Get complete information related to latest Electric Starter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electric Starter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electric Starter Tenders.
Tender For corrigendum : supply of spares of field switches for drills e e - shunt trip coil assembly, part no - v0021 , electrical release coil assly, part no - v0022 , aux. switch assy, part no - v0024 , soloinoid coil for closing mechanism, part no - v0025 , antipumping realy for solinoid, part no - v0026 , closing contactor for solenoid, part no - v0027 , flex connector, part no - v0028 , support insulator single hole for vcb, part no - v0031 , secondry plug and socket, part no - v0032 , fibre glass barrier set for fixed type v, part no - v0039 , drive insulator for vcb, part no - v0041 , vacuum interrupter, part no - v0048 , vacuum circuit braker assly. vcb9576, part no - vfs0062 , indicating lamp, part no - p0043 , trip neutal close switch, part no - p0045 , rectifire capacitor, part no - p0048 , earth leakage relay, part no - p0049 , over current relay single pol, part no - p0050 , resin cast core balance transformer, part no - p0051 , potential transformer 11 kv 110 v,100, part no - p0053 , resin class ct class isp10 ci10, part no - p0056 , 6.6 kv plug complete, part no - p0064 , 6.6 kv socket insulator, part no - p0065 , idmt relay, part no - p0083 , motor protection relay, part no - fsv00121 , ht hrc fuse for p.t., part no - fsv00110 ) /bid number : gem/2026/b/7522304 * /dated: 09-05-2026 & & / bid document 1 / 32
Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electricstarter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti
Tender For auction sale of others - total qty.= 14 nos., description: - 220 kv double pole sf6 circuit breaker, make:abb - 2 nos., 220 kv current transformer, make:bhel - 2 nos., 25 kv single pole cb make:cgl - 2 nos., 25 kv interrupter make:alind - 1 no., p.t. type-i, 25 kv - 7 nos. (remarks - material to be sold on as is where is basis and will be delivered in numbers).