Tender For corrigendum : supply of dynamometer load range 0 4 kg , calibration of dynamometer load range 0 5 kg , calibration of dynamometer load range 5 15 kg , calibration of dynamometer load range 15 55 kg , calibration of dynamometer load range 0 500 kg , calibration of dynamometer load range 0 200 kg , calibration of dynamometer load range 0 50 kg , calibration of dynamometer load range 0 150 kg , calibration of dynamometer load range 0 5000 gram , calibration of dynamometer load range 0 80 kg , calibration of dynamometer load range 0 2 ton , calibration of dynamometer load range 0 5 ton , calibration of dynamometer load range 0 300 lbs , calibration of dynamometer load range 0 10 ton , calibration of aircraft weighing kit load range 5 ton , calibration of aircraft weighing kit load range 10 ton , calibration of universal testing machine load range 0 500 kg , calibration of universal testing machine load range 0 1000 kg , calibration of universal testing machine load range 0 3 ton , calibration of universal testing machine load range 0 5 ton , calibration of universal testing machine load range 0 10 ton , calibration of universal testing machine load range 0 20 ton , calibration of universal testing machine load range 0 50 ton , calibration of master dynamometer load range 0 1 kn , calibration of master dynamometer load range 0 5 kn , calibration of master dynamometer load range 0 10 kn , calibration of master dynamometer load range 0 50 kn , calibration of master dynamometer load range 0 100 kn , calibration of standardizing box load range 0 200 kn , calibration of traction power tester load range 0 500 kn , calibration of load cell load range 0 25 kn , calibration of new dynamometer load range 0 5 ton , calibration of new dynamometer load range 0 25 ton , calibration of dynamometer load range 0 5000 gm , calibration of traction power testerload range 0 500 kn
Tender For corrigendum : rate contracts for radiology interventional procedures supply for the year 2026-2027 & 2027-2028 - peripheral self expanding stent, 6 fr, otw, nitinol based, open/ closed cell/ hybrid design, with distal and proximal markers made of tantalum/ gold (for better visibility), should be 6 fr compatible. should be electropolished for better visualization under fluoroscopy. should have good radial strength. shaft length should be maximum 80 cm. - for biliary use., 250, 0.035", 4, diameter: 10 to 20 mm, length: 40 to 200 mm, peripheral self expanding stent, -, otw, nitinol based, encapsulated between 2 layers of eptfe, carbon coating in inner lumen. should have flared ends., 5, 0.035", 8, diameter: 5 to 10 mm, length: 10 to 60 mm, peripheral balloon expandable stent, -, otw, cocr/ stainless steel based, encapsulated between 2 layers of eptfe., 5, 0.035", 12, diameter: 4 to 8 mm, length: 10 to 40 mm, peripheral balloon expandable stent, -, stent for dedicated use in trans jugular intrahepatic porto systemic shunt. should have both covered and uncovered parts in 1 stent., 1, 0.035", 16, diameter: 4 to 8 mm, length: 10 to 40 mm, coronary stent graft, -, otw, nitinol based, fully covered, percutaneously retrievable (via ptbd access), with long radioopaque string, 1, 0.014" / 0.018", 20, all sizes, ureteric stent, -, should be made from pu material. should have 2 pigtail loops., 50, 0.035", 24, 260 cm, amplatz guide wire, -, amplatz super stiff guide wire j tip/ straight tip / angled tip, 100, 0.035", 28, 150 cm, angiographic guide wire, -, angiographic guide wire, hydrophilic coated, angled tip, 25, 0.035", 32, 260 cm, angiographic guide wire, -, hybrid angiographic guide wire, shoould be kink resistant, should come with distal 25 cm atraumatic hydrophilic coated tip, should have nitinol core, angled tip, 5, 0.014", 36, 150 cm, angiographic guide wire, -, angiographic guide wire with long tapered tip load of 6 gm, 5, 0.018", 40, diameter: 3 to 10 mm, legth: 40 to 300 mm, peripheral semi compliant balloon, -, otw, with low entry profile, markers at proximal and distal tip of balloon, 5, 0.035", 44, diameter: 12 to 26 mm, legth: 20 to 60 mm, peripheral non compliant balloon, -, otw, non compliant balloon, should have rbp of at least 18 atm, 5, 0.035", 48, diameter: 2 to 6 mm, legth: 10 to 40 mm, coronary noncompliant balloon, -, soft, compliant, with proximal and distal radio opaque markers, 5
Tender For supply, fitment and installation of 02 nos. load cell 30 ton along with alignment of weigh bridge. [ warranty period: 30 months after the date of delivery ] ]
Tender For bid to ras bid to ras providing of testing service for on-board /commissioned equipment/ instrument related to plant - ndt; carbonation test, crack width measurement in reinforcement concrete structures, deflection measurement data (load test), half cell potential difference test, reb..
Tender For load cell tension and compression range 50 kn , load cell tension and compression range 100 kn , displacement transducer (0 - 200 mm) , load cell tension and compression range 5000 n , load cell tension and compression 10000 n , load cell tension and compression range 20000 n