any reputed brand , media convertor , energy meter mfm , gateway rs485 to ethernet , ofc cable set of 4 , cable tray laying 100mm , visit charges by a class electrician , supply and install of capacitor 10kvar , supply and install of capacitor 20kvar , supply and installation of new capacitor in existing panel , cat 6 arm , cable tie size 100mm , cable tie size 150mm , cable tie size8 300mm , cable drag chain , spanner cu ti 36 300 , spanner cu ti 90 780 , hdmi cable , sup and inst of gigabit switchtestg comm , extender adapto reactor assy , clip terminal electrical , sup inst swtype 8 portdata testng and co , sup instl test commcat 6 24 port loaded , dp port to hdmi port connectors , hdmi to dp port convertor , adaptor 5 amp , smoke detectors new non flp , supply installation of hdmi to vga converter allows a single hdmi channel to be converted to analog vga rgb. vga to hdmi convertor adaptor , power over ethernet poe injector splitte , annoucment system repair ahuja ssa 250 , smoke detectors testing bottel solo , test kit solo detector , heat detector testing kit , cpu repairing , supply of insulation mats as per hpcl approved make , charcoal bags 25kg no gst , extension board rat16a 10mt

corporations/Associations/Others

CTN :39986654 Due date: 07 Jul, 202507 Jul, 2025 NA
Tender For corrigendum : custom bid for services - verification and health checking of bently-nevada make turbine differential expansion etc of ctps u7 during the coh-01) health checking verification, replacement if any, refitting & commissioning of:- a) all bearing and shaft vibration sensors and related modules of turbine/generator bearing. b) lpt differential expansion sensors and related modules at turbine brg no.-4. c) axial shift sensor and keyphasors sensors. d) bearing vibration sensors and keyphasors and its related modules of id fans, fd fans, coal mills, pa fans, cw pumps, ceps and bfps. e) all the cables associated with the above measurements. f) work related to running unit 8 ctps as per availability of work front and up to extent possible. 02. preparation of documentation like verification report of sensors and modules. 03. work assistance:- the entire job is to be carried out by m/s ge oil & gas india private limited. however, dvc will provide work assistance of technicians and helpers to carry out the said jobs. 04. any special tools like shacker table, tk 3e or other equipment s require for the execution of the above mentioned job, especially for lp turbine deferential measurement system are to be brought by m/s ge oil & gas india private limited. 05. all the spares will be provided by dvc..

CTN :40869923 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For providing of repair and overhauling service - 4371 vibration analysis of main equipment onboard in lcu 52; vibration analysis of main equipment; no; buyer premises

State Government

CTN :40841890 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso

CTN :40438608 Due date: 19 Jun, 202519 Jun, 2025 NA
Tender For supply installation and commissioning of physics lab at item wise on turnkey basis at govt new model college jhabua 457661 mp india - supply installation of physics lab equipment on turnkey basis, battery charger 2 to 12 volt., ballistic galvanometer with lamp and scale arrangement, spectrometer prism (crown/flint glass), spectrometer 6" 17 ", 30 sec, optical bench with riders double bar, optical bench with riders double bar heavy, inertia table, complete apparatus to verify law of parallel and perpendicular axes for moment of inertia, compund pendulum/bar pendulum, reading telescope, bending of beam apparatus to determine youngs modulus, cantilever to determine youngs modulus, horizontal torisonalpendulamappratus, jaeger apparatlrs to deternrine the surface tension, apparatus to determine the surface tension, apparatus to determine the viscosity of fluid using poiseuiles method, callendor and barnes apparatus to determine the value of mechanical equivalent of heat, measurement of low resistance by carey, potentiometer, lee purpose to determine the hear conductivity of bad conductor of different geometry, apparatus to verify newtons law of cooling, searl apparatus to determine the coefficient of thermal conductivity, sodiurn vapour lamp, transformer for sodium vapour lamp, mercury lamp, transformer of mercury lamp, biprism, complete apparatus to determine the resolving power of a telescope, biquartz are half shade polarimeter, newtons ring apparatus cornplete with travelling microscope power supply and sodium level, electroscope or electrometer, audio fiequency generator, cro dual trace 30 megahertz single tress l0megahertz, i.jse of vibration magnetometer to study a field apparatus, tangent galvanometer, apparatus to study resonance curve for lcr circuit, apparatus for measurement of capacitance and inductance, apparatus to determine the value of plancks constant, complete apparatus to determine e/m using thomson method, complete apparatus to determine e/m by milikons method, apparatus to study the absorption spectra of iodine vapour completes with white light source power supply grating and spectrometer, apparatus to draw bh curve of ferromagnetic material with the help of cro, half wave and full wave rectifier apparatus with built-in power supply, transistor characteristics apparatus with built in power supply and metres, apparatus to study characteristic of tunnel diode, apparatus to study hysteresis curve of transformer core, apparatus to study specific resistance and energy gap of a semiconductor, apparatus to study transistorized regulated power supply, apparatus to study rc coupled amplifier with built-in power supply, zener diode characteristics apparatus with built-in power supply, apparatus to study charging and discharging of a capacitor, complete setup to find the wavelength of sodium light, study of lissajous figure trainer, barton apparatus, digital oscilloscope, adjustable height stands, capillary tube packets of different radii, electrical laboratory kettle with varying voltages, piatinum resistance thermometer, soldering station, desoldering tool, thermocouple apparatus, jfet apparatus to study characteristic curve, hall probe apparatus, plane transmission grating, brewster law apparatus, beam divergence apparatus of helium neon laser, diode laser, holographic diffraction grating, michelson interferometer, logic gates apparatus (or, and not, nand, nor, xor), standard tool box, connecting lead wire for electronic apparatus, flywheel
 Loading, Please wait...

Connect us via What's Up