Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For repair maintenance of electrical, mechanicalservices in various residential building at lok niwas marg , lg secretariate under m-4512 (sh- comprehensive maintenance of 8 passenger hydraulic lift installed at honble lg residence).
Tender For bid to ras supply of m and l in repair for heat shrinkable straight through jointing kit , supply laying in repairs in trenches ducts fixing , taking out carefully cable covers and ht cable from excavated , relaying of ht cable of size 120 sqmm 3 core in trench , excavation in trenches not exceeding 1.5 mtr wide and 1.5 mtr depth , excavation in trenches not exceeding 1.5 mtr wide and depth , removing excavated materials not exceeding 50 m and depositing where directed , returning filling including spreading levelling watering and well ramming , supply and lay sand cushioning to underground ht cable complete , supply and lay reinforced precast concrete cable cover , lay only precast concrete cover size 450 230 50mm , m and l gi pipe light grade with all fittings , m and l for pcc type c2 40 mm graded stone , s and f of dgset 500 kva 3 phase with cpcb iv norms , xlpe pvc insulated cable 3.5 core 300 sqmm , m and l gi pipe light grade with all fittings complete , earthing with gi earth plate electrode 60 60cm 6 mm buried , taking out carefully existing ber dg set from ekm complex area * /bid number : gem/2026/b/7625309 + /dated: 16-06-2026 ' ' / bid document 1 / 21
Tender For repair maintenance of various electricalmechanicalservices at d c office old gargi college building lajpat nagar iv new delhi sh annual comprehensive maintenance of video wall and led display board at dc office lajpat nagar sdm office kalkaji
Tender For 1 repair maintenance of ei fans psets, wet risersub stn pumps,dg set, acequipments central ac plant system at aaagh 2.rmo electricalmechanicalservices at stc-9, metcalfe road, delhi. 3.rmo specialized electricalmechanical works at au tibbia
Tender For running maintenance , operation of electricalmechanicalservices, pump set, diesel generator set , passenger lift installed at college of art, tilak marg, new delhi (sh- comprehensive maintenance of 8 passenger aircon make lift).
Tender For running maintenance , operation of electrical , mechanicalservices, pump set, diesel generator set , passenger lift installed at college of art, tilak marg, new delhi (sh - comprehensive maintenance of kone make 2 nos. passenger lifts).
Tender For (1) running maintenance , operation of electrical , mechanicalservices, pump set, diesel generator set , passenger lift installed at college of art, tilak marg, new delhi (2) maintenance of electrical installation , fans, repair maintenance of a/c equipment, pump set at bungalow of senior officers , ministers resi