Get complete information related to latest Ejector Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ejector Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ejector Spares Tenders.
Tender For urgent work at kagdi pickup weir during flood season for the year 2025 - unskilled beldar/ coolie / chowkidar / water man / earth- dresser - unskilled beldar/ coolie / chowkidar / water man / earth- dresser, providing and filling/ replacing hydraulic oil of approved quality up to the required gauge level including cost of all materials, machinery, labour etc. complete., supplying of well stitched earth filled bags of capacity, weigh not less than 40 kg per bag at site etc. complete. plastic bag, empty bag of 50 kg capacity in good condition plastic / polythene, cost of diesel, painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work, hydraulic excavator/ loader like jcb/ poclain, hitachi etc. with all accessories (for actual site working, idle period) having bucket capacity above 0.40 & upto 0.75 cum without gst/ profit, p/laying isi marked p.v.c. insulated submersible cable confirming to(is:694) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.90 % purity copper, stranding in acc. to is:8130/iec 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation pvc type a/c/d , flame retardant as per is 10810-53, better amperage rating as per is:3961 part 5, existing pipe / open trench / cable tray / on surface including making connection etc. as required. for additional technical parameters of product / work refer annexure a attached with this bsr - 6.0 sq.mm 3 core flat / round, p & f of direct on line (dol) / star - delta starter as per iec type-2 co-ordination chart of oem in existing panel with circuit breaker having inbuilt overload protection or separate thermal overload relay , short circuit, phase loss protection, suitable contactors, including wiring between switchgears, indicating lamps for r,y,b,on,off, push button for on, off, volt meter, ammeter, selector switch for local/remote, auto/manual/off operation. cast resin cts, provision for potential free contacts making connection, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . direct on line (dol) starter with following motor rating - motor rating 4.0 kw
Tender For oandmof 6.7 mld .. stp at madgaon..raw sewage ps at navelim for a period of 3 years inclu. cost of material, recti. of def., replac.of damaged, def. parts of the machinery, equip. ..cost of lubricants, oil, maint. aesthetic view of the premises..tidy
Tender For om of 1.35 mld cap stp at gmc, bambolim for a period of 5 yrs incl. cost of material, rect. of defects, replac. of damaged, defective parts of the machinery, equip incl. cost of lub., oil, ...tidy..engineer incharge.
Tender For corrigendum : custom bid for services - rpnc252027 support service for swing extruder vfd installation-shifting, foundation and installation of power transformer- 1. the power transformer is to be installed by construction of new transformer foundation, dismantling/modification of surface, providing chain link fencing on all other 4 sides, cleaning and refurbishment of bay area is in the scope of contractor only. all necessary manpower, tools & tackles, shifting machinery like hydra/crane etc shall be in the scope of contractor only. 2. shifting of power transformer of 7.2 mva onan from store to site, loading-unloading, erection, site storage are in scope of contractor. 3. the basic data sheet and ga drawing of the proposed transformer is attached in scope only. 4. the bidder if required must construct bay width, height and fire walls as per relevant is/iec/oisd standards and site conditions such that adequate clearances for maintenance shall be maintained. bidder to submit the plot plan of equipment layout of transformer layout along with the bid. the bidder shall carryout the site visit for assessment of the available installation space. the total length of the transformer bay should be such that the radiator can be accommodated on either side of transformer tank in the specified bay width. 5. all necessary earth pit provisions, & fire barriers/wall modifications, provision of new hvws water sprinklerbased firefighting system having suitable capacity for protection against the fire & explosion as per the design of supplied transformer and applicable standards & direction of eic. provision of all necessary fire protection system for transformers shall be in the scope of lstk contractor. 6. construction of oil drain facility of transformer as per is standard and hookup with existing burn oil pit. 7. the erection to be certified by contractor as per its recommended procedures which is to be submitted prior to erection. qap for erection and site commissioning shall also to be endorsed by contractor. 8. all kind of lifting, rigging work for loading-unloading, erection work including supply of hydra/ cranes, lifting rigging materials, manpower, tools and tackles as required are in scope of contractor. 9. all kind of skilled, semi-skilled, unskilled manpower as per itc of transformer requirement will be in the scope of contractor. 10. erection includes entire vacuum by proper capacity of vacuum pump, for not less than 48 hours, or more if required as per the instruction of engineer in charge. 11. first filling up of the transformer oil at site, its filtration, site testing oil sample, any refiltration required during final commissioning shall be in the scope of contractor including all tools, tackles and including oil filtration machines. oil may be supplied in drums, which should be properly sealed during transportation and storage. seal shall be verified and opened in front of iocl representative before filling in transformer. contractor should have enough storage capacity for handling oil. filling the oil from drums to the transformer through suitable capacity of high-quality filter machine and filtration of the same to get desired bdv &ppm as specified by engineer in charge and transformer manual. 12. contractor must replace all the gaskets by new ones if required by engineer in charge. 13. the contractor shall arrange nitrogen cylinder required at site for above work. 14. contractor must repaint the transformer tank with two coats of anti-rusting good finish ltbs grey shade 631 of is:5 by spray painting if required and as per the direction of engineer in charge..
Tender For supply of lubricants for heavy machinery and vehicles d d - servo super 20w40 mg 20l iocl original isi mark , servo gear hp90 20 litre bucket iocl original isi mark , servo transfluide a 10x1litre iocl original isi mark , servo cool plus 20x1litre iocl original isi mark , ioc clearblue 20l iocl original isi mark , servo premium sf4 15w40 210 litre barrel iocl original isi mark , servo hydraulic oil 68 iocl original isi mark , servo grease mp3 of 01 barrel iocl original isi mark
Tender For supply of spare parts for toro machinery at jammu tawi golf course, sidhra. f.y. 2025-26 (under capex) - green mower gr-1000, blade reel asm part no 132-7313, bed knife low cut part no 93-4264, pulley, counter shaft part no 65-8910, belt-v matched set part no 92-9218, control clutch cable part no 130-0107, backlapping 120 g (25 lb), b. compound 80 g (25 lb), screw bed knife part no 119-4151, grass shield part no 112-9471, belt part no 65-9080, grounds master 360, mount-motor part no 107-2289, tire part no 115-0132, washer thrust part no 100-2508, roller deck part no 93-4803, deck roller part no 36-1740, roller part no 68-6710, roller scalp-anti part no 106-03299, bushing flange part no 114-5680, oil seal part no 253-154, blade high flow part no 110-0622-03, spindle part no 117-9234, spindle part no 117-9233, seal kit part no 120-2557, gasket-cover, head part no 105-3712, engine oil filter part no 108-3841, seal kit part no 112-0199, seal kit part no 112-6353, pump housing seal kit part no 107-0853, cover (asm) part no 104-0497, seal kit part no 130-8357, seal kit part no 107-9368, ignition switch part no 121-5159, seal part no 117-9247, v- belt part no 115-0123, pulley-fan part no 99-3453, fuse 2amp., machine service, services, fairway mower 5510, bed knife part no 110-4084, screw bed knife part no 119-4151, element filter part no 94-2621, oil filter part no 108-3841, fuel filter part no 98-7612, filter spin on part no 110-9049
Tender For comprehensive mtc (routine and preventive with parts including consumables items such as gas, oil, filters) and break down mtc.of high and low side of the ac plant comprising of all machinery at gyane o.t 1st floor in civil hospital, sector-22, chd