Tender For repair/replacement of capacitor bank, sign board, fencing cable duct cover, route indicator and miscellaneous work at various sub station/installation at af stn gwalior.
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electriccable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For providing of facility management services - lumpsum based - commercial; electrical cablelaying and associated works; consumables to be provided by service provider (inclusive in contract cost)
Tender For procurement of materials for repair of various components used in the fixing of light poles installed across of the failure different wards within municipal area - 61.13 p/l of double wall corrugated hdpe pipe confirming to is 16205 p-24, stiffness class 750 n, externally corrugated and having smooth surface inside with hdpe coupler, elbow, tee at required depth below the ground for layingcable of following nominal outer dia. mfr test report from nabl accrediated is to be submitted. (excavation of earth & back filling with compaction is to be paid extra) all as per pre approved by engineer in-charge.. for additional technical parameters of products/ work, refer annexure "a" attached with this bsr 50mm dia. , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured copper cable confirming to is:1554 p-i / is:7098 p -i of 1.1 kv with electrolytic grade copper made of copper rods confirming to is 613-1964, of purity >99.7%, inner/outer sheath confirming to is:5831 in existing rcc/hume/stoneware / pvc pipe/open duct/cable trench/cable tray (with cable tie) including testing etc. as required of following size. oem must have it's own in house nabl accrediated laboratory for testing procedure as per is:10810 for additional technical parameters of product / work refer annexure 'a' attached with this bsr 3 core , supplying and making one end termination with nickel plated heavy duty brass single compression gland (as per is 12943-1990)) sibg type consisting of check nut, gland body, metal washer(3 nos.), outer seal rubber ring, compression nut, heavy duty aluminium lugs (as per is 8309-1993) duly crimped with crimping tool, pvc tape as per is 8337-1976 of following size of pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in-charge. for additional technical parameters of products/work, refer annexure "a" attached with this bsr 4 x 10.0 sq.mm pvc tape roll , supply and fixing of following lt supporting accessories with nut bolt & clamps made out as per standard discom's specifications with two coats of red oxide and two coats of aluminium paint etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure "a' attached with this bsr type a lt connector for aerial bunched cable each 73.00
Tender For supply of signage control unit tower server type poweredge. , streaming encoder with audio open standard avoip 4k , management work station , perpetual license , server bundle license minimum 50 user , professional display unit 43 inch , professional display unit 55 inch , 9u rack 600x500 , 24 port unloaded patch panel , cable manager , keystone jack , 1 mtr patch cord , cat6 cable box 305 meter , 12f mm armoured fiber om3 cable , 12 port loaded mm liu lc om3 , lc lc mm duplex patch cord om3 , sfp mm module lc duplex om3 , 6f sm armoured fiber , 6f loaded liu , lc lc sm duplex patch cord , sm duplex sfp lc module , pigtel for fibre termination , 24 port gigabit manageable switch with 4 sfp modules rack mount , 8 port gigabit manageable switch with 2 sfp modules rack mount , 4mm 3core power cable or wire , 25mm precision conduit pipe , 3 slot modular board , 40 amp 2 poll mcb , 2 poll mcb box , 1.5 inch casing patti , fiber termination work , termination of keystone jack, cable identification, cable bundling with cable tie, rack dressing and cable numbering with ferrul and crimping as per actual , trenching for layingcables per metre , rack installation , installation charge for cat6 cable, fiber cable, electriccablelaying in conduit casing caping with required saddle box, 35x8 screw box, pvc rawal plug packet, wire tape and commissioning of system ) /bid number : gem/2026/b/7584227 * /dated: 27-05-2026 & & / bid document 1 / 31