Get complete information related to latest Electric Debeaker Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electric Debeaker Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electric Debeaker Tenders.
Tender For shifting of electro pneumatic pressurized flushing system (eppfs) cylinder ( including pneumatic & electric connections etc.) from underslung to onboard in lhb coaches at be, ddn & ynrk depots
Tender For supply of overhauling kit for isolating cock (fp) (ii30399 or ii107853) for 3- phase electric locomotives with ccb-2 system to m/s kbil kit part no. xki/ kit/02485 ( each kit consists of 11 items in 12 nos. as per annex.) [ warranty period: 30 months after the date of delivery ] ]
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For repairs maintenance of electrical and mechanical equipments high mast light search lights and other miscellaneous items at cad pulgaon - disconnecting and taking down existing unserviceable street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. repairing/replacing unserviceable parts re-fixing the same on pole/wall after testing and removal of carbon from line jumpers/tightening of jumper/alignment of fitting defective street light/security light/flood lights fitting/led light from electric pole complete all as directed by eic. note: spare parts and accessories such as led driver, and connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included in this item., supply only led street light driver for 45 watts led street light as per make given all as specified and directed by eic., supply only led street light driver for 60 watts led street light/ flood light type as per make given all as specified and directed by eic., supply only led street light driver for 100 watts led street light/ flood light type as per make given all as specified and directed by eic., supply and fix in repair led streetlight of 45 watt comprises of pressure die cast aluminium housing & having system efficiency>123 lumens/watt i.e 5570 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k,pf>0.9,driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account. 3.the complete fitting along with led module, driver, surge protection device and all associated accessories shall be covered under 05 (five) years comprehensive warranty by the contractor from the date of invoice.make : philips/ wipro/crompton, supply and fix in repair led streetlight of 60 watt comprises of pressure die cast aluminium housing & having system efficiency>110 lumens/watt i.e 6670 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k, pf>0.9, driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic. note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account.3. the complete fitting along with led module, driver, surge protection device and all as
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For repair to water supply distribution network including disinfection of water supply at various pump house and repair to various submersible pump, booster electric control system at af station chandigarh under ge (af) chandigarh
Tender For repairing replacement of internal wiring fitting and fixture and various type of led fitting and connected earthing items at domestic area at af stn naliya - materila and labour for point wiring with 1.5 sq mm frlsh single core pvc insulated unsheathed 1100 v grade with multistranded copper conductor drawn through pvc casing and capping with all accessories fixed to wall froofs ceiling etc and incl provision of 1.5 sq mm pvc insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly including pvc box isi marked of suitable size for mounting the switches, socket outlets, fan regulators etc., complete all as specified and directed for following:- one light/fan point controlled by one switch. one socket 3 pin outlet 5 amp on independent board. one light point controlled by two 2-way switches. one 3 pin socket outlet 5 amp on the same board with other switches. one bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size. all as per serial item number 2.00 here-in-before but with copper conductor cable of 2.5 sqmm size for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm copper cable as earth continuity conductor. supply and fix in replacment of switch piano flush type single pole one way 5 amp, complete all as specified and directed. supply only socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed. supply only socket outlet multipurpose 213 pin 5 amps flush button type with universal box in polycarbonate complete all as specified and directed. supply only switch socket multipurpose 2 in 1,5 and 15 amps complete all as specified and directed. supply only ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed. supply only switch bell push, flush type 5 amp. supply only electric bell ding-dong ac 230 volt sp with brass screws and cup washers all as specified and directed. pa supply only hylem sheet 3 mm thick size 9" x 11" including cutting of switch,socket complete all as specified supply only hylem sheet 3 mm thick size 8" x 5" including cutting of switch,socket complete all as specified supply only mcb single pole and neutral 32-63 amps, 240 volts, complete all as specified and directed. all as per item ser no 60 above but with two run of single core 6 sq mm and one run of 6 sq mm frlsh as earth wire s&f in replacement of 9 watt led bolard lights 4300/6500 k in rectangular shaped victorian design with opal acrylic diffuser and ip 65 protection,including pcc work for mounting the fittings with suitable size of nut, bolts and connection with two core copper cable all as specified and as directed. make bajaj, havells, crompton. m&l for repair / maint of wooden/steel boards for electrical db of any type and size including replacement of doors as per site requirement, hinges, handle and locking arrangement with necessary welding works, wooden works to make good the wooden / steel boards including painting with synthetic enamel paint of one coat all etc complete. the quoted shall be inclusive of replacement of wooden doors! steel doors/hinges! locking system/welding work required for repair/fixing of new doors etc complete pac s&f in replacement of 36w led recessed 2x2 luminaire 6500k fixed in the existing ceiling/roofs white powder coated crca housing with led seanless front frame with flat white transmission acrylic cover and necessary connection with twin core copper cable of suitable size in kutch auditorium with ceiling height of more than 20 feet including necessary arrangement for scaffolding ladder for replacement of ceiling lights all as specified and as directed. note: the quoted rates are inclusive of necessary safety arrangements iscaffolding/ladder etc complete all as specified and directed