Get complete information related to latest Electrical Cabinet Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrical Cabinet Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrical Cabinet Tenders.
Tender For auction sale of depot ferrous scrap - junk (low qualtiy) 98090800 m.s. junk / kachara (low quality): scrap released consisting mainly of low-grade, assorted and mixed mild steel junk (kachara) generated from various railway activities including pressed and empty paint/oil drums,fire extinguish with or without powder,grease manual pump,fan blade,tubelight patti,small paint drum (may be tin ), damaged filters and filter frames, ducts, ms sheet, grills, sliding channels, scrap panels, broken housings, earthing wire,galvanized iron sheet, cabinets and almirah parts, lockers, racks, benches, trays, boxes, covers, frames, brackets, ladders, pipes, rods, bars, wire mesh, mesh guards, grills, scrap sheets, angles, channels, booms, posts, discarded machine parts, miscellaneous fabricated structures, signal and electricalcabinets, dp/mldb boards, relay/telecom racks in scrap condition, cable trays, junction/location boxes, display boards, indicator housings, transformer fittings, tu/dac/aws covers, brake related scrap, air filter assemblies, pantograph related scrap parts, trolleys, damaged hand tools, crane and track machine scrap parts, hydraulic components in scrap condition, racks, ballast tools, scrap furniture,ci pipe , bed and seat frames, cupboards, doors, bins, chains, nuts, bolts and mixed hardware; material is highly rusted, bent, broken, corroded and mixed with mud, dust, grease, paint or oil residues and environmental deposits; all items are unserviceable, obsolete and beyond economical repair (ber); minor non-ferrous, rubber, plastic, insulation, rexine or wooden attachments may be present without segregation; this lot is low quality junk kachara, not identifiable item-wise and not fit for railway use; no claim shall be entertained regarding quantity, composition, quality or recoverability,sold strictly on %u201cas is where is%u201d basis; loading by purchaser, mechanized loading permitted, mud, rust, debris and all remains shall form part of the lot; custodian: dms/scrap/pardi
Tender For supply of smps based integrated power supply (ips) system for lc gate and auto relay hut/line side cabinet with aftc/axle counter/msdac as per rdso spec. no. rdso/ spn/165/2023 version 4.0 with amendment-1, along with surge protection device, status monitoring panel, spares, tool kit, lmla battery 110v/500 ah consisting of 55 + 5 cells (cells as per rdso spec. irs: s-88/2004) alongwith battery stand. the configuration of ips should be as per attached drawing of nwr. this includes transportation to consignee depot to site, commissioning of integrated power supply system after duly filling pre-commissioning check list jointly by rdso approved vendor and railway representative. installation is required. ]
Tender For tender document for supply of office/hospital furniture executive chair , table , wooden chair , revolving stool (high desk to see microscope) , executive table with draw system (48 " 42") , executive chair without head rest , plastic chair for patient with arm , foot steps (prestige) , 500mm (l) x 300mm (w) x 230mm (h) anti slip aluminum trade plate , wooden height chair , wooden chair with cushion without arm and with back rest. width 18" height 36" , adjustable steel rack 3 self , steal rack height 36" length 36" width 10" , medicine storage box , plastic container & partition box (4/6 partition) , plastic rack for file , plastic cupboard 4 self , (4' x 2') , - , computer table , height 30" x length 36" x width 24" with key board, depu & ups stand, draw , eye department , waiting chair 3-seater , high back chair , high back with breathable mesh. , auto-adjustable , 3d adjustable soft pu padded armrests , visitor chair , mid-back visitor chair with contoured lumbar support. , powder-coated mild steel frame for stability. , 1.2 0.1 cm thick hot-pressed plywood with moulded polyurethane (pu) foam. , approximately 47.5 cm (w) x 58 cm (h) (back), 47 cm (w) x 48 cm (d) (seat). , fixed loop arms , almirah storwel plain , (1981 h x 916 w x 486 d) , drawer filling cabinet , (1320 h x 470 w x 620 d) , pedestal dustbin
Tender For supply of electricalcabinet : : - supply installation cooling split ac1 pont 5 ton location 1 , supply installation cooling split ac1 pont 5 ton location 2 , supply installation cooling split ac1 pont 5 ton location 3 , supply installation cooling split ac1 pont 5 ton location 4 , suupply installation stablizer for split ac 1 point 5 ton all location , suupply installation ac for all location
Tender For supply of materials and erection for shifting of control room pannel at 33/ 11 kv sub station bharsawa distt. kaushambi under deposit scheme on "semi turnkey basis" under edc, kaushambi - name of work: supply, carriage & erection of materials for control room pannel shifting of shiffting of 33/11 kv s/s bharsawa distt. kaushambi, supply of de-centralised materials, 11 kv 3x120 mm2 xlpe cable jointing kit o/d & i/d, control cable 4x2.5 mm2, control cable 2x2.5 mm2, g.i. pipe 6 " dia, rubber matting, clamp with nut & bosts, earth wire clamp for pcc pole, stay clamp for pcc pole, top channel clamp pcc pole, dropper channel clamp pcc pole, g.i. strip 35x6 mm, carriage of following material, pcc pole 8.5 mtr. long., structure of la, 33kv isolator, 33 kv cts, single t/f control pannel, 33kv vcb,11 kv outgoing. incoming pannel, battery & battery charger and other associated accessiories etc. (availibility at concern store center of store division), erection work, installation of 33 kv single transformer control pannel 2 no., incoming 2 no. and 7 no. outgoing in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel. all material will be provided by the contractor except vcb and crp., construction of cable trenchs with top cover and laying of control cable for vcb, c.t. & t/f control pannel etc. as per direction of engineer. trenchs to be 12 wide and 9 deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9 wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. all material will be provided by the contractor., earthing of 11 kv indoor equipments, switchgears as per resspo drawing. with g.i. strip of size 35x6 mm. g.i. strip fully welded at both ends and to be connected with earthmat,, erection of dp with pcc pole 8.5 mtr long with all accessaries and grouting of the pcc pole with cement, sand and brick ballast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res-6.(cement, sand, brick, ballast shall be provided by the contractor.), installation of 24 volt battery and battery charger with cabinet in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of rag bolt., laying of 11 kv 3x300/3x185/ 3x120 sqmm. xlpe cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor., fixing and termination of outdoor/ indoor heat shrinkable cable boxes of size 3 x300/3x185/3x120 sqmm. xlpe cable. boxes will be supplied by the contractor, sundries ( as per site requirement/emergency work), safe dismantling of 11 kv o/g pannel & received back to store, laying of weasel conductor with the help of aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of weasel conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support. all material shall be provided by contractor such as jointing sleeve binding wire, armour rod etc.