Get complete information related to latest Elastomer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Elastomer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Elastomer Tenders.
Tender For corrigendum : providing of custom bid for services - hiring the services of three (03) sets of well servicing unit consisting of coiled tubing unit (ctu), nitrogen pumping unit (npu), fluid pumping unit (fpu) with heating facility and other related accessories
Tender For corrigendum : purchase of recovery and rejuvenation lab equipment - cryotherapy chamber (pac), whole body cryo therapy chamber that runs completely on electricity without need of liquid nitrogen low temperatures within the range: -130 to -140 degree celsius. multiple treatment options electric mechanical lift system ensures user s head is outside the chamber to preventexposure to cryogenic temperatures. real-time skin temperature monitoring using ir tech sensors ensuring safe and controlledcooling. smart software that manages the treatment processesthroughout each session.simple quick plug-and-play set up without requiring specialized ventilation. large uhd touchscreen for easy operation andcontrol. at least 3 media monitors for displaying mediacontent. hifi speakers for audio entertainment and ambientaudio.work on normal indian 220v at 16a or less
Tender For corrigendum : purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touch screen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopa
Tender For bid to ras corrigendum : supply of gas acetylene dissolved note: gas cylinder to be painted at ground with maroon colour as per specn. i , nitrogen gas having purity of 99.5% with grade n2.5 to specification is: -1747-2023 along with nitrog , gas oxygen. note: gas cylinder to be painted at ground with black colour as per specn. is: 4379-1981(g
Tender For corrigendum : supply of weldcut two stage two gauge nitrogen regulator ( outlet pressure 10 bar) model 42 series , weldcut spare repair kit 423441 of model 42 series , weldcut single stage two gauge nitrogen reg bni 6100 high pressure , weldcut spare repair kit 6031 6000 series
Tender For corrigendum : supply of supply of fertilizer urea containing 46 percent nitrogen to banarhat tea estate at dooars region wb , supply of fertilizer urea containing 46 percent nitrogen to karballa tea estate at dooars region wb , supply of fertilizer urea containing 46 percent nitrogen to new dooars tea estate at dooars region wb , supply of fertilizer urea containing 46 percent nitrogen to choonabhutti tea estate at dooars region wb , supply of fertilizer urea containing 46 percent nitrogen to mim tea estate at darjeeling region wb
Tender For corrigendum : supply of set of standard calibration gas canister for dga consisting of (1) methane, ethane, ethylene, acetylene, hydrogen, co & co2 each 100 ppm and nitrogen balance, qty- 01 no. (2) methane, ethane, ethylene, acetylene, hydrogen, co & co2 each 500 ppm and nitrogen balance, qty- 01 no. (3) methane, ethane, ethylene, acetylene, hydrogen each 1000 ppm, co & co2 each 5000 ppm and nitrogen balance qty- 01 no. with pressure gauge, septum and knob arrangement to draw sample directly from canister using gc syringe. preparation tolerance plus (or) minus20 percentage & shelf life 12 months. canister capacity 0.5 litres, filling pressure 20 kg/sq.cm with test certificate and suitable septum as spares.