Get complete information related to latest Electric Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electric Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electric Meter Tenders.
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For corrigendum : provn of smart electricmeters including annual maintenance contract of meters at air force stn jamnagar, jaisalmer,bhuj,chiloda, madh island, jaipur, mumbai and uttarlai
Tender For corrigendum : inclusion of existing smart meters in the scheme and replacement of existing energy meters with smart electricmeters at mount abu mil stn and udaipur mil stn
Tender For supply, erection, testing and commissioning of ct meter of standard make with cubical meter box as per hvpnl specifications including 3 phase electrical meter 100/5 of standard make approved by hvpnl including ct/pt of suitable rating complete in all respect as per directions of engineer-in-charge ,mccb ,distribution boards, mcb`s, rccb`s, change over etc. 8.1. supply, installation, testing and commissioning four pole on load manual change over switch in ss enclosure of following ratings 63 amp 415 volts
Tender For corrigendum : maintenance of electrical installation and fans, repair and maintenance of p/set in cgs colony, kane nagar, mumbai-400037.sub head: cleaning and restructuring of existing cable trench in electricmeter cabin and strenthening the safety measures as required in navjeevan and navchetna building in sector 5 and 3, kane nagar antop hill, mumbai-37
Tender For supply of led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , led luminaire for floodlight conforming to is 10322 (part 5/section 5) (v3) (under bis scheme - ii) (q2) , pvc insulated copper cable single core and multi core circular sheathed with rigid conductor (v2) isi marked to is 694 (q2) , pvc insulated copper cord single core and multi core circular sheathed with flexible conductor (v2) isi marked to is 694 (q2) , capacitors for electric fan motors as per is 1709 (v2) (q3) , electricmeter single phase ac digital smart meter 0 to 30 amp , lugs alumn 300 sqmm , lugs alumn 240 sqmm , lugs alumn 95 sqmm , lugs alumn 185 sqmm , lugs alumn 150 sqmm , lugs alumn 70 sqmm , lugs alumn 120 sqmm , lugs alumn 35 sqmm , lugs alumn 16 sqmm , lugs alumn 25 sqmm , lugs alumn 50 sqmm , jumper valve for bib obliquestop cock off sizes , lugs alumn 10 sqmm