Get complete information related to latest Eeg Paper Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Eeg Paper Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Eeg Paper Tenders.
Tender For bid to ras bid to ras supply of radiological items - intracranial thrombectomy device for stroke , intracranial thrombus aspiration device for stroke , pva particle dry in ampoules particle size to be specified at the time of purchase , pva particles pre filled syringes particle size 180 to200 micron , hydrophilic with m coat agiography glide catheter less lubricity on proxilmal shaft cobral c1 5fr 65 cm 0.038 inch wire , sim1 hydrophilic agiography glide catheter mcoat permitting 0.035 inch guide wire atlist 100 cm long , stiff hydrophilic coating guide wires suitable for negotiating tortuous vascullar anatomy with j curve tip of 0.035 inch diameter and 260 cm length , c2 cobra agiograph glide catheter m coat permitting 0.035 inch guide wire atleast 65 cm long , kampi angiography catheter 40 to65 cm length 4obq5 fr permitting 0.035 inch guide wire , microcatheter length 110 to130cm od distal 2.7 fr and proximal 2.9 fr for peripheral interventional with tungstern coil glide m coating with gtequipvalent glide coating 130 cm length , vertible hydro philic angiographyglide catheter m coat like terumo permitting 0.035 guide wire atleast 100 to 120 cm long 5to6f , stent balloon expandable pre mounted over the wire design shaft length at least 120 cm stent diameter 8 to 10 mm. stent length 15 to 40 mm , stent balloon expandable pre mounted rapid exchange design shaft length at least 120 cm stent diameter 5 to 7mm stent length 10 to 20 mm , stent balloon expandable pre mounted rapid exchange design shaft length at least 120 cm stent diameter 8 to 10mm stent length 10 to 30 mm , transjugular liver access set for tipss , self expanding nitinol stents for carotid angioplasty assorted sizes , sheath vascular access with non reflux access valve sidearm with three way stopcockguidewire and vessel dilator. 4f to 7f diameter and length 10cm , sheath vascular access with non reflux access valve sidearm with three way stopcock. guidewire and vessel dilator 8f diameter and length 10cm , 6 f soft tip guiding catheter for neurovascular procedures like neuron guiding catheter , 6 fr highly flexible intracranial support catheter for aneurysm coiling and flow divertor placement with 0.072 upto 30 cm long like navien , microfabricated nitinol hypotube design synchro guide wire 0.014 diam200 cm length , semi automatic biopsy gun with adjustable throw dual 10to20 mm throw with compatible coaxial needle having blunt sylet for enhanced safetywith fire ready indicator of 16 to 20 g 10 to 20 cm length , flow diverter with at least 48to72 nitinol strands with balanced porosity and mesh density for use in uncoilable and giant aneurysm with antithrombogenic coating 3.5-6 mm diameter 15-50 mm length , thermal printer paper usg type 5 , drug eluting beads for chemoembolization , rotating hemostatic valve y connector tuohy borst , histoacryl glue n butyl cyanoacrylate , guidewire amplatz ultra stiff 0.035 inch diameter 260 cm or more length available with 1 cm 3 cm and 6 cm floppy tip segment , 0.035 radio focus hydrophilic coated guide wire of super elastic alloy radioapque tungsten length 150cm , 0.035 radio focus hydrophilic coated guide wire of super elastic alloy radioapque tungsten incorporated in to the polyurethane jacket length 260cm.
Tender For corrigendum : purchase of structural heart disease interventions and devices for thrombus aspiration (group e ) on one year rate contract basis and further extendable upto 01 years. - e1: ptmc balloon, item no. 1: ptmc balloon inoue type , with accessories, item no. 2: ptmc balloon inoue type , without accessories, item no. 3: ptmc balloon inoue type having two side ports,with accessories, item no. 4: ptmc balloon inoue type having two side ports,without accessories, item no. 5: special ptmc balloon inoue type havingtwo side ports and security thread in vent, with accessories, item no. 6: special ptmc balloon inoue type having two side ports and security thread in vent,without accessories, item no. 7: ptmc balloon inoue type havingone side port, with accessories, item no. 8: ptmc balloon inoue type havingone side port, without accessories, item no. 9: transseptal puncture needle for ptmc, item no. 10: transseptal puncture needle for ptmc (brocken borough type), item no. 11: introducer sheath mullins type for transseptal puncture, item no. 12: special woven sheath mullins type for transseptal puncture, e2: left atrial appendage closure device, item no. 1: left atrial appendage closure device, item no. 2: special left atrial appendage closure device, e3: aortic valve and accessories for transcatheter aortic valve replacement (tavr), item no. 2: special porcine self-expanding aortic valve with suprannular design with delivery system for tavr, item no. 2: special porcine self-expanding aortic valve with suprannular design with delivery system for tavr, item no. 3: special porcine self-expanding aortic valve with suprannular designwith single spine shaft in delivery system for tavr, item no. 4: bovine self-expanding aortic valve with suprannular designwith delivery system for tavr, item no. 5: self-expanding aortic valve with delivery system for tavr, intra-annular design, item no. 6: special self-expanding aortic valve with delivery system for tavr, intra-annular design, item no. 7: self-expanding aortic valve having top-down deployment with delivery system for tavr, item no. 8: balloon-expanding aortic valve with delivery system for tavr, item no. 9: special balloon-expanding aortic valve with delivery system for tavr, item no. 10: special balloon-expanding aortic valve with delivery system for tavr with octogonal cell structure, item no. 11: special balloon-expanding, trileafletbovine pericrdial tissue valve with delivery system for tavr, item no. 12: special balloon-expanding, trileafletresilia technology bovine pericrdial tissue valve with delivery system for tavr, item no 13: large introducer sheaths for vascular access: 10 18 fr size, item no 14: large lumen introducer sheaths with guidewire for vascular access: 10 18 fr size, item no 15: extra-large lumen introducer sheaths for vascular access: 20 24 fr size, item no 16: extra-large lumen introducer sheaths with guidewire for vascular access: 20 24 fr size, item no 17: introducer/guiding cross-over sheath for contralateral vascular access, item no 18: amplatz support, stainless steel guide wire for structural heart and vascular interventions, item no 19: extra-stiff, stainless steel guide wire for structural heart and vascular interventions, item no 20: extra-stiff, pre-shaped, 260 cm long, stainless steel guide wire dedicated for tavr, item no 21: extra-stiff, pre-shaped, 275 cm long, stainless-steel guide wire dedicated for tavr, item no. 22: percutaneous transluminal valvuloplasty balloon for valve interventions, item no. 23: special percutaneous transluminal valvuloplasty balloon for valve interventions, item no. 24: special percutaneous transluminal valvuloplasty non-compliant balloon for valve interventions, item no. 25: special percutaneous transluminal aortic valvuloplasty balloon catheter for tavr, item no. 26: special compliant balloon catheter for temporary occlusion of large vessels, item no. 27: intravascular retriever microsnare: very small diameter (2 mm) ( g