Web Analytics Made Easy - StatCounter

Electric Water Heater Tenders

Get complete information related to latest Electric Water Heater Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electric Water Heater Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electric Water Heater Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45722569 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For supply of electric ceiling fan (v4) isi marked to is 374 , stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 , automatic line voltage correctors (step type) for domestic use (stabilizer) conforming to is 8448 , propeller type ac ventilating fans (exhaust fan) (v3) conforming to is 2312 , exhaust fan pvc body 12" (300mm) sweep 230v, 50 hz , desert cooler bode size 48 inch (hight) , made from gi sheet

CTN :45635667 Due date: 03 Jul, 202603 Jul, 2026 6.08 Lacs
Tender For corrigendum : supply of split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , household refrigerating appliances as per is 17550 (q2) , stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 (q2) , washing machine - domestic purpose (q2)

Central Government/Public Sector

CTN :45723579 Due date: 21 Jul, 202621 Jul, 2026 25.44 Lacs
Tender For special repair of lt overhead acsr conductor to underground cable perimeter security light at 10 compo 19 idsr and provn of 01x hot water plant and electric water heater appliances for offr mess/living at 519 asc bn at pattan under ge 969 ews

Central Government/Public Sector

CTN :45478838 Due date: 14 Jul, 202614 Jul, 2026 2.54 Crore
Location: Goa - Goa Goa - Goa
Tender For corrigendum : provision of electrical equipment against ber equipment held on charge of ge i cg goa - taking down existing industrial socket, indoor/outdoor unit of split type acs of any capacity and size with voltage stabiliser etc. contractor will carefully remove the aforesaid equipment from site and deposit to mes store under age e/m goa complete all as specified and directed., taking down old aluminium/copper sub main wiring of any type and capacity incl. all accessories and all as directed. note : (i) old dismantled wiring and accessories will be contractors property and credit will be charged against schedule of credit., supply and fix split air conditioner inverter type unit wall mounted, high wall split units indoor & outdoor complete with provision of cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with bee 5 star rated and capacity 1.5 tr, single phase 240 volts, 50 hz complete all as directed by engr-in-charge. make: voltas, lg, bluestar, hitachi., supply and fix split air conditioner inverter type unit wall mounted, high wall split units indoor & outdoor complete with provision of cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with bee 5 star rated and capacity 2.0 tr, single phase 240 volts, 50 hz complete all as directed by engr-in-charge. make : voltas, lg, bluestar, hitachi., supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of 2.5% and of capacity 4 kva. make: v-guard, luminious, microtek., supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of 2.5% and of capacity 5 kva. make: v-guard, luminious, microtek., m & l for sub main wiring with two runs of single core 4 sqmm frls copper conductor pvc insulated unsheathed cable as per is 694-1990 (third revision) drawn through & incl casing and caping of suitable size with all accessories such as tees, elbows,couplings, junction boxes etc, as required fixed on wall along with one run of 4 sqmm single core frls insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. note : (i) two runs of phase & neutral wire, one run of earth continuity conductor cable and one run of casing & capping will be measured as one unit for payment purpose.(ii) the wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads., s & f single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole c series mcb 20 amps complete all as specified., supply and fix refrigerators not less than 310 litres, electric driven (single phase), bee 5 star rate with the following features i.e frost free, double door, auto defrost to stop ice builtup, adjustable temperature controller, double door with separate compartment for freezer inverter type compressor with energy efficiency of 5 star rating, tuffened glass shelf complete with an overall product warranty of one year & 10 year on compressor complete including all as specified and directed. note - old removed item shall be deposited in mes store., supply and fix electric water heater, storage type fibre body with copper heating element upto 2 kw capacity 25 litre, bee 5 star rated complete with all accessories such as safety valve, thermostate, nrv, pvc connection pipe and plug top 15 amps etc. including taking out unserviceable one complete all as specified and directed. note - old removed geyser shall be deposited in mes store. make orient cat

State Government

CTN :45452631 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For corrigendum : supply of electric ceiling fan (v4) isi marked to is 374 (q2) , stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 (q2)

CTN :45452736 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For bid to ras corrigendum : supply of split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , drinking water coolers (v4) isi marked to is 1475 (q2) , ceiling fan , exhaust fan , wall mounted fan , refrigerator 310 ltr , voltage stabilizar , electric water heater

CTN :45696125 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For supply of equipment for mechanical engineering department - supply of equipment for mechanical engineering department, lathe machine :specification :bed: 2v & 2 flat, induction hardened and ground minimum bed length: 1375 mm bed width: 240 mm capacity: height of centre: 165 mm swing over bed: 320 mm swing over gap: 510 mm swing over cross slide: 180 mm distance between centres: 650 mm slides: cross slide travel: 200 mm compound slide travel: 115 mm spindle: spindle bore: 40 mm spindle nose: thread type, 62 mm spindle taper: mt-3 tail stock: quill diameter: 38.1 mm taper: mt-3 travel: 120 mm speed: no. of speeds: minimum 8 range: (40 800 )rpm threading: metric: (1 6 )mm (min 13 steps) english: (2 24 )tpi (min 19 steps) lead screw: (1 4) tpi electrical: motor: 1.5 hp, 230v/415v, 50 hz drive: v-belt structure: bed: close-grained cast iron (fg 260) gears: hardened steel base: rigid cast iron stand , open cup apparatus :specification :standard compliance: astm d92 / is 1448 (part 69) test method: open cup flash and fire point determination test cup: brass, precision machined with heat resistant handle heater: electric heater (1000 w 10% nickel chromium) with variable control heating rate: 5 6 c per minute (as per standard) temperature range: -6 to 400 c thermometer: astm 11c or equivalent flame applicator: gas test flame with fine control valvebody: stainless steel housing display: analog / digital temperature indicator power supply: 230v ac, 50 hz safety: overheat protection heat insulation , closed cup apparatus :specification :standard compliance: astm d93 / is 1448 (part 21) test cup:brass cup diameter: 50.7 50.8 mm capacity: minimum 70 ml stirring system heater: electric heater 650 w 10% heating rate: 1 12 c/min adjustable ignition: pilot flame with automatic shutter mechanism temperature measurement: thermometer or digital sensor(ip-28c or astm) display: digital temperature display power supply: 230v ac, 50 hz safety:over-temperature cut-off flame safety control , tail stock assembly :specification :medium-duty tailstock assembly for dismantling & assembly quill stroke: minimum 75 mm taper: mt-3 (preferred standard) feed: hand wheel operated features: set-over screws for taper turning spindle locking arrangement body: cast iron (fg 260) spindle: hardened steel, slip gauge :specification :set size: m87 (87 pieces) or equivalent range: 1.001 mm to 100 mm step sizes: 0.001 mm 0.005 mm 0.01 mm material: high-grade alloy steel / tungsten carbide (preferred) hardness: hrc 63 65 accuracy: grade: grade 1 or grade 2 flatne flatness / parallelism: 0.5 m stored in protective wooden boxes to prevent wear; calibration grades include charts for exact sizes , dc motor:specification :type: dc shunt motor (dismantling model) power: minimum 0.5 hp voltage: 220 v dc speed: 1500 rpm poles: 4 pole construction: laminated stator salient poles accessible armature features: cut section / open type suitable for dismantling and reassembly, hydraulic cylinder :specification :bore diameter: 50 mm stroke length: 250 mm working pressure: 160 bar cylinder tube: honed steel piston rod: hard chrome plated seals: standard industrial seals end caps: steel calibration grades include charts for exact sizes supply: mounted on training base suitable for dismantling and inspection , hydraulic operated directional control valves (dcv):specification :type: manual spool type dc valve configuration: 4/2 way size: ng06 (cetop 3) rated pressure: 210 bar flow capacity: 20 40 lpm body: hardened steel / cast steel spool: ground and hardened ports: clearly marked (p, a, b, t) supply: mounted on training plate suitable for dismantling and study , bearing with shaft assembly :specification :bore diameter: 50 mm stroke length: 250 mm working pressure: 160 bar cylinder tube: honed steel piston rod: hard chrome plated seals: standard industrial seals end caps: steelsupply:mounted on training base suitable for dismantling and inspection , coupling unit using driving and dr

CTN :45689212 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of sponge forcep , mayo scissor , dissecting scissor , deaver scissor , roller bandage , heating pad , mackintosh sheet , iv stand , infrared lamp , surgical tray , ecg gel , digital thermometer , digital blood pressure machine , ecg paper roll , hospital bed sheet with pillow cover , crepe bandage , philadelphia cervical collar , antimicrobial hand wash , disposable syringe 5 ml

CTN :45437069 Due date: 27 Jun, 202627 Jun, 2026 NA
Tender For bid to ras supply of electrical items -good to match with existing surface complete all as specified and directed by eic , supply and fixing in repair modular metal flush box of 4 module with white cover plate including , supply and fixing in repair modular metal flush box of 6 module with white cover plate , material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick , supply and fixing of led wall light bed side light fitting for study table including 3 watt led, aluminium body, , supply only inner container ss or as per sample suitable for vertical type geyser 50 itrs storage capacity , supply only inner container ss or as per sample suitable for vertical type geyser 25 itrs storage capacity , supply only in repair thermostat 0-75 degree as per exiting size as per oems specifications complete all as specified and directed , supply only in repair heating clement 1.5 kw, as per oems specifications all as specified and directed , supply only in repair heating element 2 kw, as per oems specifications all as specified and directed , supply only indicator lamp with flexibe copper wire of suitable size red by green , supply and fixing pvc connection with steel reinforced pipe for hot water connection of size 18 inches x 1 by 2 inches , supply only apperture plate ss suitable for 25 by 50 itrs geyser along with rubber gasket, nuts, bolts, etc , supply and fixing in repairs plug top 15 by 16 amps suitable for geyser socket outlet complete all as specified and as directed , supply and fixing in repair stop valve but fancy type, chromium plated, screwed down cp of size 15 mm fancy type complete all as specified and directed. , supply and fixing in repair bib taps, cast copper alloy with butterfly handle, screwed down, screwed for iron pipe , supply and fixing of solar collector plate panel as per existing size, specification and make of capacity upto 200 lpd , supply and fixing of solar water heater tank as per existing size, specification and make of capacity upto 300 lpd , supply and fixing of cimfr certified led fiame proof batten suitable for single t8 tube of 20 watt, ip 65 protected , supply and fixing cimfr certified led flame proof bay light, 60 watt, well glass in die cast al housing with heat resistant toughened glass, ip 65 protected. 240 volt, , supply and fixing of flame proof weather proof rotary switch with cable termination box in lm 6 aluminium allcy housing single pole 16 amp, 250 volts , supply and fixing of flame proof-weather proof switch socket and plug combined 16 a, 250 v 2p plus earth , supply and fixing of flame proof weather proof switch socket and plug combined 32 a, 500 v 4p plus earth , supply and fixing of flame proof weather proof metallic hose conduit 3 by 4 inches dia, m20 by 3 by 4 inches conduit mxm by fm x m by fx f 3 by 4 inches dia 300 mm long , supply and fixing of flame proof weather proof metallic hose conduit 3 by 4 inches dia, m20 by 3 by 4 inches conduit mxm by fmxmfxf 3 by 4 inches dia 500 mm long , taking down copper by aluminium point wiring light, fan, socket or power complete, including fixture and fittings , supply and fixing for concealed conduit for one light point wiring with 1.5 sqmm nominal cross-sectional area pvc insulated unsheathed single core copper cable working voltage 1100 volts grade , supply and fixing for concealed conduit for one light point wiring with 1.5 sqmm pvc single core cable for one ceiling fan by exhaust fan point controlled by one, one way switch and regulator , supply and fixing for concealed conduit for one light point wiring 1.5 sqmm pvc single core cable for one 3 point 5 amps switch socket outlet point controlled by one switch on the same board. , supply and fixing for concealed conduit for //bid details 3 / 81 one light point wiring with 1.5 sqmm pvc single core cable for one 3 pin 5 amps switch socket outlet point controlled by one switch on independent board. , supply and fixing for concealed conduit for

CTN :45659459 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For supply of stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2)
 Loading, Please wait...

Connect us via What's Up