Get complete information related to latest Edge Wall Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Edge Wall Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Edge Wall Tenders.
Tender For renovation of old animal shed at icar-cirb, hisar. (sh- retrofitting of old animal sheds i/e strengthening of beams and columns, steel structure truss i.e. covering of truss and mise. work, modification of manger, change of floor, water supply line plastering and painting of wall and other mise work).subwork/packages:maintenance work
Tender For upgradation of lane and drain in jeevannagar,govindnagar and other allied work at different location, covering of drain near h/o choudhary to onwards r/wall at govind nagar ward 58
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For balance work, retaining wall / edgewall and other allied works n/h/o mohd. aslam supply of late abdul karim to grave yard r/o bagla morh khu talab vijaypur.
Tender For repair & restoration of rain damages link road balmandir upper marwari to village babehar km. 0/0 to 3/400, (sh: p/l interlocking concrete paver block and retaining/edgewall in km 0/660 to 0/700) under pdna 2023
Tender For repair & restoration of rain damages link road andora to shivpur via banne di hatti km 0/0 to 4/200 (sh:- construction of retaining/edgewall near house of sh. ravi thakur adjoining banne di hatti bridge)
Tender For repair & restoration of rain damages link road from gram panchyat nangal jarialan to mohalla kabir panthi, (sh:- construction of retaining/edgewall at rd 0/137 to 0/167 )
Tender For balance work of link road sh. pyar chand house to sh. benjhu ram house km 0/00 to 0/600 (sw- p/l wbm g-ii , g-iii, tarring work and edgewall, grating (mc deposit)