Get complete information related to latest Electric Pole Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electric Pole Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electric Pole Tenders.
Tender For corrigendum : repair and maintenance work of foot path and light arrangements,eb board,play materials and name board works in tnhb p-iii park at ward no.33 zone -4 in tcmc - eangaging of man power for cleaning weeds and bushes at lawn areas cutting plants and grass including all labour charges etc complete, gardener 5 days 6 nos, mazdoor ist class, engaging of ac electric grass cutter on hire basis including hire charges transport charges and all labour charges etc complete, supply and fixing of childerns play materials including cost and conveyance and fixing and proper alingenement charges etc complete, slider, 2 seater swing, 4 seater see saw, supplying and filling in foundation and basement with river sand in play area in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification., supply and fixing of light pole 4 metre length single bracket pole with base plate (250 x 250 x 6mm)76.10mm od x 3.65mm thick x 4000mm length etc.,completed, supply and fixing of 30w led street light fitting with led on out door fittings including cost and conveyance and fixing charges etc complete, supply and fixing of synthetic moulded compound box for street light with 16 a mcb and connecterincluding cost and conveyance and fixing charges etc complete box-735+16 a mcb sp and neutral -382, supply and fixing of 4 sqmm pvc unsheathed copper cable including cost and conveyance and fixing charges etc complete , supply and laying of 2 x 10 sq.mm pvc armoured ltug cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good sd 194, centering and shuttering charges for all pcc and rcc works using ms steel moulds and soffits strutting with casurina props 10-13 cm dia including cost and conveyance of all materials and including all labour charges etc complete, plain cement concrete 1;2;4 mix using 20 mm hbg iss metal including cost and conveyance of all materials and including all labour charges etc complete, supply and filling of on quarry rubbish 15 cm thick on each layer including cost and conveyance and all labour charges for filling and consolidation charges etc complete, cement concrete 1:5:10 (one cement, five crushed stone sand and ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard speci cation and as directed by the departmental of cers. -mixing by manual means, paving the oor with pre-polished concrete anti-skid tiles (required shape and design) of 20mm thick of approved quality and colour laid in accordance with is 1443 over a cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required cement slurry and mortar plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 kg. / sq.m., curing, etc., complete complying with standard speci cation and as directed by the departmental of cers. (the make and brand of the tiles should be got approved by executive engineer before use on works), supply and fixing of m.s grills with doors and windows with one coat of red oxide with primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification., supply and fixing of stone bench including cost and conveyance and fixing and proper alingenement charges etc complete, supply and delivery of ms kiosk of size 0.75m x 0.45m x 0.75m made up of ms angle of size 50mm x 50mmx 4mm alround covered with 16 gauge ms sheet and kiosk door made up of ms plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements and labour charges etc.,(twad sor 2025-26 unicode wd-m1471 clau
Tender For supply of 2 point 5mfd ceiling fan capacitor , 3m plate make roma , 4m plate make roma , 6m plate make roma , 8m plate make roma , 12m plate make roma , 3m surface type pvc box make roma , 6m surface type pvc box make roma , 8m surface type pvc box make roma , 12m surface type pvc box make roma , 1m blanking platedummy make roma , 3pin 6a socket 2m make legrand , 616a 2in 1 socket 2m make legrand , 3pin 6a socket 2m make roma , 616a 2in 1 socket 2m make roma , 3pin 6a socket 2m make mk , 6a socket 2m make mk , 6 10a switch, 1m make roma , switch mk , switch legrand , 16 20a switch, 1m make mk , 16 20a switch, 1m make roma , 6pin 6a 16a ss combined with shutter and pvc boxmake anchor , 32a single pole c type mcb make legrand , 32a 2p c type mcb make legrand , 32a 3p c type mcb make legrand , 32a 4p c type mcb make legrand , 63a 4p c type mcb make legrand , 32a spn plug industrial socket and cap with metallic enclosure box suitable for ac make legrand , insulation tape , fischer plug suitable for 1 inch drywall screw , fischer plug , screw , 1ft 58w led cool white tube lightmake cromptonsyska equivalent , 2ft 14wled cool white tube light , cool white round led false ceiling light , 12w cool white round led surface mounting light , 18w cool white round led false ceiling light , 15w cool white round led surface light , 18w cool white round led surface light , 1m fan regulator make roma , 1m 4step 04fan regulator make legrand , 2m fan regulator makemk , exhaust ventilating fan makeorient model ventilator dx , telephone instrument , telephone instrument with caller id , 5inch pvc round sheet , thermostat solar water tank , 200w led cool white flood light , 56a 3pin plug top , 15a 3pin plug top , 9inch nylon selflocking cable tie , copper wire , dol starter make l and t bch electric , annealed copper telephone flexible unarmouredcable , aa duracell batteries , distilled water , handheld cardless microphones with 2mics in each and receiver with standard accessories , capacity empty oil barrel suitable for purchasing of diesel , rotary manual hand pump with dual direction , pvc casing pipe , pvc heavy duty conduit pipe , pvc casing heavy duty conduit pipe , mseal 90gm , steel clamp
Tender For supplying electrical materials and repair maintenance services for street lights and electrical works at. grampanchayat somatane - electrical material, supplying and erecting modular type switch6a / 10a ., supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded ., providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles), supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation ., supplying and erecting street light bracket made from 25mm. dia b class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification, supplying,tpmcb 40a to 63a in provided distribution board, providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply., supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse, supplying h.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respectively, 1.25 mm crca sheet metal enclosures with 20a., supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable ., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink ., supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium ., supplying & laying pvc armoured cable 4core 6sq mm, supplying & laying pvc armoured cable 4core 10 sq mm, supplying & laying pvc armoured cable 2core 10 sq mm, supplying & laying pvc armoured cable 4core 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting), supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting), supplying, erecting & marking tpmcb 6 a to 32amp ., supplying, erecting & marking fpmcb 40a to 63a ., supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm., supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm., supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials., supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunk
Tender For providing shifting & installation work of electricpoles from garhbengal to dhourai (rajnandgaon bailadila road 176/60 to 209 = 32.60 km) at district narayanpur (c.g.)
Tender For repairs maintenance of electrical and mechanical equipments high mast light search lights and other miscellaneous items at cad pulgaon - disconnecting and taking down existing unserviceable street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. repairing/replacing unserviceable parts re-fixing the same on pole/wall after testing and removal of carbon from line jumpers/tightening of jumper/alignment of fitting defective street light/security light/flood lights fitting/led light from electricpole complete all as directed by eic. note: spare parts and accessories such as led driver, and connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included in this item., supply only led street light driver for 45 watts led street light as per make given all as specified and directed by eic., supply only led street light driver for 60 watts led street light/ flood light type as per make given all as specified and directed by eic., supply only led street light driver for 100 watts led street light/ flood light type as per make given all as specified and directed by eic., supply and fix in repair led streetlight of 45 watt comprises of pressure die cast aluminium housing & having system efficiency>123 lumens/watt i.e 5570 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k,pf>0.9,driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account. 3.the complete fitting along with led module, driver, surge protection device and all associated accessories shall be covered under 05 (five) years comprehensive warranty by the contractor from the date of invoice.make : philips/ wipro/crompton, supply and fix in repair led streetlight of 60 watt comprises of pressure die cast aluminium housing & having system efficiency>110 lumens/watt i.e 6670 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k, pf>0.9, driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic. note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account.3. the complete fitting along with led module, driver, surge protection device and all as
Tender For repairing replacement of internal wiring fitting and fixture and various type of led fitting and connected earthing items at domestic area at af stn naliya - materila and labour for point wiring with 1.5 sq mm frlsh single core pvc insulated unsheathed 1100 v grade with multistranded copper conductor drawn through pvc casing and capping with all accessories fixed to wall froofs ceiling etc and incl provision of 1.5 sq mm pvc insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly including pvc box isi marked of suitable size for mounting the switches, socket outlets, fan regulators etc., complete all as specified and directed for following:- one light/fan point controlled by one switch. one socket 3 pin outlet 5 amp on independent board. one light point controlled by two 2-way switches. one 3 pin socket outlet 5 amp on the same board with other switches. one bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size. all as per serial item number 2.00 here-in-before but with copper conductor cable of 2.5 sqmm size for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm copper cable as earth continuity conductor. supply and fix in replacment of switch piano flush type single pole one way 5 amp, complete all as specified and directed. supply only socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed. supply only socket outlet multipurpose 213 pin 5 amps flush button type with universal box in polycarbonate complete all as specified and directed. supply only switch socket multipurpose 2 in 1,5 and 15 amps complete all as specified and directed. supply only ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed. supply only switch bell push, flush type 5 amp. supply only electric bell ding-dong ac 230 volt sp with brass screws and cup washers all as specified and directed. pa supply only hylem sheet 3 mm thick size 9" x 11" including cutting of switch,socket complete all as specified supply only hylem sheet 3 mm thick size 8" x 5" including cutting of switch,socket complete all as specified supply only mcb single pole and neutral 32-63 amps, 240 volts, complete all as specified and directed. all as per item ser no 60 above but with two run of single core 6 sq mm and one run of 6 sq mm frlsh as earth wire s&f in replacement of 9 watt led bolard lights 4300/6500 k in rectangular shaped victorian design with opal acrylic diffuser and ip 65 protection,including pcc work for mounting the fittings with suitable size of nut, bolts and connection with two core copper cable all as specified and as directed. make bajaj, havells, crompton. m&l for repair / maint of wooden/steel boards for electrical db of any type and size including replacement of doors as per site requirement, hinges, handle and locking arrangement with necessary welding works, wooden works to make good the wooden / steel boards including painting with synthetic enamel paint of one coat all etc complete. the quoted shall be inclusive of replacement of wooden doors! steel doors/hinges! locking system/welding work required for repair/fixing of new doors etc complete pac s&f in replacement of 36w led recessed 2x2 luminaire 6500k fixed in the existing ceiling/roofs white powder coated crca housing with led seanless front frame with flat white transmission acrylic cover and necessary connection with twin core copper cable of suitable size in kutch auditorium with ceiling height of more than 20 feet including necessary arrangement for scaffolding ladder for replacement of ceiling lights all as specified and as directed. note: the quoted rates are inclusive of necessary safety arrangements iscaffolding/ladder etc complete all as specified and directed
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For providing, erecting, and fixing electricpoles accessories at jawahar navoday vidyalay to samsan, shitla mata temple to bhavani mata temple and hanuman temple senjari school connected to bucharwada main road village roads k road u and road aa1 in diu
Tender For supply of disconnecting and earthing device, 8 pole, 2 way, no off on load 63a, 750 v ac (1000v- insulation), 2no+2nc with heavy duty handle & pad locking arrangement in earth position, mounted in a stainless steel enclosure, suitable for ac-23 duty confirming to is 13947/iec 947 as per edts-355, rev-01, amendment-1 to schaltbau cat. no. m137.0827407 and l&t cat. no. 73342slb321 06b only acceptable. [ warranty period: 30 months after the date of delivery ] ]