Get complete information related to latest Electric Furnace Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electric Furnace Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electric Furnace Tenders.
Tender For corrigendum : green polycarbonate face shield shed 5, size 9 x 14 1/2 inch, thickness 2mm as per standard en 166 with aluminium carrier for visor fitting with helmet. material : polycarbonate, design : cylindrical, size : 9 x 14 1/2, thickness : 2 mm, green shade 5 , visor moulded polycarbonate visor lens filter protects eyes from infrared rays, protection against high-speed impact (level b), splash of liquids and extreme temperature 99.9 % uv protection. best optical quality (highest ranking at the tests of spherical refractive power, astigmatic refractive power, prismatic refractive power and light diffusion). best use for furnace observation, welding, brazing, cutting etc. confirm to standard: en166: 2001, ce & firm has to be submitted related certificate for confirming the en standarden166: 2001, ce from any govt. approved / nabl lab. al3 carrier - aluminium construction, simple to connect to safety helmet via sprint tensioner system & does not interfere with use of helmet mounted ear defenders. preferable to be used in heat zone. firm has to get prior approval of sample before bulk supply. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For providing of customized amc/cmc for pre-owned products - repair of 02nos. electric cremetorium and 01 venturi scrubber at shankarghat and comprehensive maintenance of 02 nos. electricfurnace at shankar ghat and 01 nos. venturi scrubber at shankar ghat and 01 nos. venturi scrubber at daraganj electric crematorium for 03 years
Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r
Tender For bogie frame to drg. no. (a) icf/mrvc/d-0-3-001, alt "n", col-ii (or) (b) icf/mrvc/d/bt-0-3-001, alt "c", col -ii along with damper fixing bracket to drg. no. (339)ac/dcemu/d6-0-1-602,col.i - 4 nos andbolt complete to drg. no. emu/m/3ph-0-2-002, alt "c", col.i - 16 sets bogie frame to be supplied without nylon bushes where ever applicable and shall confirm to rdso/specn.c-9202, rev-2 or latest. the firm shall fulfil the requiremnt as per icf/md/specn/147, issue status 01, rev-02 with amendment no- 02. special condition : - suppliers commitment will be there to supply as per drawing -(a) ( for dash pot arrangement ) or as per new drawing - (b) ( for adoption of conical spring ). - one month notice willbe given to vendor whether he has to supply as per drawing - (a) or drawing - (b). -rate quoted will be applicable to both drawing - (a) and drawing - (b) . i) paint scheme shall be as per drawing. ii) qap to format icf/ims/md/f-31 shall be prepared along with relevant documents and kept ready for developmental/educational order. iii)firm should supply bogie frame along with the dimensional report, stress relieving report and radiography films. iv) firm should have induction/electricfurnace for stress relieving of bogie frame. v) prototype inspection is applicable only for first time of developmental/educational order. vi) stage inspection to be done as below. (a) raw material stage 1. ensure the raw material used using portable spectrometer machining stage 1. dimensional checks 2. edge preparations (b)welding stage 1. weld parameter to be checked and recorded. (c) surface preparation and painting stage. 1. short/sand blast to the requirements. 2. painting process as per the specification. 3. final product inspection. [ warrantyperiod: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : bogie frame to drg. no. (a) icf/mrvc/d-0-3-001, alt "n", col-ii (or) (b) icf/mrvc/d/bt-0-3-001, alt "c", col -ii along with damper fixing bracket to drg. no. (339)ac/dcemu/d6-0-1-602,col.i - 4 nos andbolt complete to drg. no. emu/m/3ph-0-2-002, alt "c", col.i - 16 sets bogie frame to be supplied without nylon bushes where ever applicable and shall confirm to rdso/specn.c-9202, rev-2 or latest. the firm shall fulfil the requiremnt as per icf/md/specn/147, issue status 01, rev-02 with amendment no- 02. special condition : - suppliers commitment will be there to supply as per drawing -(a) ( for dash pot arrangement ) or as per new drawing - (b) ( for adoption of conical spring ). - one month notice willbe given to vendor whether he has to supply as per drawing - (a) or drawing - (b). -rate quoted will be applicable to both drawing - (a) and drawing - (b) . i) paint scheme shall be as per drawing. ii) qap to format icf/ims/md/f-31 shall be prepared along with relevant documents and kept ready for developmental/educational order. iii)firm should supply bogie frame along with the dimensional report, stress relieving report and radiography films. iv) firm should have induction/electricfurnace for stress relieving of bogie frame. v) prototype inspection is applicable only for first time of developmental/educational order. vi) stage inspection to be done as below. (a) raw material stage 1. ensure the raw material used using portable spectrometer machining stage 1. dimensional checks 2. edge preparations (b)welding stage 1. weld parameter to be checked and recorded. (c) surface preparation and painting stage. 1. short/sand blast to the requirements. 2. painting process as per the specification. 3. final product inspection. [ warrantyperiod: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]