Get complete information related to latest Economizer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Economizer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Economizer Tenders.
Tender For 1) repair maintenance of electrical and mechanical services at mso building, ip estate, new delhi. 2) maintenance of electrical installation and fans, compound light and repair maintenance of pump set installed at dm (central) office 14, daryaganj, new delhi (sh- providing of various equipment at circle office, pwd of
Tender For corrigendum : supply of steam water analysis system main spares and e and c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart material code , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , hc analyzer 4 to 20ma , sample handling system for main steam superheated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for dm water , sample handling system for condensate blow down line , sample coolers , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 2 mandays for 6 nos at site , supervision of e and c services charges at site , supervision of e and c visit charges , mandatory spares as per tech specs
Tender For work of attending leakages by replacing damaged plates and patching of vertical duct from economizer outlet to air preheater in unit 3 during coh at cstps, chandrapur.
Tender For tender for straight heat shield with two nos. clamps for water wall tube dia. 63.5mm , straight heat shield with clamps for ltsh straight for tube dia. 44.5mm , heat shield with clamps for water wall screen straight tube for tube dia. 76.1mm , heat shield with clamps for s.h. screen and hanger tubes of dia. 51mm , straight heat shield with clamps for economizer tubes of dia. 32mm , straight heat shield with two nos. clamps for sh and rh tube dia 48 mm , ss rod 10mm
Tender For overhaul works on boiler pressure parts for replacement of eroded tubes of ltsh, back-pass and economizer tubes and metal filling on eroded tubes where ever required after d-meter survey, inspection, fixing and adjustment of erosion protection shields at unit-6/stage-iv/dr.mvr rtpp during annual overhaul period 2026-27.
Tender For bid to ras supply of top and bottom economizer panels d d - top economizer coil upper straight , top economizer coils upper staggered , top economizer coils central straight , top economizer coils central staggered , lower economizer loop assembly lh , lower economizer loop assembly rh
Tender For providing of facility management services - lumpsum based - industrial; cleaning of boiler economizer tubes; consumables to be provided by service provider (inclusive in contract cost)
Tender For corrigendum : supply of spares of soot blowers of (2x600 mw), katpp, rvunl, jhalawar - "lance tube assembly with flange, nozzel and nozzel head pipe.soot blower location: plsh area (ik-1/2/3/4) in u#1& 2 respectively", "lance tube assembly with flange, nozzel and nozzel head pipe soot blower location: plsh area (ik-5/6/7/8/9/10) in u#1& 2 respectively", "lance tube assembly with flange, nozzel and nozzel head pipesoot blower location: fsh (ik-11/12/13/14/15/16), frh (ik-17/18/19/20/21/22),prh(ik-23/24), ltsh(ik-25/26) area in u#1& 2 respectively ", "lance tube assembly with flange, nozzel and nozzel head pipe soot blower location: prh(ik-27/28/29/30, ltsh area(ik-31/32/33/34/35/36)in u#1& 2 respectively", "poppet valve assembly for all lrsbsoot blower location: plsh/fsh/frh/prh/ltsh area", "poppet valve assembly for hrsbsoot blower location: economizer area", "screw tube (lance tube) with packing assembly for fsbsoot blower location: water wall area", "feed tube with flange for fsbsoot blower location: water wall area", "goose neck valve assembly for fsbsoot blower location: water wall area", "lance tube with multi -jet element nozzel assembly for aphsbsoot blower location: air pre-heater area"
Tender For corrigendum : tender for supply of tubular protector for spacer tube , size l-1000mm , id-55 mm , tubular protector for rear w.w. screen tube , size l-1500mm , id-55mm , tubular protector for final s.h. tube , size l-1000mm , id-55mm , tubular protector for tertiary super heater & reheater size 1500x58.0x4.0 mm , tubular protector for tertiary s.h. tube , size l-1000mm , id-57mm , u clamp of size id-57 mm , u clamp of size id-63mm , tubular protector for economizer & primary s.h. vertical tube , size l-1000mm , id-52mm , tubular protector for economizer & primary s.h. vertical tube , size l-1500mm , u clamp of size id-53mm , tubular protector for pri. s.h. tube , size l-1500mm , id-45mm , u clamp for ash protector of primary sh horizontal size id-45 mm , tubular protector for sec. & ter. rh coil , size l-1500mm , id-64mm , u clamp of size id-65 mm , width 40mm , th.-4.0mm , 90 degree bend tubular shield for primary super heater horizontal size id-45.5 mm , reverse 90 deg bend ash protector for primary sh horizontal size id-45.5 mm , semi circular protector for spacer tube 60 deg bend size-1500x65x4 mm
Tender For corrigendum : daily cleaning of air heater hoppers, economizer hoppers, mill chambers, slag bath pits and basement area, hsd & hfo,mot & dot, unloading pump house, drains, round the clock in three shifts of ph-i and ph-ii, htps, korba (west)