Web Analytics Made Easy - StatCounter

Electric Line Repair Tenders

Get complete information related to latest Electric Line Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electric Line Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electric Line Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40071789 Due date: 19 May, 202519 May, 2025 NA
Tender For providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above supplied stab

State Government

CTN :40054981 Due date: 28 Apr, 202528 Apr, 2025 69.3 Thousand
Tender For corrigendum : estt for conductor augmentation of 11 kv rohilpura and 11 kv devpur feeder double circuit line form sironj s/s to rohilpura under sironj (t) dc

Central Government/Public Sector

CTN :40098318 Due date: 07 May, 202507 May, 2025 99.82 Lacs
Tender For supply of annual operation and maintenance of electrical and mechanical works at rupsi airport - operation and maintenance of electrical and mechanical installations , job contract for operation and day to day maintenance services of airport systems equipments , execution of item of schedule of rates cpwd dsr 2022 as and when required , testing of transformer oil sample including conducting bdv test and submission of test report etc complete as required , filtration of transformer oil of 630 kva transformer , supply of transformer oil conforming to is 335 1983 , servicing and checking of lt air circuit breaker , servicing and checking of ht vacuum circuit breaker , calibration and testing of relays at ht panel , calibration and testing of following relays at lt and synchronizing panel , scrubbing, cleaning the existing surface of cubicle panel, feeder pillars and painting , lettering of maximum 2 inch size alphabetic or numerical , cleaning the surface of ms chequered plates , supply and replacement of silica gel in breather of existing 630 kva transformer etc. complete as required , lifting and lowering of 10 hp borewell submersible motor pump set , servicing and complete overhauling of 10 hp borewell submersible motor pump set , decoration of terminal building and canopy of rupsi airport , supply and replacement of defective smoke detectors , supply and replacement of defective manual call point , maintenance and service of addressable two or one loop honeywell make fire alarm systems , supply of convertor or driver suitable for philips make 20 w downlight types led luminaires or fittings , supply of convertor or driver suitable for osram make 120w types of led luminaires or fittings , supply of convertor or driver suitable for havells make 18 or 20 w downlight of led luminaires or fittings , supply of convertor or driver suitable for wipro make 36w 2ftx2ft recess mounted of led luminaires or fittings , supply of 1000w 240v lamp suitable for aerodrome beacon , supply of aerodrome beacon , calibration of clinometer , supply of minimum 10 meter high wheel driven telescopic ladder , supply of reflector , supply of 2c x 4 sq mm. secondary lead with plug , supply of b connector or four way porcelain terminal , supply of 5 kv grade 50 hz ac isolating transformer , supply of two pin halogen lamp holder suitable for 200 watt , supply of 5 w screw cap led lamp , supply of wind sock cloth , supply and replacement of led flood light , supply and replacement of obstruction light of wind direction indicator , supply and replacement of 180 ah 12 v lead acid battery , supply and replacement of 100 ah 12 v lead acid battery , supply of automaic electric hand drier , servicing, checking repairing overhauling and testing of crompton make 630 kva transformer

State Government

CTN :40084418 Due date: 05 May, 202505 May, 2025 32.59 Lacs
Tender For work of 1).shifting & re-routing of ht, lt line and dtc at bijapur circle 2). shifting of 11kv f6 shakapur njynfeeder and f7 malla k feeder ht line at basaveshwar circle 3). shifting of 11kv f12 verchnalli njy feeder and f1 kasar bosga ip double circuit feeder ht line at basaveshwar circle in jewargi town section of o&m sub-division, gescom, jewargi under deposit contribution work (kkrdb) on total turnkey basis

CTN :40045988 Due date: 13 May, 202513 May, 2025 2.04 Crore
Tender For supply ,erection, testing and commissioning works for interconnection arrangement (tie feeder) of 6.6kv cubical switchgear panels incorporating vcb( vacuum circuit breaker rating- 12kv, 3150amp.,isc- 40ka at the rate 1sec.) for phase -i to phase- i

CTN :40052769 Due date: 29 Apr, 202529 Apr, 2025 2.04 Crore
Tender For supply ,erection, testing and commissioning works for interconnection arrangement (tie feeder) of 6.6kv cubical switchgear panels incorporating vcb( vacuum circuit breaker rating:- 12kv, 3150amp.,isc:- 40ka @1sec.) for phase i to phase ii through

corporations/Associations/Others

CTN :40073722 Due date: 26 Apr, 202526 Apr, 2025 1.64 Crore
Tender For estimate for installation of tail less unit at single lt circuit of 250, 400 & 630 kva dt installed at various 11 kv feeder emanating from different 33/11 kv substation under 2024-25 business plan work in eudd-viii gzb for protection of dt from lt fault.

corporations/Associations/Others

CTN :40073756 Due date: 26 Apr, 202526 Apr, 2025 1.60 Crore
Tender For estimate for installation of tail less unit at lt circuit of 250, 400 & 630 kva dt installed at various 11 kv feeder emanating from different 33/11 kv substation under 2024-25 business plan work in eudd-vi gzb for protection of dt from lt fault.

corporations/Associations/Others

CTN :40073784 Due date: 26 Apr, 202526 Apr, 2025 1.21 Crore
Tender For estimate for installation of tail less unit at lt circuit of 250, 400 & 630 kva dt installed at various 11 kv feeder emanating from different 33/11 kv substation under 2024-25 business plan work in eudd-ii gzb for protection of dt from lt fault.

State Government

CTN :40053033 Due date: 23 Apr, 202523 Apr, 2025 NA
Tender For estimate for bifiucation of 33kv overloaded solipur feeder emanating fiom 132/33kv ghanpur eht ss with erection of 4.6km 33kv interlinking line to 33kv ghanpur feeder emanating from the same eht ss which involves stringing of 4.6km oh line (100 sqmm auau{c) over existing and now proposed i i mtr pscc poles from near ghanpur ss to near manajipet stage as a 2nd circuit to the existing 33kv solipur feeder and laying of 60 mtrs of 33kv 3x400 sqmm. xlpe ug cable(double run)in ghanapur mandal of wanaparrhy sub division in operation division wanaparthy of operation circle wanaparthy under t&d improvement to original works. wbs no t- 243040-06-01-01-001. (lst extension)
 Loading, Please wait...

Connect us via What's Up